lm5141rget: specified limits as data (metadata.characteristics, 60 rows from the datasheet)
2 files changed
+795−1
README.md+67@@ -43,6 +43,73 @@ LM5141RGET from Texas Instruments, in a VQFN-24(4x4). Pinout and pin description | Category | Power Management (PMIC) | | Pins | 25 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input voltage (absolute maximum) | VIN | -0.3 | | 70 | V | | 4 |+| SW to PGND | | -0.3 | | 70 | V | | 4 |+| SW to PGND (20 ns transient) | | -5 | | | V | 20 ns transient | 4 |+| HB to SW | | -0.3 | | 6.5 | V | | 4 |+| HB to SW (20 ns transient) | | -5 | | | V | 20 ns transient | 4 |+| HO, HOL to SW (max printed as HB + 0.3) | | -0.3 | | | V | | 4 |+| HO, HOL to SW (20 ns transient) | | -5 | | | V | 20 ns transient | 4 |+| LO, LOL to PGND (max printed as VCC + 0.3) | | -0.3 | | | V | | 4 |+| LO, LOL to PGND (20 ns transient) | | -1.5 | | | V | 20 ns transient | 4 |+| OSC, SS, COMP, RES, DEMB, RT, DITH (max printed as VDD + 0.3) | | -0.3 | | | V | | 4 |+| EN to PGND | | -0.3 | | 70 | V | | 4 |+| VCC, VCCX, VDD, PG, FB | | -0.3 | | 6.5 | V | | 4 |+| VOUT, CS | | -0.3 | | 15.5 | V | | 4 |+| PGND to AGND | | -0.3 | | 0.3 | V | | 4 |+| Operating junction temperature | TJ | -40 | | 150 | °C | | 4 |+| Storage temperature | Tstg | -65 | | 150 | °C | | 4 |+| Input voltage (recommended) | VIN | 3.8 | | 65 | V | | 5 |+| SW to PGND (recommended) | | -0.3 | | 65 | V | | 5 |+| HB to SW (recommended) | | -0.3 | 5 | 5.25 | V | | 5 |+| HO, HOL to SW (recommended, max printed as HB + 0.3) | | -0.3 | | | V | | 5 |+| LO, LOL to PGND (recommended) | | -0.3 | 5 | 5.25 | V | | 5 |+| FB, PG, OSC, SS, RES, DEMB, VCCX (recommended) | | -0.3 | | 5 | V | | 5 |+| EN to PGND (recommended) | | -0.3 | | 65 | V | | 5 |+| VCC, VDD (recommended) | | -0.3 | 5 | 5.25 | V | | 5 |+| VOUT, CS (recommended) | | 1.5 | 5 | 15 | V | | 5 |+| PGND to AGND (recommended) | | -0.3 | | 0.3 | V | | 5 |+| Operating junction temperature (recommended) | TJ | -40 | | 125 | °C | | 5 |+| Shutdown mode current | ISHUTDOWN | | 10 | 12.5 | µA | VIN = 8–18 V, EN = 0 V, VCCX = 0 V | 6 |+| Standby current | ISTANDBY | | 35 | 45 | µA | EN = 5 V, FB = VDD, VOUT in regulation, no-load, not switching, DEMB = GND. | 6 |+| VCC regulation voltage | VCC(REG) | 4.75 | 5 | 5.25 | V | VIN = 6–18 V, 0–75 mA, VCCX = 0 V | 6 |+| VCC under voltage threshold | VCC(UVLO) | 3.25 | 3.4 | 3.55 | V | VCC rising, VCCX = 0 V | 6 |+| VCC sourcing current limit | ICC(LIM) | | 85 | 125 | mA | VCCX = 0 V | 6 |+| Internal bias supply power (VDDA regulation) | VDDA(REG) | 4.75 | 5 | 5.25 | V | VCCX = 0 V | 6 |+| VDDA under voltage threshold | VDDA(UVLO) | 3.1 | 3.2 | 3.3 | V | VCC rising, VCCX = 0 V | 6 |+| VCCX on threshold | VCCX(ON) | 4.1 | 4.3 | 4.4 | V | VCC rising | 6 |+| Current limit threshold | V(CS) | 68 | 75 | 82 | mV | ILSET = VDDA, measure from CS to VOUT | 6 |+| Current sense amplifier gain | | 11.4 | 12 | 12.6 | V/V | | 6 |+| Output voltage regulation, 3.3 V option | | 3.273 | 3.3 | 3.327 | V | VIN = 3.8–42 V | 6 |+| Output voltage regulation, 5 V option | | 4.96 | 5 | 5.04 | V | VIN = 5.5–42 V | 6 |+| Regulated feedback voltage | | 1.193 | 1.2 | 1.207 | V | | 6 |+| Transconductance amplifier gain, feedback to COMP | Gm | 1010 | 1200 | | µS | | 7 |+| PG under voltage trip level | PG(UV) | 90 | 92 | 94 | % | Falling with respect to the regulation voltage | 7 |+| PG over voltage trip level | PG(OVP) | 108 | 110 | 112 | % | Rising with respect to the regulation voltage | 7 |+| DEMB input low frequency range | | 350 | | 550 | kHz | 440 kHz | 8 |+| DEMB input high frequency range | | 1800 | | 2600 | kHz | 2.2 MHz | 8 |+| Soft-start current | ISS | 16 | 22 | 28 | µA | | 8 |+| HO off to LO on dead time | tdly1 | 20 | | 40 | ns | | 7 |+| LO off to HO on dead time | tdly2 | 20 | | 38 | ns | | 7 |+| Oscillator frequency 2.2 MHz | | 2100 | 2200 | 2300 | kHz | OSC = VDDA, VIN = 8–18 V | 8 |+| Oscillator frequency 440 kHz | | 420 | 440 | 460 | kHz | OSC = GND, VIN = 8–18 V | 8 |+| RT adjustment range, 2.2 MHz minimum | | 1710 | 1800 | 1890 | kHz | OSC = VDD, RTMIN = 61.9 kΩ | 8 |+| RT adjustment