← Commit history
package.json+733−4@@ -1,6 +1,6 @@ { "slug": "lmk00304sq",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Texas Instruments Clock Buffers, Drivers, Distributors, WQFN-32-EP(5x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "tags": [@@ -29,7 +29,8 @@ "viewers/footprint.html", "lmk00304sq-hero.glb", "lmk00304sq-hero.overlay.json",- "lmk00304sq-etched.glb"+ "lmk00304sq-etched.glb",+ "lmk00304sq-etched.step" ], "component": { "mpn": "LMK00304SQ",@@ -43,7 +44,7 @@ "symbol": "lmk00304sq.kicad_sym", "footprint": "lmk00304sq.kicad_mod", "model_3d": "lmk00304sq-hero.glb",- "model_3d_plain": "lmk00304sq-etched.glb",+ "model_3d_plain": "lmk00304sq.glb", "model_3d_step": "lmk00304sq-etched.step", "model_3d_step_plain": "lmk00304sq.step", "lbr": "lmk00304sq.lbr"@@ -336,5 +337,733 @@ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" } ]- }+ },+ "title": "LMK00304SQ",+ "brief": "Texas Instruments Clock Buffers, Drivers, Distributors, WQFN-32-EP(5x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "Texas Instruments",+ "Package": "WQFN-32-EP(5x5)",+ "Category": "Clock/Timing",+ "Pins": "33"+ },+ "appearance": {+ "contacts": {+ "quote": "(1) Any unused output pins should be left floating with minimum copper length (see note in Clock Outputs), or properly terminated if",+ "page": 5,+ "doc": "ds.pdf",+ "material": "copper"+ },+ "version": 1,+ "datasheet_sha256": "0e8ba3d15a7f8248b906d715bef07c70ffddbeb9e6de03d40b91b8a2fdc27666"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "0e8ba3d15a7f8248b906d715bef07c70ffddbeb9e6de03d40b91b8a2fdc27666",+ "rows": [+ {+ "name": "VCC, VCCO Supply Voltages",+ "symbol": "VCC, VCCO",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 3.6,+ "conditions": "over operating free-air temperature range",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Input Voltage",+ "symbol": "VIN",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": null,+ "conditions": "max VCC + 0.3",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature Range",+ "symbol": "TSTG",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Lead Temperature (solder 4 s)",+ "symbol": "TL",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "solder 4 s",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Junction Temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Ambient Temperature Range",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": 25,+ "max": 85,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Junction Temperature",+ "symbol": "TJ",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Core Supply Voltage Range",+ "symbol": "VCC",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 3.15,+ "typ": 3.3,+ "max": 3.45,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-ambient thermal resistance",+ "symbol": "RθJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 38.1,+ "max": null,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-case (top) thermal resistance",+ "symbol": "RθJC(top)",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 7.2,+ "max": null,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Core Supply Current, All Outputs Disabled",+ "symbol": "ICC_CORE",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 8.5,+ "max": 10.5,+ "conditions": "CLKinX selected",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Additive Core Supply Current, LVPECL Banks Enabled",+ "symbol": "ICC_PECL",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 38,+ "max": 48,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Additive Core Supply Current, LVDS Banks Enabled",+ "symbol": "ICC_LVDS",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 43,+ "max": 52,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Additive Core Supply Current, HCSL Banks Enabled",+ "symbol": "ICC_HCSL",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 50,+ "max": 