← Commit history

lp873344rhdrq1: specified limits as data (metadata.characteristics, 60 rows from the datasheet)

Ray ·a6eb730d34 ·16d ago ·parent eaff1ef
2 files changed +795−1
README.md+67
@@ -47,6 +47,73 @@ LP873344RHDRQ1 from Texas Instruments, in a VQFN-28(5x5). Pinout and pin descrip | Category | Power Management (PMIC) | | Pins | 29 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Voltage on power connections VIN_Bx, VANA (must use same input supply) |  | -0.3 |  | 6 | V | Over operating free-air temperature range | 5 |+| Voltage on power connections VIN_LDOx |  | -0.3 |  | 6 | V | Over operating free-air temperature range | 5 |+| Voltage on buck switch nodes SW_Bx |  | -0.3 |  |  | V |  | 5 |+| Voltage on buck voltage sense nodes FB_Bx |  | -0.3 |  |  | V |  | 5 |+| Voltage on LDO output VOUT_LDOx |  | -0.3 |  |  | V |  | 5 |+| Voltage on logic pins SDA, SCL, nINT, EN |  | -0.3 |  | 6 | V | Input or output pins | 5 |+| Voltage on logic pins PGOOD, GPO, CLKIN (GPO2) |  | -0.3 |  |  | V | Input or output pins | 5 |+| Junction temperature TJ-MAX |  | -40 |  | 150 | °C | Over operating free-air temperature range | 5 |+| Storage temperature Tstg |  | -65 |  | 150 | °C |  | 5 |+| Maximum lead temperature |  |  |  | 260 |  | Soldering, 10 seconds | 5 |+| Input voltage range VIN_Bx, VANA |  | 2.8 |  | 5.5 | V | VIN_Bx and VANA must be connected to the same input supply | 5 |+| Voltage on LDO inputs VIN_LDOx |  | 2.5 |  | 5.5 | V |  | 5 |+| Voltage on logic pins EN, nINT |  | 0 |  | 5.5 | V | Input or output pins | 5 |+| Voltage on logic input pin CLKIN |  | 0 |  |  | V | Input pin | 5 |+| Voltage on logic output pins PGOOD, GPO, GPO2 |  | 0 |  |  | V | Output pins | 5 |+| Voltage on I2C interface SCL, SDA |  | 0 |  | 1.95 | V | Standard (100 kHz), Fast (400 kHz), Fast+ (1 MHz), High-Speed (3.4 MHz) modes | 5 |+| Voltage on I2C interface SCL, SDA |  | 0 |  |  | V | Standard (100 kHz), Fast (400 kHz), Fast+ (1 MHz) modes | 5 |+| Junction temperature TJ |  | -40 |  | 140 | °C |  | 5 |+| Ambient temperature TA |  | -40 |  | 125 | °C |  | 5 |+| Effective output filtering capacitance per phase COUT_BUCK | COUT_BUCK | 10 | 22 | 500 | µF | Effective capacitance per phase | 6 |+| Output filtering capacitance for LDO regulators | COUT_LDO | 0.4 | 1 | 2.7 | µF | Effective capacitance | 6 |+| Inductance of the inductor (tolerance) | L | -30 |  | 30 | % | Printed tolerance –30% / 30% of 0.47 µH | 6 |+| Input voltage range V(VIN_Bx), V(VANA) | V(VIN_Bx), V(VANA) | 2.8 | 3.7 | 5.5 | V | VIN_Bx and VANA pins must be connected to the same supply line | 6 |+| Buck output voltage programmable range | VOUT_Bx | 0.7 | 1 | 3.36 | V | Programmable voltage range | 6 |+| DC output voltage accuracy | VOUT_Bx_DC | -20 |  | 20 | mV | Force PWM mode, VOUT < 1 V | 7 |+| DC output voltage accuracy | VOUT_Bx_DC | -2 |  | 2 | % | Force PWM mode, VOUT ≥ 1 V | 7 |+| DC output voltage accuracy | VOUT_Bx_DC | -20 |  | 40 | mV | PFM mode, VOUT < 1 V, the average output voltage level is increased by max. 20 mV | 7 |+| Transient load step response, single-phase output | TLDSR | -55 |  | 55 | mV | IOUT = 0.1 A to 2 A, TR = TF = 400 ns, PWM mode | 7 |+| Transient load step response, dual-phase output | TLDSR | -50 |  | 50 | mV | IOUT = 0.1 A to 4 A, TR = TF = 400 ns, PWM mode | 7 |+| Forward current limit per phase programmable range | ILIM FWD | 1.5 |  | 4 | A | Programmable range | 7 |+| Forward current limit accuracy | ILIM FWD | -5 | 7.5 | 20 | % | V(VIN_Bx) ≥ 3 V, ILIM = 4 A | 7 |+| Negative current limit per phase | ILIM NEG | 1.6 | 2 | 3 | A |  | 7 |+| Switching frequency | ƒSW | 1.8 | 2 | 2.2 | MHz | PWM mode | 7 |+| Overvoltage threshold for PGOOD and power-good interrupt (buck) |  | 39 | 50 | 64 | mV | V(VIN_Bx), V(VANA) fixed 3.7 V; compared to DC output voltage level VOUT_Bx_DC | 8 |+| Undervoltage threshold for PGOOD and power-good interrupt (buck) |  | -53 | -40 | -29 | mV | V(VIN_Bx), V(VANA) fixed 3.7 V; compared to DC output voltage level VOUT_Bx_DC | 8 |+| Output pulldown resistance (buck) | RDIS_Bx | 150 | 250 | 350 | Ω | Regulator disabled | 8 |+| Buck short-circuit detection threshold |  | 280 | 360 | 440 | mV |  | 9 |+| Input voltage range for LDO power inputs VIN_LDOx | VIN_LDOx | 2.5 | 3.7 | 5.5 | V | VIN_LDOx can be higher or lower than V(VANA) | 8 |+| LDO output voltage programmable range | VOUT_LDOx | 0.8 |  | 3.3 | V | Programmable voltage range | 8 |+| DC output voltage accuracy (LDO) | VOUT_LDO_DC | -20 |  | 20 | mV | VOUT < 1 V | 8 |+| DC output voltage accuracy (LDO) | VOUT_LDO_DC | -2 |  | 2 | % | VOUT ≥ 1 V | 8 |+| Transient load step response (LDO) | TLDSR | -50 |  | 40 | mV | IOUT = 1 mA to 300 mA, TR = TF = 1 µs | 8 |+| LDO current limit | ISHORT(LDOx) | 400 | 500 | 600 | mA | VOUT = 0 V | 8 |+| Output pulldown resistance (LDO) | RDIS_LDOx | 150 | 250 | 350 | Ω | Regulator disabled | 8 |+| LDO short-circuit detection threshold |  | 190 | 300 | 450 | mV |  | 9 |+| External input clock nominal frequency | fEXT_CLK | 1 |  | 24 | MHz | Nominal frequency | 9 |+| Required accuracy from nominal frequency (external clock) | fEXT_CLK | -30 |  | 10 | % |  | 9 |+| Thermal warning threshold (TDIE_WARN_LEVEL = 0) |  | 115 | 125 | 135 | °C | Temperature rising, TDIE_WARN_LEVEL = 0 | 9 |+| Thermal warning threshold (TDIE_WARN_LEVEL = 1) |  | 127 | 137 | 147 | °C | Temperature rising, TDIE_WARN_LEVEL = 1 | 9 |+| Thermal shutdown threshold |  | 140 | 150 | 160 | °C | Temperature rising | 9 |+| VANA overvoltage threshold (rising) | VANAOVP | 5.6 | 5.8 | 6.1 | V | Voltage rising | 9 |+| VANA overvoltage threshold (falling) | VANAOVP | 5.45 | 5.73 | 5.96 | V | Voltage falling | 9 |+| VANA undervoltage lockout (rising) | VANAUVLO | 2.51 | 2.63 | 2.75 | V | Voltage rising | 9 |+| VANA undervoltage lockout (falling) | VANAUVLO | 2.5 | 2.6 | 2.7 | V | Voltage falling | 9 |+| Load current measurement accuracy |  |  |  | 10 | % | IOUT > 1 A per phase; printed as <10% | 9 |+| Input current, all logic inputs | ILEAK | -1 |  | 1 | µA | All logic inputs over pin voltage range | 11 |+| Junction-to-ambient thermal resistance | RθJA |  | 36.7 |  | °C/W |  | 6 |+| Junction-to-case (top) thermal resistance | RθJCtop |  | 26.6 |  | °C/W |  | 6 |+| Junction-to-board thermal resistance | RθJB |  | 8.9 |  | °C/W |  | 6 |+| Junction-to-case (bottom) thermal resistance | RθJCbot |  | 2.2 |  | °C/W |  | 6 |+ ## CAD (KiCad official)  - Symbol: `LP873344RHDRQ1`
page.json+728−1
@@ -307,6 +307,733 @@       "Package": "VQFN-28(5x5)",       "Category": "Power Management (PMIC)",       "Pins": "29"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "5c54b6621e0847f2",+      "rows": [+        {+          "name": "Voltage on power connections VIN_Bx, VANA (must use same input supply)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 6,+          "conditions": "Over operating free-air temperature range",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on power connections VIN_LDOx",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 6,+          "conditions": "Over operating free-air temperature range",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on buck switch nodes SW_Bx",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on buck voltage sense nodes FB_Bx",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on LDO output VOUT_LDOx",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on logic pins SDA, SCL, nINT, EN",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 6,+          "conditions": "Input or output pins",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on logic pins PGOOD, GPO, CLKIN (GPO2)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "Input or output pins",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Junction temperature TJ-MAX",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 150,+          "conditions": "Over operating free-air temperature range",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature Tstg",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Maximum lead temperature",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "Soldering, 10 seconds",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range VIN_Bx, VANA",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 2.8,+          "typ": null,+          "max": 5.5,+          "conditions": "VIN_Bx and VANA must be connected to the same input supply",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on LDO inputs VIN_LDOx",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 