← Commit history

Publish 0.1.1

Ray ·f77ffe59b4 · ·parent a7de366
2 files changed +740−10
package.json+733−4
@@ -1,6 +1,6 @@ {   "slug": "lmk00304sq",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "Texas Instruments Clock Buffers, Drivers, Distributors, WQFN-32-EP(5x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",   "tags": [@@ -29,7 +29,8 @@     "viewers/footprint.html",     "lmk00304sq-hero.glb",     "lmk00304sq-hero.overlay.json",-    "lmk00304sq-etched.glb"+    "lmk00304sq-etched.glb",+    "lmk00304sq-etched.step"   ],   "component": {     "mpn": "LMK00304SQ",@@ -43,7 +44,7 @@       "symbol": "lmk00304sq.kicad_sym",       "footprint": "lmk00304sq.kicad_mod",       "model_3d": "lmk00304sq-hero.glb",-      "model_3d_plain": "lmk00304sq-etched.glb",+      "model_3d_plain": "lmk00304sq.glb",       "model_3d_step": "lmk00304sq-etched.step",       "model_3d_step_plain": "lmk00304sq.step",       "lbr": "lmk00304sq.lbr"@@ -336,5 +337,733 @@         "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"       }     ]-  }+  },+  "title": "LMK00304SQ",+  "brief": "Texas Instruments Clock Buffers, Drivers, Distributors, WQFN-32-EP(5x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "Texas Instruments",+      "Package": "WQFN-32-EP(5x5)",+      "Category": "Clock/Timing",+      "Pins": "33"+    },+    "appearance": {+      "contacts": {+        "quote": "(1) Any unused output pins should be left floating with minimum copper length (see note in Clock Outputs), or properly terminated if",+        "page": 5,+        "doc": "ds.pdf",+        "material": "copper"+      },+      "version": 1,+      "datasheet_sha256": "0e8ba3d15a7f8248b906d715bef07c70ffddbeb9e6de03d40b91b8a2fdc27666"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "0e8ba3d15a7f8248b906d715bef07c70ffddbeb9e6de03d40b91b8a2fdc27666",+      "rows": [+        {+          "name": "VCC, VCCO Supply Voltages",+          "symbol": "VCC, VCCO",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 3.6,+          "conditions": "over operating free-air temperature range",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Input Voltage",+          "symbol": "VIN",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "max VCC + 0.3",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Storage Temperature Range",+          "symbol": "TSTG",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Lead Temperature (solder 4 s)",+          "symbol": "TL",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "solder 4 s",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction Temperature",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Ambient Temperature Range",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": 25,+          "max": 85,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction Temperature",+          "symbol": "TJ",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Core Supply Voltage Range",+          "symbol": "VCC",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 3.15,+          "typ": 3.3,+          "max": 3.45,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-ambient thermal resistance",+          "symbol": "RθJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 38.1,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-case (top) thermal resistance",+          "symbol": "RθJC(top)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 7.2,+          "max": null,+          "conditions": "",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Core Supply Current, All Outputs Disabled",+          "symbol": "ICC_CORE",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 8.5,+          "max": 10.5,+          "conditions": "CLKinX selected",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Additive Core Supply Current, LVPECL Banks Enabled",+          "symbol": "ICC_PECL",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 38,+          "max": 48,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Additive Core Supply Current, LVDS Banks Enabled",+          "symbol": "ICC_LVDS",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 43,+          "max": 52,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Additive Core Supply Current, HCSL Banks Enabled",+          "symbol": "ICC_HCSL",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 50,+          "max": 58.5,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Additive Core Supply Current, LVCMOS Output Enabled",+          "symbol": "ICC_CMOS",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 3.5,+          "max": 5.5,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Additive Output Supply Current, LVPECL Banks Enabled",+          "symbol": "ICCO_PECL",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 135,+          "max": 163,+          "conditions": "Includes Output Bank Bias and Load Currents for both banks, RT = 50 Ω to Vcco – 2 V on all outputs",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Additive Output Supply Current, LVDS Banks Enabled",+          "symbol": "ICCO_LVDS",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 25,+          "max": 34.5,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Additive Output Supply Current, HCSL Banks Enabled",+          "symbol": "ICCO_HCSL",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 65,+          "max": 81.5,+          "conditions": "Includes Output Bank Bias and Load Currents for both banks, RT = 50 Ω on all outputs",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Additive Output Supply Current, LVCMOS Output Enabled",+          "symbol": "ICCO_CMOS",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 9,+          "max": 10,+          "conditions": "200 MHz, CL = 5 pF, Vcco = 3.3 V ± 5%",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "High-Level Input Voltage",+          "symbol": "VIH",+          "kind": "electrical",+          "unit": "V",+          "min": 1.6,+          "typ": null,+          "max": null,+          "conditions": "max Vcc",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Low-Level Input Voltage",+          "symbol": "VIL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.4,+          "conditions": "min GND",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Low-Level Input Current",+          "symbol": "IIL",+          "kind": "electrical",+          "unit": "µA",+          "min": -5,+          "typ": 0.1,+          "max": null,+          "conditions": "VIL = 0 V, Internal pulldown resistor",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Input Frequency Range",+          "symbol": "fCLKin",+          "kind": "electrical",+          "unit": "GHz",+          "min": null,+          "typ": null,+          "max": 3.1,+          "conditions": "Functional up to 3.1 GHz",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Differential Input Voltage Swing",+          "symbol": "VID",+          "kind": "electrical",+          "unit": "V",+          "min": 0.15,+          "typ": null,+          "max": 1.3,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Single-Ended Input Voltage Swing",+          "symbol": "VI_SE",+          "kind": "electrical",+          "unit": "Vpp",+          "min": 0.3,+          "typ": null,+          "max": 2,+          "conditions": "single-ended input; limited to 2 Vpp max for clock input frequency < 100 MHz (note 8)",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Mux Isolation, CLKin0 to CLKin1",+          "symbol": "ISOMUX",+          "kind": "electrical",+          "unit": "dBc",+          "min": null,+          "typ": null,+          "max": -84,+          "conditions": "fOFFSET > 50 kHz, PCLKinX = 0 dBm, fCLKin0 = 100 MHz",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "External Clock Frequency Range",+          "symbol": "FCLK",+          "kind": "electrical",+          "unit": "MHz",+          "min": null,+          "typ": null,+          "max": 250,+          "conditions": "OSCin driven single-ended, OSCout floating",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Crystal Frequency Range",+          "symbol": "FXTAL",+          "kind": "electrical",+          "unit": "MHz",+          "min": 10,+          "typ": null,+          "max": 40,+          "conditions": "Fundamental mode crystal, ESR ≤ 200 Ω (10 to 30 MHz), ESR ≤ 125 Ω (30 to 40 MHz)",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Maximum Output Frequency Full VOD Swing",+          "symbol": "fCLKout_FS",+          "kind": "electrical",+          "unit": "GHz",+          "min": null,+          "typ": 1,+          "max": 1.2,+          "conditions": "LVPECL, Vcco = 3.3 V ± 5%, RT = 160 Ω to GND, VOD ≥ 600 mV, RL = 100 Ω differential",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Maximum Output Frequency Reduced VOD Swing",+          "symbol": "fCLKout_RS",+          "kind": "electrical",+          "unit": "GHz",+          "min": null,+          "typ": 1.5,+          "max": 3.1,+          "conditions": "LVPECL, Vcco = 3.3 V ± 5%, RT = 160 Ω to GND, VOD ≥ 400 mV, RL = 100 Ω differential",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Additive RMS Jitter, Integration Bandwidth 10 kHz to 20 MHz",+          "symbol": "JitterADD",+          "kind": "electrical",+          "unit": "fs",+          "min": null,+          "typ": 77,+          "max": 98,+          "conditions": "LVPECL, Vcco = 3.3 V, CLKin: 