← Commit history

CAD + datasheet + .step

Ray ·413d37808d · ·parent 7042943
1 file changed +195−8
page.json+195−8
@@ -1,8 +1,11 @@ {+  "schema_version": 1,+  "type": "component",   "slug": "max31865",+  "title": "MAX31865 RTD-to-Digital Converter",+  "brief": "Resistance-to-digital converter for PT100/PT1000 RTD temperature sensors, SPI.",   "version": "0.1.0",-  "type": "component",-  "description": "Resistance-to-digital converter for PT100/PT1000 RTD temperature sensors, SPI.",+  "license": "CC-BY-SA-4.0",   "tags": [     "rtd",     "pt100",@@ -12,6 +15,195 @@     "adi",     "tssop-20"   ],+  "component": {+    "mpn": "MAX31865",+    "manufacturer": "Analog Devices",+    "package": "TSSOP-20",+    "pin_count": 20,+    "category": "Sensor",+    "subcategory": "RTD Interface",+    "datasheet": "https://www.analog.com/media/en/technical-documentation/data-sheets/MAX31865.pdf",+    "parts": {+      "symbol": "max31865.kicad_sym",+      "footprint": "max31865.kicad_mod",+      "model_3d": "max31865.glb",+      "model_3d_step": "max31865.step"+    },+    "distributor_links": {},+    "pins": [+      {+        "number": "1",+        "name": "DRDY",+        "type": "output",+        "description": "Active-low, push-pull data-ready output. DRDY goes low when a new conversion result is available in the RTD data register; it returns high after that register is read."+      },+      {+        "number": "2",+        "name": "DVDD",+        "type": "power_in",+        "description": "Digital supply voltage input, 3.0V-3.6V (nominally 3.3V). Bypass to DGND with a 0.1\u00b5F capacitor."+      },+      {+        "number": "3",+        "name": "VDD",+        "type": "power_in",+        "description": "Analog supply voltage input, 3.0V-3.6V (nominally 3.3V). Bypass to GND1 with a 0.1\u00b5F capacitor."+      },+      {+        "number": "4",+        "name": "BIAS",+        "type": "output",+        "description": "Bias voltage output (VBIAS \u2248 2.0V). Provides the bias for the reference and RTD networks; drives up to 5.75mA."+      },+      {+        "number": "5",+        "name": "REFIN+",+        "type": "input",+        "description": "Positive reference-voltage input. Connect to BIAS. Reference resistor (RREF, 350\u03a9-10k\u03a9) is placed between REFIN+ and REFIN-."+      },+      {+        "number": "6",+        "name": "REFIN-",+        "type": "input",+        "description": "Negative reference-voltage input. Reference resistor is connected between REFIN+ and REFIN-."+      },+      {+        "number": "7",+        "name": "ISENSOR",+        "type": "passive",+        "description": "Low side of RREF; connect to REFIN-. Carries the RTD bias current returning through the reference resistor."+      },+      {+        "number": "8",+        "name": "FORCE+",+        "type": "output",+        "description": "High-side RTD drive. Connect to FORCE2 when using the 3-wire connection configuration. Protected to \u00b145V."+      },+      {+        "number": "9",+        "name": "FORCE2",+        "type": "bidirectional",+        "description": "Positive input used in 3-wire configuration only. Tie to FORCE+ for 3-wire RTDs; ground for 2-wire and 4-wire configurations. Protected to \u00b145V."+      },+      {+        "number": "10",+        "name": "RTDIN+",+        "type": "input",+        "description": "Positive RTD sense input. Protected to \u00b145V."+      },+      {+        "number": "11",+        "name": "RTDIN-",+        "type": "input",+        "description": "Negative RTD sense input. Protected to \u00b145V."+      },+      {+        "number": "12",+        "name": "FORCE-",+        "type": "passive",+        "description": "Low-side RTD return. Protected to \u00b145V."+      },+      {+        "number": "13",+        "name": "GND2",+        "type": "power_in",+        "description": "Analog ground. Connect to GND1."+      },+      {+        "number": "14",+        "name": "SDI",+        "type": "input",+        "description": "SPI serial-data input (MOSI). Sampled on the rising edge of SCLK."+      },+      {+        "number": "15",+        "name": "SCLK",+        "type": "input",+        "description": "SPI serial-data clock input."+      },+      {+        "number": "16",+        "name": "CS",+        "type": "input",+        "description": "Active-low chip select. Drive CS low to enable the SPI interface."+      },+      {+        "number": "17",+        "name": "SDO",+        "type": "output",+        "description": "SPI serial-data output (MISO)."+      },+      {+        "number": "18",+        "name": "DGND",+        "type": "power_in",+        "description": "Digital ground."+      },+      {+        "number": "19",+        "name": "GND1",+        "type": "power_in",+        "description": "Analog ground. Connect to GND2."+      },+      {+        "number": "20",+        "name": "N.C.",+        "type": "unconnected",+        "description": "No internal connection. Do not connect."+      }+    ],+    "provenance": {+      "extractor": "ds2sf",+      "datasheet": {+        "url": "https://www.analog.com/media/en/technical-documentation/data-sheets/MAX31865.pdf",+        "pages": 26,+        "sha256": "88f540410eb8c2ac",+        "source_tier": "mfr"+      },+      "cad": "KiCad official (CC-BY-SA 4.0)",+      "pins": {+        "total": 20,+        "described": 20,+        "cites_pages": true,+        "refuses_to_fabricate": true+      }+    },+    "viewers": {+      "symbol": "viewers/symbol.html",+      "footprint": "viewers/footprint.html"+    }+  },+  "metadata": {+    "specs": {+      "Type": "RTD-to-digital converter",+      "Sensors": "PT100 / PT1000 (2/3/4-wire)",+      "ADC": "15-bit",+      "Accuracy": "0.5% of full scale (max)",+      "Interface": "SPI",+      "Fault detection": "Open, short, overvoltage",+      "Supply voltage": "3.0 V to 3.6 V",+      "Operating temperature": "-40 C to 85 C"+    }+  },+  "sections": [+    "hero",+    "viewers",+    "readme",+    "breadcrumbs",+    "info"+  ],+  "discovery_triggers": [+    "RTD to digital",+    "PT100 amplifier",+    "PT1000 interface",+    "precision temperature",+    "platinum RTD"+  ],+  "discovery_pitch": "Turn a PT100 or PT1000 platinum RTD into a precise digital temperature reading over SPI, with fault detection built in.",+  "author": {+    "name": "Ray",+    "email": "[email protected]"+  },   "dependencies": {},   "hero": {     "type": "image",@@ -28,10 +220,5 @@     "docs/max31865-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ],-  "visibility": "public",-  "author": {-    "name": "Ray",-    "email": "[email protected]"-  }+  ] }\ No newline at end of file