58.5,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Additive Core Supply Current, LVCMOS Output Enabled",+ "symbol": "ICC_CMOS",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 3.5,+ "max": 5.5,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Additive Output Supply Current, LVPECL Banks Enabled",+ "symbol": "ICCO_PECL",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 135,+ "max": 163,+ "conditions": "Includes Output Bank Bias and Load Currents for both banks, RT = 50 Ω to Vcco – 2 V on all outputs",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Additive Output Supply Current, LVDS Banks Enabled",+ "symbol": "ICCO_LVDS",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 25,+ "max": 34.5,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Additive Output Supply Current, HCSL Banks Enabled",+ "symbol": "ICCO_HCSL",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 65,+ "max": 81.5,+ "conditions": "Includes Output Bank Bias and Load Currents for both banks, RT = 50 Ω on all outputs",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Additive Output Supply Current, LVCMOS Output Enabled",+ "symbol": "ICCO_CMOS",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 9,+ "max": 10,+ "conditions": "200 MHz, CL = 5 pF, Vcco = 3.3 V ± 5%",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "High-Level Input Voltage",+ "symbol": "VIH",+ "kind": "electrical",+ "unit": "V",+ "min": 1.6,+ "typ": null,+ "max": null,+ "conditions": "max Vcc",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Low-Level Input Voltage",+ "symbol": "VIL",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 0.4,+ "conditions": "min GND",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Low-Level Input Current",+ "symbol": "IIL",+ "kind": "electrical",+ "unit": "µA",+ "min": -5,+ "typ": 0.1,+ "max": null,+ "conditions": "VIL = 0 V, Internal pulldown resistor",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Input Frequency Range",+ "symbol": "fCLKin",+ "kind": "electrical",+ "unit": "GHz",+ "min": null,+ "typ": null,+ "max": 3.1,+ "conditions": "Functional up to 3.1 GHz",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Differential Input Voltage Swing",+ "symbol": "VID",+ "kind": "electrical",+ "unit": "V",+ "min": 0.15,+ "typ": null,+ "max": 1.3,+ "conditions": "",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Single-Ended Input Voltage Swing",+ "symbol": "VI_SE",+ "kind": "electrical",+ "unit": "Vpp",+ "min": 0.3,+ "typ": null,+ "max": 2,+ "conditions": "single-ended input; limited to 2 Vpp max for clock input frequency < 100 MHz (note 8)",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Mux Isolation, CLKin0 to CLKin1",+ "symbol": "ISOMUX",+ "kind": "electrical",+ "unit": "dBc",+ "min": null,+ "typ": null,+ "max": -84,+ "conditions": "fOFFSET > 50 kHz, PCLKinX = 0 dBm, fCLKin0 = 100 MHz",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "External Clock Frequency Range",+ "symbol": "FCLK",+ "kind": "electrical",+ "unit": "MHz",+ "min": null,+ "typ": null,+ "max": 250,+ "conditions": "OSCin driven single-ended, OSCout floating",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Crystal Frequency Range",+ "symbol": "FXTAL",+ "kind": "electrical",+ "unit": "MHz",+ "min": 10,+ "typ": null,+ "max": 40,+ "conditions": "Fundamental mode crystal, ESR ≤ 200 Ω (10 to 30 MHz), ESR ≤ 125 Ω (30 to 40 MHz)",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Maximum Output Frequency Full VOD Swing",+ "symbol": "fCLKout_FS",+ "kind": "electrical",+ "unit": "GHz",+ "min": null,+ "typ": 1,+ "max": 1.2,+ "conditions": "LVPECL, Vcco = 3.3 V ± 5%, RT = 160 Ω to GND, VOD ≥ 600 mV, RL = 100 Ω differential",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Maximum Output Frequency Reduced VOD Swing",+ "symbol": "fCLKout_RS",+ "kind": "electrical",+ "unit": "GHz",+ "min": null,+ "typ": 1.5,+ "max": 3.1,+ "conditions": "LVPECL, Vcco = 3.3 V ± 5%, RT = 160 Ω to GND, VOD ≥ 400 mV, RL = 100 Ω differential",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Additive RMS Jitter, Integration Bandwidth 10 kHz to 20 MHz",+ "symbol": "JitterADD",+ "kind": "electrical",+ "unit": "fs",+ "min": null,+ "typ": 77,+ "max": 98,+ "conditions": "LVPECL, Vcco = 3.3 V, CLKin: 100 MHz, Slew rate ≥ 3 V/ns",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Additive RMS Jitter, Integration Bandwidth 10 kHz to 20 MHz",+ "symbol": "JitterADD",+ "kind": "electrical",+ "unit": "fs",+ "min": null,+ "typ": 54,+ "max": 78,+ "conditions": "LVPECL, Vcco = 3.3 V, CLKin: 156.25 MHz, Slew rate ≥ 3 V/ns",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Duty Cycle",+ "symbol": "DUTY",+ "kind": "electrical",+ "unit": "%",+ "min": 45,+ "typ": null,+ "max": 55,+ "conditions": "LVPECL, 50% input clock duty cycle",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Output Voltage Swing",+ "symbol": "VOD",+ "kind": "electrical",+ "unit": "mV",+ "min": 600,+ "typ": 830,+ "max": 1000,+ "conditions": "LVPECL",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Output Rise Time",+ "symbol": "tR",+ "kind": "timing",+ "unit": "ps",+ "min": null,+ "typ": 175,+ "max": 300,+ "conditions": "LVPECL, 20% to 80%, RT = 160 Ω to GND, RL = 100 Ω differential, CL ≤ 5 pF",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Output Fall Time",+ "symbol": "tF",+ "kind": "timing",+ "unit": "ps",+ "min": null,+ "typ": 175,+ "max": 300,+ "conditions": "LVPECL, 80% to 20%, RT = 160 Ω to GND, RL = 100 Ω differential, CL ≤ 5 pF",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Propagation Delay CLKin-to-LVPECL",+ "symbol": "tPD_PECL",+ "kind": "timing",+ "unit": "ps",+ "min": 180,+ "typ": 360,+ "max": 540,+ "conditions": "RT = 160 Ω to GND, RL = 100 Ω differential, CL ≤ 5 pF",+ "source_page": 13,+ "source": "datasheet"+ },+ {+ "name": "Maximum Output Frequency Full VOD Swing",+ "symbol": "fCLKout_FS",+ "kind": "electrical",+ "unit": "GHz",+ "min": null,+ "typ": 1,+ "max": 1.6,+ "conditions": "LVDS, VOD ≥ 250 mV, RL = 100 Ω differential",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Maximum Output Frequency Reduced VOD Swing",+ "symbol": "fCLKout_RS",+ "kind": "electrical",+ "unit": "GHz",+ "min": null,+ "typ": 1.5,+ "max": 2.1,+ "conditions": "LVDS, VOD ≥ 200 mV, RL = 100 Ω differential",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Additive RMS Jitter, Integration Bandwidth 10 kHz to 20 MHz",+ "symbol": "JitterADD",+ "kind": "electrical",+ "unit": "fs",+ "min": null,+ "typ": 94,+ "max": 115,+ "conditions": "LVDS, RL = 100 Ω differential, CLKin: 100 MHz, Slew rate ≥ 3 V/ns",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Duty Cycle",+ "symbol": "DUTY",+ "kind": "electrical",+ "unit": "%",+ "min": 45,+ "typ": null,+ "max": 55,+ "conditions": "LVDS, 50% input clock duty cycle",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Output Voltage Swing",+ "symbol": "VOD",+ "kind": "electrical",+ "unit": "mV",+ "min": 250,+ "typ": 400,+ "max": 450,+ "conditions": "LVDS, TA = 25°C, DC Measurement, RL = 100 Ω differential",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Change in Magnitude of VOD for Complementary Output States",+ "symbol": "ΔVOD",+ "kind": "electrical",+ "unit": "mV",+ "min": -50,+ "typ": null,+ "max": 50,+ "conditions": "LVDS",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Output Offset Voltage",+ "symbol": "VOS",+ "kind": "electrical",+ "unit": "V",+ "min": 1.125,+ "typ": 1.25,+ "max": 1.375,+ "conditions": "LVDS",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Propagation Delay CLKin-to-LVDS",+ "symbol": "tPD_LVDS",+ "kind": "timing",+ "unit": "ps",+ "min": 200,+ "typ": 400,+ "max": 600,+ "conditions": "RL = 100 Ω differential, CL ≤ 5 pF",+ "source_page": 13,+ "source": "datasheet"+ },+ {+ "name": "Output Frequency Range",+ "symbol": "fCLKout",+ "kind": "electrical",+ "unit": "MHz",+ "min": null,+ "typ": null,+ "max": 400,+ "conditions": "HCSL, RL = 50 Ω to GND, CL ≤ 5 pF",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Duty Cycle",+ "symbol": "DUTY",+ "kind": "electrical",+ "unit": "%",+ "min": 45,+ "typ": null,+ "max": 55,+ "conditions": "HCSL, 50% input clock duty cycle",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Output High Voltage",+ "symbol": "VOH",+ "kind": "electrical",+ "unit": "mV",+ "min": 520,+ "typ": 810,+ "max": 920,+ "conditions": "HCSL, TA = 25°C, DC Measurement, RT = 50 Ω to GND",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Output Low Voltage",+ "symbol": "VOL",+ "kind": "electrical",+ "unit": "mV",+ "min": -150,+ "typ": 0.5,+ "max": 150,+ "conditions": "HCSL",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Absolute Crossing Voltage",+ "symbol": "VCROSS",+ "kind": "electrical",+ "unit": "mV",+ "min": 250,+ "typ": 350,+ "max": 460,+ "conditions": "HCSL, RL = 50 Ω to GND, CL ≤ 5 pF",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Output Rise Time",+ "symbol": "tR",+ "kind": "timing",+ "unit": "ps",+ "min": null,+ "typ": 300,+ "max": 500,+ "conditions": "HCSL, 20% to 80%, 250 MHz, RL = 50 Ω to GND, CL ≤ 5 pF",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Output Fall Time",+ "symbol": "tF",+ "kind": "timing",+ "unit": "ps",+ "min": null,+ "typ": 300,+ "max": 500,+ "conditions": "HCSL, 80% to 20%, RL = 50 Ω to GND, CL ≤ 5 pF",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Propagation Delay CLKin-to-HCSL",+ "symbol": "tPD_HCSL",+ "kind": "timing",+ "unit": "ps",+ "min": 295,+ "typ": 590,+ "max": 885,+ "conditions": "RT = 50 Ω to GND, CL ≤ 5 pF",+ "source_page": 13,+ "source": "datasheet"+ },+ {+ "name": "Output Skew LVPECL/LVDS/HCSL",+ "symbol": "tSK(O)",+ "kind": "timing",+ "unit": "ps",+ "min": null,+ "typ": 30,+ "max": 50,+ "conditions": "Skew between any two CLKouts with the same buffer type",+ "source_page": 13,+ "source": "datasheet"+ },+ {+ "name": "Maximum Output Frequency (LVCMOS)",+ "symbol": "fCLKout",+ "kind": "electrical",+ "unit": "MHz",+ "min": null,+ "typ": null,+ "max": 250,+ "conditions": "REFout LVCMOS, CL ≤ 5 pF",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Duty Cycle",+ "symbol": "DUTY",+ "kind": "electrical",+ "unit": "%",+ "min": 45,+ "typ": null,+ "max": 55,+ "conditions": "LVCMOS, 50% input clock duty cycle",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Output Low Voltage",+ "symbol": "VOL",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 0.1,+ "conditions": "LVCMOS, 1-mA load",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Output Enable Time",+ "symbol": "tEN",+ "kind": "timing",+ "unit": "cycles",+ "min": null,+ "typ": null,+ "max": 3,+ "conditions": "LVCMOS, CL ≤ 5 pF",+ "source_page": 12,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "lmk00304sq"+ ],+ "discovery_pitch": "LMK00304SQ (Texas Instruments) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+7−6@@ -4,7 +4,7 @@ "slug": "lmk00304sq", "title": "LMK00304SQ", "brief": "Texas Instruments Clock Buffers, Drivers, Distributors, WQFN-32-EP(5x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -25,7 +25,7 @@ "symbol": "lmk00304sq.kicad_sym", "footprint": "lmk00304sq.kicad_mod", "model_3d": "lmk00304sq-hero.glb",- "model_3d_plain": "lmk00304sq-etched.glb",+ "model_3d_plain": "lmk00304sq.glb", "model_3d_step": "lmk00304sq-etched.step", "model_3d_step_plain": "lmk00304sq.step", "lbr": "lmk00304sq.lbr"@@ -1075,9 +1075,10 @@ "viewers/footprint.html", "lmk00304sq-hero.glb", "lmk00304sq-hero.overlay.json",- "lmk00304sq-etched.glb"+ "lmk00304sq-etched.glb",+ "lmk00304sq-etched.step" ],- "visibility": {- "public": true- }+ "visibility": "public",+ "description": "Texas Instruments Clock Buffers, Drivers, Distributors, WQFN-32-EP(5x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "org": "adom" }