← Commit history

Set visibility: public

Ray ·5aadba79d3 ·4d ago ·parent 93b5d31
1 file changed +6−3
page.json+6−3
@@ -54,7 +54,7 @@         "number": "1",         "name": "EN",         "type": "input",-        "description": "Enable pin allows device to be turned ON and OFF via logic level control, with output disabled when VEN \u2264 0.4 V and enabled when VEN \u2265 VEN(ON) threshold."+        "description": "Enable pin allows device to be turned ON and OFF via logic level control, with output disabled when VEN ≤ 0.4 V and enabled when VEN ≥ VEN(ON) threshold."       },       {         "number": "2",@@ -66,7 +66,7 @@         "number": "3",         "name": "OUT",         "type": "output",-        "description": "Regulated output voltage of 3.3 V with \u00b12.5% tolerance at 25\u00b0C and 1 A maximum continuous output current."+        "description": "Regulated output voltage of 3.3 V with ±2.5% tolerance at 25°C and 1 A maximum continuous output current."       },       {         "number": "4",@@ -158,5 +158,8 @@     "docs/lp38692mpx-3-3-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file