range, 2.2 MHz typical | | 2100 | 2200 | 2300 | kHz | OSC = VDD, RTTYP = 49.9 kΩ | 8 |+| RT adjustment range, 2.2 MHz maximum | | 2405 | 2530 | 2655 | kHz | OSC = VDD, RTMAX = 43.2 kΩ | 8 |+| RT adjustment range, 440 kHz minimum | | 285 | 300 | 315 | kHz | OSC = GND, RTMIN = 73.2 kΩ | 8 |+| RT adjustment range, 440 kHz typical | | 420 | 440 | 460 | kHz | OSC = GND, RTTYP = 49.9 kΩ | 8 |+| RT adjustment range, 440 kHz maximum | | 475 | 500 | 525 | kHz | OSC = GND, RTMAX = 44.2 kΩ | 8 |+| Minimum on-time | ton | 45 | | 66 | ns | | 8 |+| Junction-to-ambient thermal resistance | RθJA | | 34.1 | | °C/W | | 5 |+| Junction-to-board thermal resistance | RθJB | | 12.1 | | °C/W | | 5 |+| Junction-to-case (bottom) thermal resistance | RθJC(bot) | | 2.9 | | °C/W | | 5 |+ ## CAD (KiCad official) - Symbol: `LM5141RGET`
page.json+728−1@@ -282,6 +282,733 @@ "Package": "VQFN-24(4x4)", "Category": "Power Management (PMIC)", "Pins": "25"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "7e612d227f860930",+ "rows": [+ {+ "name": "Input voltage (absolute maximum)",+ "symbol": "VIN",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 70,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "SW to PGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 70,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "SW to PGND (20 ns transient)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -5,+ "typ": null,+ "max": null,+ "conditions": "20 ns transient",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "HB to SW",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "HB to SW (20 ns transient)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -5,+ "typ": null,+ "max": null,+ "conditions": "20 ns transient",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "HO, HOL to SW (max printed as HB + 0.3)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "HO, HOL to SW (20 ns transient)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -5,+ "typ": null,+ "max": null,+ "conditions": "20 ns transient",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "LO, LOL to PGND (max printed as VCC + 0.3)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "LO, LOL to PGND (20 ns transient)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -1.5,+ "typ": null,+ "max": null,+ "conditions": "20 ns transient",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "OSC, SS, COMP, RES, DEMB, RT, DITH (max printed as VDD + 0.3)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "EN to PGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 70,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VCC, VCCX, VDD, PG, FB",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "VOUT, CS",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 15.5,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "PGND to AGND",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 0.3,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "Tstg",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Input voltage (recommended)",+ "symbol": "VIN",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 3.8,+ "typ": null,+ "max": 65,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "SW to PGND (recommended)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 65,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "HB to SW (recommended)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.3,+ "typ": 5,+ "max": 5.25,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "HO, HOL to SW (recommended, max printed as HB + 0.3)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "LO, LOL to PGND (recommended)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.3,+ "typ": 5,+ "max": 5.25,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "FB, PG, OSC, SS, RES, DEMB, VCCX (recommended)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 5,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "EN to PGND (recommended)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 65,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "VCC, VDD (recommended)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.3,+ "typ": 