2.5,+          "typ": null,+          "max": 5.5,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on logic pins EN, nINT",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": 5.5,+          "conditions": "Input or output pins",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on logic input pin CLKIN",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": null,+          "conditions": "Input pin",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on logic output pins PGOOD, GPO, GPO2",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": null,+          "conditions": "Output pins",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on I2C interface SCL, SDA",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": 1.95,+          "conditions": "Standard (100 kHz), Fast (400 kHz), Fast+ (1 MHz), High-Speed (3.4 MHz) modes",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Voltage on I2C interface SCL, SDA",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 0,+          "typ": null,+          "max": null,+          "conditions": "Standard (100 kHz), Fast (400 kHz), Fast+ (1 MHz) modes",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Junction temperature TJ",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 140,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Ambient temperature TA",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Effective output filtering capacitance per phase COUT_BUCK",+          "symbol": "COUT_BUCK",+          "kind": "electrical",+          "unit": "µF",+          "min": 10,+          "typ": 22,+          "max": 500,+          "conditions": "Effective capacitance per phase",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Output filtering capacitance for LDO regulators",+          "symbol": "COUT_LDO",+          "kind": "electrical",+          "unit": "µF",+          "min": 0.4,+          "typ": 1,+          "max": 2.7,+          "conditions": "Effective capacitance",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Inductance of the inductor (tolerance)",+          "symbol": "L",+          "kind": "tolerance",+          "unit": "%",+          "min": -30,+          "typ": null,+          "max": 30,+          "conditions": "Printed tolerance –30% / 30% of 0.47 µH",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range V(VIN_Bx), V(VANA)",+          "symbol": "V(VIN_Bx), V(VANA)",+          "kind": "electrical",+          "unit": "V",+          "min": 2.8,+          "typ": 3.7,+          "max": 5.5,+          "conditions": "VIN_Bx and VANA pins must be connected to the same supply line",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Buck output voltage programmable range",+          "symbol": "VOUT_Bx",+          "kind": "electrical",+          "unit": "V",+          "min": 0.7,+          "typ": 1,+          "max": 3.36,+          "conditions": "Programmable voltage range",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "DC output voltage accuracy",+          "symbol": "VOUT_Bx_DC",+          "kind": "tolerance",+          "unit": "mV",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "Force PWM mode, VOUT < 1 V",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "DC output voltage accuracy",+          "symbol": "VOUT_Bx_DC",+          "kind": "tolerance",+          "unit": "%",+          "min": -2,+          "typ": null,+          "max": 2,+          "conditions": "Force PWM mode, VOUT ≥ 1 V",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "DC output voltage accuracy",+          "symbol": "VOUT_Bx_DC",+          "kind": "tolerance",+          "unit": "mV",+          "min": -20,+          "typ": null,+          "max": 40,+          "conditions": "PFM mode, VOUT < 1 V, the average output voltage level is increased by max. 20 mV",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Transient load step response, single-phase output",+          "symbol": "TLDSR",+          "kind": "tolerance",+          "unit": "mV",+          "min": -55,+          "typ": null,+          "max": 55,+          "conditions": "IOUT = 0.1 A to 2 A, TR = TF = 400 ns, PWM mode",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Transient load step response, dual-phase output",+          "symbol": "TLDSR",+          "kind": "tolerance",+          "unit": "mV",+          "min": -50,+          "typ": null,+          "max": 50,+          "conditions": "IOUT = 0.1 A to 4 A, TR = TF = 400 ns, PWM mode",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Forward current limit per phase programmable range",+          "symbol": "ILIM FWD",+          "kind": "electrical",+          "unit": "A",+          "min": 1.5,+          "typ": null,+          "max": 4,+          "conditions": "Programmable range",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Forward current limit accuracy",+          "symbol": "ILIM FWD",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": 7.5,+          "max": 20,+          "conditions": "V(VIN_Bx) ≥ 3 V, ILIM = 4 A",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Negative current limit per phase",+          "symbol": "ILIM NEG",+          "kind": "electrical",+          "unit": "A",+          "min": 1.6,+          "typ": 2,+          "max": 3,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Switching frequency",+          "symbol": "ƒSW",+          "kind": "electrical",+          "unit": "MHz",+          "min": 1.8,+          "typ": 2,+          "max": 2.2,+          "conditions": "PWM mode",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Overvoltage threshold for PGOOD and power-good interrupt (buck)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": 39,+          "typ": 50,+          "max": 64,+          "conditions": "V(VIN_Bx), V(VANA) fixed 3.7 V; compared to DC output voltage level VOUT_Bx_DC",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Undervoltage threshold for PGOOD and power-good interrupt (buck)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": -53,+          "typ": -40,+          "max": -29,+          "conditions": "V(VIN_Bx), V(VANA) fixed 3.7 V; compared to DC output voltage level VOUT_Bx_DC",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Output pulldown resistance (buck)",+          "symbol": "RDIS_Bx",+          "kind": "electrical",+          "unit": "Ω",+          "min": 150,+          "typ": 250,+          "max": 350,+          "conditions": "Regulator disabled",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Buck short-circuit detection threshold",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": 280,+          "typ": 360,+          "max": 440,+          "conditions": "",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range for LDO power inputs VIN_LDOx",+          "symbol": "VIN_LDOx",+          "kind": "electrical",+          "unit": "V",+          "min": 2.5,+          "typ": 3.7,+          "max": 5.5,+          "conditions": "VIN_LDOx can be higher or lower than V(VANA)",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "LDO output voltage programmable range",+          "symbol": "VOUT_LDOx",+          "kind": "electrical",+          "unit": "V",+          "min": 0.8,+          "typ": null,+          "max": 3.3,+          "conditions": "Programmable voltage range",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "DC output voltage accuracy (LDO)",+          "symbol": "VOUT_LDO_DC",+          "kind": "tolerance",+          "unit": "mV",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "VOUT < 1 V",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "DC output voltage accuracy (LDO)",+          "symbol": "VOUT_LDO_DC",+          "kind": "tolerance",+          "unit": "%",+          "min": -2,+          "typ": null,+          "max": 2,+          "conditions": "VOUT ≥ 1 V",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Transient load step response (LDO)",+          "symbol": "TLDSR",+          "kind": "electrical",+          "unit": "mV",+          "min": -50,+          "typ": null,+          "max": 40,+          "conditions": "IOUT = 1 mA to 300 mA, TR = TF = 1 µs",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "LDO current limit",+          "symbol": "ISHORT(LDOx)",+          "kind": "electrical",+          "unit": "mA",+          "min": 400,+          "typ": 500,+          "max": 600,+          "conditions": "VOUT = 0 V",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Output pulldown resistance (LDO)",+          "symbol": "RDIS_LDOx",+          "kind": "electrical",+          "unit": "Ω",+          "min": 150,+          "typ": 250,+          "max": 350,+          "conditions": "Regulator disabled",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "LDO short-circuit detection threshold",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": 190,+          "typ": 300,+          "max": 450,+          "conditions": "",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "External input clock nominal frequency",+          "symbol": "fEXT_CLK",+          "kind": "electrical",+          "unit": "MHz",+          "min": 1,+          "typ": null,+          "max": 24,+          "conditions": "Nominal frequency",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Required accuracy from nominal frequency (external clock)",+          "symbol": "fEXT_CLK",+          "kind": "tolerance",+          "unit": "%",+          "min": -30,+          "typ": null,+          "max": 10,+          "conditions": "",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Thermal warning threshold (TDIE_WARN_LEVEL = 0)",+          "symbol": "",+          "kind": "electrical",+          "unit": "°C",+          "min": 115,+          "typ": 125,+          "max": 135,+          "conditions": "Temperature rising, TDIE_WARN_LEVEL = 0",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Thermal warning threshold (TDIE_WARN_LEVEL = 1)",+          "symbol": "",+          "kind": "electrical",+          "unit": "°C",+          "min": 127,+          "typ": 137,+          "max": 147,+          "conditions": "Temperature rising, TDIE_WARN_LEVEL = 1",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Thermal shutdown threshold",+          "symbol": "",+          "kind": "electrical",+          "unit": "°C",+          "min": 140,+          "typ": 150,+          "max": 160,+          "conditions": "Temperature rising",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "VANA overvoltage threshold (rising)",+          "symbol": "VANAOVP",+          "kind": "electrical",+          "unit": "V",+          "min": 5.6,+          "typ": 5.8,+          "max": 6.1,+          "conditions": "Voltage rising",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "VANA overvoltage threshold (falling)",+          "symbol": "VANAOVP",+          "kind": "electrical",+          "unit": "V",+          "min": 5.45,+          "typ": 5.73,+          "max": 5.96,+          "conditions": "Voltage falling",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "VANA undervoltage lockout (rising)",+          "symbol": "VANAUVLO",+          "kind": "electrical",+          "unit": "V",+          "min": 2.51,+          "typ": 2.63,+          "max": 2.75,+          "conditions": "Voltage rising",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "VANA undervoltage lockout (falling)",+          "symbol": "VANAUVLO",+          "kind": "electrical",+          "unit": "V",+          "min": 2.5,+          "typ": 2.6,+          "max": 2.7,+          "conditions": "Voltage falling",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Load current measurement accuracy",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "IOUT > 1 A per phase; printed as <10%",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Input current, all logic inputs",+          "symbol": "ILEAK",+          "kind": "electrical",+          "unit": "µA",+          "min": -1,+          "typ": null,+          "max": 1,+          "conditions": "All logic inputs over pin voltage range",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-ambient thermal resistance",+          "symbol": "RθJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 36.7,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-case (top) thermal resistance",+          "symbol": "RθJCtop",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 26.6,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-board thermal resistance",+          "symbol": "RθJB",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 8.9,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-case (bottom) thermal resistance",+          "symbol": "RθJCbot",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 2.2,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -348,4 +1075,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}