← Commit history

Set visibility: public

Ray ·904f5997b6 ·26d ago ·parent 061fef7
1 file changed +11−8
page.json+11−8
@@ -56,37 +56,37 @@         "number": "5",         "name": "PB1",         "type": "passive",-        "description": "Potentiometer 1 Terminal B connection. No polarity restriction versus PA1/PW1; nominal end-to-end resistance PA1-PB1 = 10 k\u03a9. Voltage on this terminal must be within VSS to VDD."+        "description": "Potentiometer 1 Terminal B connection. No polarity restriction versus PA1/PW1; nominal end-to-end resistance PA1-PB1 = 10 kΩ. Voltage on this terminal must be within VSS to VDD."       },       {         "number": "6",         "name": "PW1",         "type": "passive",-        "description": "Potentiometer 1 Wiper connection. Wiper position (0..255) is controlled via SPI; wiper resistance RW \u2248 52 \u03a9 typical at code 00h, VDD = 5.5V. Max wiper current IW = \u00b11 mA."+        "description": "Potentiometer 1 Wiper connection. Wiper position (0..255) is controlled via SPI; wiper resistance RW ≈ 52 Ω typical at code 00h, VDD = 5.5V. Max wiper current IW = ±1 mA."       },       {         "number": "7",         "name": "PA1",         "type": "passive",-        "description": "Potentiometer 1 Terminal A connection. Opposite end of the 10 k\u03a9 resistor array from PB1. In shutdown mode this terminal is open-circuited from the resistor stack."+        "description": "Potentiometer 1 Terminal A connection. Opposite end of the 10 kΩ resistor array from PB1. In shutdown mode this terminal is open-circuited from the resistor stack."       },       {         "number": "8",         "name": "PA0",         "type": "passive",-        "description": "Potentiometer 0 Terminal A connection. One end of the 10 k\u03a9 resistor array for channel 0. In shutdown mode this terminal is open-circuited from the resistor stack."+        "description": "Potentiometer 0 Terminal A connection. One end of the 10 kΩ resistor array for channel 0. In shutdown mode this terminal is open-circuited from the resistor stack."       },       {         "number": "9",         "name": "PW0",         "type": "passive",-        "description": "Potentiometer 0 Wiper connection. Wiper position (0..255) is controlled via SPI; wiper resistance RW \u2248 52 \u03a9 typical at code 00h, VDD = 5.5V. Max wiper current IW = \u00b11 mA."+        "description": "Potentiometer 0 Wiper connection. Wiper position (0..255) is controlled via SPI; wiper resistance RW ≈ 52 Ω typical at code 00h, VDD = 5.5V. Max wiper current IW = ±1 mA."       },       {         "number": "10",         "name": "PB0",         "type": "passive",-        "description": "Potentiometer 0 Terminal B connection. Opposite end of the 10 k\u03a9 resistor array from PA0. Voltage on this terminal must be within VSS to VDD."+        "description": "Potentiometer 0 Terminal B connection. Opposite end of the 10 kΩ resistor array from PA0. Voltage on this terminal must be within VSS to VDD."       },       {         "number": "11",@@ -110,7 +110,7 @@         "number": "14",         "name": "VDD",         "type": "power_in",-        "description": "Positive supply input, 2.7 V to 5.5 V single-supply operation. Static supply current is <1 \u00b5A typical; active supply current is ~340 \u00b5A typical at 5.5 V with fSCK = 10 MHz."+        "description": "Positive supply input, 2.7 V to 5.5 V single-supply operation. Static supply current is <1 µA typical; active supply current is ~340 µA typical at 5.5 V with fSCK = 10 MHz."       }     ],     "provenance": {@@ -200,5 +200,8 @@     "docs/mcp42010t-i-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file