← Commit history
package.json+327−4@@ -1,6 +1,6 @@ { "slug": "ltc2451cts8-trmpbf",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Analog Devices Analog To Digital Converters (ADCs), TSOT-23-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "tags": [@@ -29,7 +29,8 @@ "viewers/footprint.html", "ltc2451cts8-trmpbf-hero.glb", "ltc2451cts8-trmpbf-hero.overlay.json",- "ltc2451cts8-trmpbf-etched.glb"+ "ltc2451cts8-trmpbf-etched.glb",+ "ltc2451cts8-trmpbf-etched.step" ], "component": { "mpn": "LTC2451CTS8#TRMPBF",@@ -43,7 +44,7 @@ "symbol": "ltc2451cts8-trmpbf.kicad_sym", "footprint": "ltc2451cts8-trmpbf.kicad_mod", "model_3d": "ltc2451cts8-trmpbf-hero.glb",- "model_3d_plain": "ltc2451cts8-trmpbf-etched.glb",+ "model_3d_plain": "ltc2451cts8-trmpbf.glb", "model_3d_step": "ltc2451cts8-trmpbf-etched.step", "model_3d_step_plain": "ltc2451cts8-trmpbf.step", "lbr": "ltc2451cts8-trmpbf.lbr"@@ -188,5 +189,327 @@ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" } ]- }+ },+ "title": "LTC2451CTS8#TRMPBF",+ "brief": "Analog Devices Analog To Digital Converters (ADCs), TSOT-23-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "Analog Devices",+ "Package": "TSOT-23-8",+ "Category": "Data Converters",+ "Pins": "8"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "5e3eba71951e62a037453278aa6c0355790d797217b99b7bd9931968dfec4a3a",+ "rows": [+ {+ "name": "Integral Nonlinearity",+ "symbol": "",+ "kind": "electrical",+ "unit": "LSB",+ "min": null,+ "typ": 2,+ "max": 10,+ "conditions": "l",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Offset Error 30Hz Mode",+ "symbol": "",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 0.08,+ "max": 0.5,+ "conditions": "l",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Offset Error 60Hz Mode",+ "symbol": "",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 0.5,+ "max": 2,+ "conditions": "l",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Gain Error",+ "symbol": "",+ "kind": "electrical",+ "unit": "% of FS",+ "min": null,+ "typ": 0.01,+ "max": 0.02,+ "conditions": "l",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Conversion Time 30Hz Mode",+ "symbol": "tCONV",+ "kind": "timing",+ "unit": "ms",+ "min": 26,+ "typ": 33.2,+ "max": 46,+ "conditions": "l",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Conversion Time 60Hz Mode",+ "symbol": "tCONV",+ "kind": "timing",+ "unit": "ms",+ "min": 13,+ "typ": 16.6,+ "max": 23,+ "conditions": "l",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "SCL Clock Frequency",+ "symbol": "fSCL",+ "kind": "timing",+ "unit": "kHz",+ "min": 0,+ "typ": null,+ "max": 400,+ "conditions": "l",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Data Hold Time",+ "symbol": "tHD(DAT)",+ "kind": "timing",+ "unit": "µs",+ "min": 0,+ "typ": null,+ "max": 0.9,+ "conditions": "l",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Rise Time for SDA/SCL Signals",+ "symbol": "tr",+ "kind": "timing",+ "unit": "ns",+ "min": null,+ "typ": null,+ "max": 300,+ "conditions": "20 + 0.1CB min, CB in pF (Note 6)",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Fall Time for SDA/SCL Signals",+ "symbol": "tf",+ "kind": "timing",+ "unit": "ns",+ "min": null,+ "typ": null,+ "max": 300,+ "conditions": "20 + 0.1CB min, CB in pF (Note 6)",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Output Fall Time",+ "symbol": "tOF",+ "kind": "timing",+ "unit": "ns",+ "min": null,+ "typ": null,+ "max": 250,+ "conditions": "VIH(MIN) to VIL(MAX), Bus Load CB 10pF to 400pF (Note 6)",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Supply Voltage",+ "symbol": "VCC",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 2.7,+ "typ": null,+ "max": 5.5,+ "conditions": "l",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Supply Current Conversion",+ "symbol": "ICC",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 400,+ "max": 700,+ "conditions": "l",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Supply Current Sleep",+ "symbol": "ICC",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.2,+ "max": 0.5,+ "conditions": "l",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Low Level Output Voltage (SDA)",+ "symbol": "VOL",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 0.4,+ "conditions": "I = 3mA",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Input Leakage",+ "symbol": "IIN",+ "kind": "electrical",+ "unit": "µA",+ "min": -1,+ "typ": null,+ "max": 1,+ "conditions": "0.1VCC ≤ VIN ≤ 0.9VCC",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Capacitance for Each I/O Pin",+ "symbol": "CI",+ "kind": "electrical",+ "unit": "pF",+ "min": null,+ "typ": null,+ "max": 10,+ "conditions": "l",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Capacitance Load for Each Bus Line",+ "symbol": "CB",+ "kind": "electrical",+ "unit": "pF",+ "min": null,+ "typ": null,+ "max": 400,+ "conditions": "l",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "IN DC Leakage Current",+ "symbol": "IDC_LEAK(VIN)",+ "kind": "electrical",+ "unit": "nA",+ "min": -10,+ "typ": 1,+ "max": 10,+ "conditions": "VIN = GND (Note 8)",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "REF+, REF- DC Leakage Current",+ "symbol": "IDC_LEAK(REF+, REF–)",+ "kind": "electrical",+ "unit": "nA",+ "min": -10,+ "typ": 1,+ "max": 10,+ "conditions": "VREF = 5V (Note 8)",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Supply Voltage",+ "symbol": "VCC",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature Range",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Junction Temperature (C/I grade)",+ "symbol": "TJMAX",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "TS8 package, C/I grade",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating Temperature Range LTC2451C",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 70,+ "conditions": "LTC2451C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Thermal Resistance Junction to Ambient (TS8)",+ "symbol": "θJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 140,+ "max": null,+ "conditions": "TS8 package, C/I grade",+ "source_page": 2,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "ltc2451cts8#trmpbf"+ ],+ "discovery_pitch": "LTC2451CTS8#TRMPBF (Analog Devices) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+7−6@@ -4,7 +4,7 @@ "slug": "ltc2451cts8-trmpbf", "title": "LTC2451CTS8#TRMPBF", "brief": "Analog Devices Analog To Digital Converters (ADCs), TSOT-23-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -25,7 +25,7 @@ "symbol": "ltc2451cts8-trmpbf.kicad_sym", "footprint": "ltc2451cts8-trmpbf.kicad_mod", "model_3d": "ltc2451cts8-trmpbf-hero.glb",- "model_3d_plain": "ltc2451cts8-trmpbf-etched.glb",+ "model_3d_plain": "ltc2451cts8-trmpbf.glb", "model_3d_step": "ltc2451cts8-trmpbf-etched.step", "model_3d_step_plain": "ltc2451cts8-trmpbf.step", "lbr": "ltc2451cts8-trmpbf.lbr"@@ -521,9 +521,10 @@ "viewers/footprint.html", "ltc2451cts8-trmpbf-hero.glb", "ltc2451cts8-trmpbf-hero.overlay.json",- "ltc2451cts8-trmpbf-etched.glb"+ "ltc2451cts8-trmpbf-etched.glb",+ "ltc2451cts8-trmpbf-etched.step" ],- "visibility": {- "public": true- }+ "visibility": "public",+ "description": "Analog Devices Analog To Digital Converters (ADCs), TSOT-23-8. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "org": "adom" }