← Commit history

lt1004cdr-2-5: specified limits as data (metadata.characteristics, 19 rows from the datasheet)

Ray ·21646f4f0c · ·parent 76e34c1
2 files changed +261
README.md+26
@@ -26,6 +26,32 @@ LT1004CDR-2-5 from Texas Instruments, in a SOIC-8. Pinout and pin descriptions e | Category | Power Management (PMIC) | | Pins | 8 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Reference voltage (VZ), 25°C | VZ | 2.48 | 2.5 | 2.52 | V | IZ = 100 µA, TA = 25°C | 4 |+| Reference voltage (VZ), full range LT1004C | VZ | 2.47 |  | 2.53 | V | IZ = 100 µA, full range (0°C to 70°C for LT1004C) | 4 |+| Initial accuracy |  | -20 |  | 20 | mV | LT1004-2.5 initial accuracy (Features list) | 1 |+| Minimum reference current IZ(min) | IZ(min) |  |  | 20 | µA | Full range (0°C to 70°C for LT1004C) | 4 |+| Change in reference voltage with current | ΔVZ |  |  | 1 | mV | IZ = IZ(min) to 1 mA, 25°C | 4 |+| Change in reference voltage with current, full range | ΔVZ |  |  | 1.5 | mV | IZ = IZ(min) to 1 mA, full range (0°C to 70°C for LT1004C) | 4 |+| Change in reference voltage with current | ΔVZ |  |  | 10 | mV | IZ = 1 mA to 20 mA, 25°C | 4 |+| Change in reference voltage with current, full range | ΔVZ |  |  | 20 | mV | IZ = 1 mA to 20 mA, full range (0°C to 70°C for LT1004C) | 4 |+| Long-term change in reference voltage | ΔVZ/Δt |  |  | 20 | ppm/khr | IZ = 100 µA, 25°C | 4 |+| Reference impedance, 25°C | zz |  | 0.2 | 0.6 | Ω | IZ = 100 µA, 25°C | 4 |+| Reference impedance, full range | zz |  |  | 1.5 | Ω | IZ = 100 µA, full range (0°C to 70°C for LT1004C) | 4 |+| Average temperature coefficient of reference voltage |  |  | 20 |  | ppm/°C | IZ = 10 µA, 25°C | 4 |+| Reverse current | IR |  |  | 30 | mA |  | 4 |+| Forward current | IF |  |  | 10 | mA |  | 4 |+| Operating virtual junction temperature | TJ |  |  | 150 | °C |  | 4 |+| Lead temperature |  |  |  | 260 | °C | 1.6 mm (1/16 inch) from case for 10 seconds | 4 |+| Storage temperature range | Tstg | -65 |  | 150 | °C |  | 4 |+| Package thermal impedance, D package | θJA |  | 97 |  | °C/W | D package (see Notes 1 and 2) | 4 |+| Operating free-air temperature, LT1004C | TA | 0 |  | 70 | °C | LT1004C | 4 |+ ## CAD (KiCad official)  - Symbol: `LT1004CDR-2-5`
page.json+235
@@ -140,6 +140,241 @@       "Package": "SOIC-8",       "Category": "Power Management (PMIC)",       "Pins": "8"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "f1e1f2915363f355",+      "rows": [+        {+          "name": "Reference voltage (VZ), 25°C",+          "symbol": "VZ",+          "kind": "electrical",+          "unit": "V",+          "min": 2.48,+          "typ": 2.5,+          "max": 2.52,+          "conditions": "IZ = 100 µA, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reference voltage (VZ), full range LT1004C",+          "symbol": "VZ",+          "kind": "electrical",+          "unit": "V",+          "min": 2.47,+          "typ": null,+          "max": 2.53,+          "conditions": "IZ = 100 µA, full range (0°C to 70°C for LT1004C)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Initial accuracy",+          "symbol": "",+          "kind": "tolerance",+          "unit": "mV",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "LT1004-2.5 initial accuracy (Features list)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Minimum reference current IZ(min)",+          "symbol": "IZ(min)",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "Full range (0°C to 70°C for LT1004C)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Change in reference voltage with current",+          "symbol": "ΔVZ",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "IZ = IZ(min) to 1 mA, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Change in reference voltage with current, full range",+          "symbol": "ΔVZ",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 1.5,+          "conditions": "IZ = IZ(min) to 1 mA, full range (0°C to 70°C for LT1004C)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Change in reference voltage with current",+          "symbol": "ΔVZ",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "IZ = 1 mA to 20 mA, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Change in reference voltage with current, full range",+          "symbol": "ΔVZ",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "IZ = 1 mA to 20 mA, full range (0°C to 70°C for LT1004C)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Long-term change in reference voltage",+          "symbol": "ΔVZ/Δt",+          "kind": "electrical",+          "unit": "ppm/khr",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "IZ = 100 µA, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reference impedance, 25°C",+          "symbol": "zz",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.2,+          "max": 0.6,+          "conditions": "IZ = 100 µA, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reference impedance, full range",+          "symbol": "zz",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 1.5,+          "conditions": "IZ = 100 µA, full range (0°C to 70°C for LT1004C)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Average temperature coefficient of reference voltage",+          "symbol": "",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": null,+          "typ": 20,+          "max": null,+          "conditions": "IZ = 10 µA, 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Reverse current",+          "symbol": "IR",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 30,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Forward current",+          "symbol": "IF",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating virtual junction temperature",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Lead temperature",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "1.6 mm (1/16 inch) from case for 10 seconds",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature range",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Package thermal impedance, D package",+          "symbol": "θJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 97,+          "max": null,+          "conditions": "D package (see Notes 1 and 2)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature, LT1004C",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 0,+          "typ": null,+          "max": 70,+          "conditions": "LT1004C",+          "source_page": 4,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],