mf-msmf050-40x-2-hero.glb⋯ 1 unchanged line ⋯
mf-msmf050-40x-2-hero.overlay.json+3−3@@ -66,14 +66,14 @@ "seating_z_mm": 0.0 }, "sources": {- "glb": "mf-msmf050-etched.glb",- "glb_sha256": "63c6d0106fb44b4d05570256b4a49ba409a87ddadeb580fbc85997d52473c238",+ "glb": "mf-msmf050.glb",+ "glb_sha256": "ce6b7f4da12b96e1f3b08dbe878fde6f04e7492e8ee0a15247d1c72facdf1294", "footprint": "mf-msmf050.kicad_mod", "footprint_sha256": "b2bd7adcbcc58fa3957f88eedc5c2c057055a8e1737142fc9ffea5afdb68f6e3", "pins": "page.json component.pins", "pins_sha256": "f89b6cef1dd40bf094bc57ef23dc246a408922a81bfac75b8bc341584ea4e214" },- "generator": "adom-wiki 1.8.22 (component_hero)",+ "generator": "adom-wiki 1.8.25 (component_hero)", "labels": [ { "pad": "1",
package.json+287−4@@ -1,6 +1,6 @@ { "slug": "mf-msmf050-40x-2",- "version": "0.1.1",+ "version": "0.1.2", "type": "component", "description": "BOURNS Resettable Fuses, 1812. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -29,8 +29,6 @@ "viewers/footprint.html", "mf-msmf050-hero.glb", "mf-msmf050-hero.overlay.json",- "mf-msmf050-etched.glb",- "mf-msmf050-etched.step", "mf-msmf050-40x-2-hero.glb", "mf-msmf050-40x-2-hero.overlay.json" ],@@ -164,5 +162,290 @@ "note": "renamed from the cut-base slug to the part it was built from (slug collision split, 2026-11-11)" } },- "visibility": "public"+ "visibility": "public",+ "title": "MF-MSMF050/40X-2",+ "brief": "BOURNS Resettable Fuses, 1812. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "BOURNS",+ "Package": "1812",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "f1803fa6e8d6dd9a451073c7e1c72193c7ea7905fbe8007dbc11b5023a0d0aa7",+ "rows": [+ {+ "name": "Maximum voltage (Vmax, rated voltage)",+ "symbol": "Vmax",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 15,+ "conditions": "",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum interrupt current (Imax)",+ "symbol": "Imax",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 100,+ "conditions": "",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Resistance minimum (Rmin)",+ "symbol": "Rmin",+ "kind": "electrical",+ "unit": "Ω",+ "min": 0.15,+ "typ": null,+ "max": null,+ "conditions": "at 23 °C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Resistance maximum (R1max)",+ "symbol": "R1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "at 23 °C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum time to trip",+ "symbol": "",+ "kind": "electrical",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 0.15,+ "conditions": "at 8.0 A, 23 °C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Operating temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Recommended storage temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "70 % R.H. max.",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Passive aging resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 °C, 1000 hours; typical resistance change",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Humidity aging resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85 °C, 85 % R.H., 1000 hours; typical resistance change",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Thermal shock resistance change",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -10,+ "typ": null,+ "max": 10,+ "conditions": "-40 °C to +85 °C, 20 times; typical resistance change",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current",+ "symbol": "Ihold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "at 23 °C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current",+ "symbol": "Itrip",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 1,+ "max": null,+ "conditions": "at 23 °C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Tripped power dissipation",+ "symbol": "",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.8,+ "max": null,+ "conditions": "",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current derating at ambient -40 °C",+ "symbol": "Ihold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.77,+ "max": null,+ "conditions": "ambient -40 °C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current derating at ambient -20 °C",+ "symbol": "Ihold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.68,+ "max": null,+ "conditions": "ambient -20 °C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current derating at ambient 0 °C",+ "symbol": "Ihold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.59,+ "max": null,+ "conditions": "ambient 0 °C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current derating at ambient 23 °C",+ "symbol": "Ihold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "ambient 23 °C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current derating at ambient 40 °C",+ "symbol": "Ihold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.44,+ "max": null,+ "conditions": "ambient 40 °C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current derating at ambient 50 °C",+ "symbol": "Ihold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.4,+ "max": null,+ "conditions": "ambient 50 °C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current derating at ambient 60 °C",+ "symbol": "Ihold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.37,+ "max": null,+ "conditions": "ambient 60 °C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current derating at ambient 70 °C",+ "symbol": "Ihold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.33,+ "max": null,+ "conditions": "ambient 70 °C",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current derating at ambient 85 °C",+ "symbol": "Ihold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.29,+ "max": null,+ "conditions": "ambient 85 °C",+ "source_page": 4,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "mf-msmf050"+ ],+ "discovery_pitch": "MF-MSMF050 (BOURNS) component page: datasheet pinout, KiCad symbol, footprint and 3D." }
page.json+2−4@@ -4,7 +4,7 @@ "slug": "mf-msmf050-40x-2", "title": "MF-MSMF050/40X-2", "brief": "BOURNS Resettable Fuses, 1812. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.1",+ "version": "0.1.2", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -456,12 +456,10 @@ "viewers/footprint.html", "mf-msmf050-hero.glb", "mf-msmf050-hero.overlay.json",- "mf-msmf050-etched.glb",- "mf-msmf050-etched.step", "mf-msmf050-40x-2-hero.glb", "mf-msmf050-40x-2-hero.overlay.json" ], "visibility": "public", "description": "BOURNS Resettable Fuses, 1812. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "org": "adom"-}+}