100 MHz, Slew rate ≥ 3 V/ns",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Additive RMS Jitter, Integration Bandwidth 10 kHz to 20 MHz",+          "symbol": "JitterADD",+          "kind": "electrical",+          "unit": "fs",+          "min": null,+          "typ": 54,+          "max": 78,+          "conditions": "LVPECL, Vcco = 3.3 V, CLKin: 156.25 MHz, Slew rate ≥ 3 V/ns",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Duty Cycle",+          "symbol": "DUTY",+          "kind": "electrical",+          "unit": "%",+          "min": 45,+          "typ": null,+          "max": 55,+          "conditions": "LVPECL, 50% input clock duty cycle",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Output Voltage Swing",+          "symbol": "VOD",+          "kind": "electrical",+          "unit": "mV",+          "min": 600,+          "typ": 830,+          "max": 1000,+          "conditions": "LVPECL",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Output Rise Time",+          "symbol": "tR",+          "kind": "timing",+          "unit": "ps",+          "min": null,+          "typ": 175,+          "max": 300,+          "conditions": "LVPECL, 20% to 80%, RT = 160 Ω to GND, RL = 100 Ω differential, CL ≤ 5 pF",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Output Fall Time",+          "symbol": "tF",+          "kind": "timing",+          "unit": "ps",+          "min": null,+          "typ": 175,+          "max": 300,+          "conditions": "LVPECL, 80% to 20%, RT = 160 Ω to GND, RL = 100 Ω differential, CL ≤ 5 pF",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Propagation Delay CLKin-to-LVPECL",+          "symbol": "tPD_PECL",+          "kind": "timing",+          "unit": "ps",+          "min": 180,+          "typ": 360,+          "max": 540,+          "conditions": "RT = 160 Ω to GND, RL = 100 Ω differential, CL ≤ 5 pF",+          "source_page": 13,+          "source": "datasheet"+        },+        {+          "name": "Maximum Output Frequency Full VOD Swing",+          "symbol": "fCLKout_FS",+          "kind": "electrical",+          "unit": "GHz",+          "min": null,+          "typ": 1,+          "max": 1.6,+          "conditions": "LVDS, VOD ≥ 250 mV, RL = 100 Ω differential",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Maximum Output Frequency Reduced VOD Swing",+          "symbol": "fCLKout_RS",+          "kind": "electrical",+          "unit": "GHz",+          "min": null,+          "typ": 1.5,+          "max": 2.1,+          "conditions": "LVDS, VOD ≥ 200 mV, RL = 100 Ω differential",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Additive RMS Jitter, Integration Bandwidth 10 kHz to 20 MHz",+          "symbol": "JitterADD",+          "kind": "electrical",+          "unit": "fs",+          "min": null,+          "typ": 94,+          "max": 115,+          "conditions": "LVDS, RL = 100 Ω differential, CLKin: 100 MHz, Slew rate ≥ 3 V/ns",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Duty Cycle",+          "symbol": "DUTY",+          "kind": "electrical",+          "unit": "%",+          "min": 45,+          "typ": null,+          "max": 55,+          "conditions": "LVDS, 50% input clock duty cycle",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Output Voltage Swing",+          "symbol": "VOD",+          "kind": "electrical",+          "unit": "mV",+          "min": 250,+          "typ": 400,+          "max": 450,+          "conditions": "LVDS, TA = 25°C, DC Measurement, RL = 100 Ω differential",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Change in Magnitude of VOD for Complementary Output States",+          "symbol": "ΔVOD",+          "kind": "electrical",+          "unit": "mV",+          "min": -50,+          "typ": null,+          "max": 50,+          "conditions": "LVDS",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Output Offset Voltage",+          "symbol": "VOS",+          "kind": "electrical",+          "unit": "V",+          "min": 1.125,+          "typ": 1.25,+          "max": 1.375,+          "conditions": "LVDS",+          "source_page": 10,+          "source": "datasheet"+        },+        {+          "name": "Propagation Delay CLKin-to-LVDS",+          "symbol": "tPD_LVDS",+          "kind": "timing",+          "unit": "ps",+          "min": 200,+          "typ": 400,+          "max": 600,+          "conditions": "RL = 100 Ω differential, CL ≤ 5 pF",+          "source_page": 13,+          "source": "datasheet"+        },+        {+          "name": "Output Frequency Range",+          "symbol": "fCLKout",+          "kind": "electrical",+          "unit": "MHz",+          "min": null,+          "typ": null,+          "max": 400,+          "conditions": "HCSL, RL = 50 Ω to GND, CL ≤ 5 pF",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Duty Cycle",+          "symbol": "DUTY",+          "kind": "electrical",+          "unit": "%",+          "min": 45,+          "typ": null,+          "max": 55,+          "conditions": "HCSL, 50% input clock duty cycle",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Output High Voltage",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "mV",+          "min": 520,+          "typ": 810,+          "max": 920,+          "conditions": "HCSL, TA = 25°C, DC Measurement, RT = 50 Ω to GND",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Output Low Voltage",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "mV",+          "min": -150,+          "typ": 0.5,+          "max": 150,+          "conditions": "HCSL",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Absolute Crossing Voltage",+          "symbol": "VCROSS",+          "kind": "electrical",+          "unit": "mV",+          "min": 250,+          "typ": 350,+          "max": 460,+          "conditions": "HCSL, RL = 50 Ω to GND, CL ≤ 5 pF",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Output Rise Time",+          "symbol": "tR",+          "kind": "timing",+          "unit": "ps",+          "min": null,+          "typ": 300,+          "max": 500,+          "conditions": "HCSL, 20% to 80%, 250 MHz, RL = 50 Ω to GND, CL ≤ 5 pF",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Output Fall Time",+          "symbol": "tF",+          "kind": "timing",+          "unit": "ps",+          "min": null,+          "typ": 300,+          "max": 500,+          "conditions": "HCSL, 80% to 20%, RL = 50 Ω to GND, CL ≤ 5 pF",+          "source_page": 11,+          "source": "datasheet"+        },+        {+          "name": "Propagation Delay CLKin-to-HCSL",+          "symbol": "tPD_HCSL",+          "kind": "timing",+          "unit": "ps",+          "min": 295,+          "typ": 590,+          "max": 885,+          "conditions": "RT = 50 Ω to GND, CL ≤ 5 pF",+          "source_page": 13,+          "source": "datasheet"+        },+        {+          "name": "Output Skew LVPECL/LVDS/HCSL",+          "symbol": "tSK(O)",+          "kind": "timing",+          "unit": "ps",+          "min": null,+          "typ": 30,+          "max": 50,+          "conditions": "Skew between any two CLKouts with the same buffer type",+          "source_page": 13,+          "source": "datasheet"+        },+        {+          "name": "Maximum Output Frequency (LVCMOS)",+          "symbol": "fCLKout",+          "kind": "electrical",+          "unit": "MHz",+          "min": null,+          "typ": null,+          "max": 250,+          "conditions": "REFout LVCMOS, CL ≤ 5 pF",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "Duty Cycle",+          "symbol": "DUTY",+          "kind": "electrical",+          "unit": "%",+          "min": 45,+          "typ": null,+          "max": 55,+          "conditions": "LVCMOS, 50% input clock duty cycle",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "Output Low Voltage",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "LVCMOS, 1-mA load",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "Output Enable Time",+          "symbol": "tEN",+          "kind": "timing",+          "unit": "cycles",+          "min": null,+          "typ": null,+          "max": 3,+          "conditions": "LVCMOS, CL ≤ 5 pF",+          "source_page": 12,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "lmk00304sq"+  ],+  "discovery_pitch": "LMK00304SQ (Texas Instruments) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+7−6
@@ -4,7 +4,7 @@   "slug": "lmk00304sq",   "title": "LMK00304SQ",   "brief": "Texas Instruments Clock Buffers, Drivers, Distributors, WQFN-32-EP(5x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -25,7 +25,7 @@       "symbol": "lmk00304sq.kicad_sym",       "footprint": "lmk00304sq.kicad_mod",       "model_3d": "lmk00304sq-hero.glb",-      "model_3d_plain": "lmk00304sq-etched.glb",+      "model_3d_plain": "lmk00304sq.glb",       "model_3d_step": "lmk00304sq-etched.step",       "model_3d_step_plain": "lmk00304sq.step",       "lbr": "lmk00304sq.lbr"@@ -1075,9 +1075,10 @@     "viewers/footprint.html",     "lmk00304sq-hero.glb",     "lmk00304sq-hero.overlay.json",-    "lmk00304sq-etched.glb"+    "lmk00304sq-etched.glb",+    "lmk00304sq-etched.step"   ],-  "visibility": {-    "public": true-  }+  "visibility": "public",+  "description": "Texas Instruments Clock Buffers, Drivers, Distributors, WQFN-32-EP(5x5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "org": "adom" }\ No newline at end of file