← Commit history

Set visibility: public

Ray ·5b2be027d9 ·1mo ago ·parent 2272eb1
1 file changed +6−3
page.json+6−3
@@ -32,7 +32,7 @@         "number": "1",         "name": "VOUT",         "type": "output",-        "description": "Active-low, open-drain reset output. Pulls low when VDD is below the 4.38 V trip point and releases (goes high-impedance) when VDD rises above the threshold plus hysteresis. Requires an external pull-up resistor (typ. 100 k\u03a9); VOL \u2264 0.4 V at IOL = 500 \u00b5A; open-drain leakage IOD \u2248 0.1 \u00b5A."+        "description": "Active-low, open-drain reset output. Pulls low when VDD is below the 4.38 V trip point and releases (goes high-impedance) when VDD rises above the threshold plus hysteresis. Requires an external pull-up resistor (typ. 100 kΩ); VOL ≤ 0.4 V at IOL = 500 µA; open-drain leakage IOD ≈ 0.1 µA."       },       {         "number": "2",@@ -44,7 +44,7 @@         "number": "3",         "name": "VDD",         "type": "power_in",-        "description": "Positive supply and monitored voltage input. Operating range 1.0 V to 5.5 V, absolute maximum 7.0 V. Detector compares this rail against the internal 4.38 V (450 option) trip threshold. Operating current IDD \u2264 1.75 \u00b5A."+        "description": "Positive supply and monitored voltage input. Operating range 1.0 V to 5.5 V, absolute maximum 7.0 V. Detector compares this rail against the internal 4.38 V (450 option) trip threshold. Operating current IDD ≤ 1.75 µA."       }     ],     "provenance": {@@ -130,5 +130,8 @@     "docs/mcp111t-450e-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file