5,+ "max": 5.25,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "VOUT, CS (recommended)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 1.5,+ "typ": 5,+ "max": 15,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "PGND to AGND (recommended)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 0.3,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature (recommended)",+ "symbol": "TJ",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Shutdown mode current",+ "symbol": "ISHUTDOWN",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 10,+ "max": 12.5,+ "conditions": "VIN = 8–18 V, EN = 0 V, VCCX = 0 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Standby current",+ "symbol": "ISTANDBY",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 35,+ "max": 45,+ "conditions": "EN = 5 V, FB = VDD, VOUT in regulation, no-load, not switching, DEMB = GND.",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCC regulation voltage",+ "symbol": "VCC(REG)",+ "kind": "electrical",+ "unit": "V",+ "min": 4.75,+ "typ": 5,+ "max": 5.25,+ "conditions": "VIN = 6–18 V, 0–75 mA, VCCX = 0 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCC under voltage threshold",+ "symbol": "VCC(UVLO)",+ "kind": "electrical",+ "unit": "V",+ "min": 3.25,+ "typ": 3.4,+ "max": 3.55,+ "conditions": "VCC rising, VCCX = 0 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCC sourcing current limit",+ "symbol": "ICC(LIM)",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 85,+ "max": 125,+ "conditions": "VCCX = 0 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Internal bias supply power (VDDA regulation)",+ "symbol": "VDDA(REG)",+ "kind": "electrical",+ "unit": "V",+ "min": 4.75,+ "typ": 5,+ "max": 5.25,+ "conditions": "VCCX = 0 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VDDA under voltage threshold",+ "symbol": "VDDA(UVLO)",+ "kind": "electrical",+ "unit": "V",+ "min": 3.1,+ "typ": 3.2,+ "max": 3.3,+ "conditions": "VCC rising, VCCX = 0 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCCX on threshold",+ "symbol": "VCCX(ON)",+ "kind": "electrical",+ "unit": "V",+ "min": 4.1,+ "typ": 4.3,+ "max": 4.4,+ "conditions": "VCC rising",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Current limit threshold",+ "symbol": "V(CS)",+ "kind": "electrical",+ "unit": "mV",+ "min": 68,+ "typ": 75,+ "max": 82,+ "conditions": "ILSET = VDDA, measure from CS to VOUT",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Current sense amplifier gain",+ "symbol": "",+ "kind": "electrical",+ "unit": "V/V",+ "min": 11.4,+ "typ": 12,+ "max": 12.6,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Output voltage regulation, 3.3 V option",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 3.273,+ "typ": 3.3,+ "max": 3.327,+ "conditions": "VIN = 3.8–42 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Output voltage regulation, 5 V option",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 4.96,+ "typ": 5,+ "max": 5.04,+ "conditions": "VIN = 5.5–42 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Regulated feedback voltage",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 1.193,+ "typ": 1.2,+ "max": 1.207,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Transconductance amplifier gain, feedback to COMP",+ "symbol": "Gm",+ "kind": "electrical",+ "unit": "µS",+ "min": 1010,+ "typ": 1200,+ "max": null,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "PG under voltage trip level",+ "symbol": "PG(UV)",+ "kind": "electrical",+ "unit": "%",+ "min": 90,+ "typ": 92,+ "max": 94,+ "conditions": "Falling with respect to the regulation voltage",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "PG over voltage trip level",+ "symbol": "PG(OVP)",+ "kind": "electrical",+ "unit": "%",+ "min": 108,+ "typ": 110,+ "max": 112,+ "conditions": "Rising with respect to the regulation voltage",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "DEMB input low frequency range",+ "symbol": "",+ "kind": "electrical",+ "unit": "kHz",+ "min": 350,+ "typ": null,+ "max": 550,+ "conditions": "440 kHz",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "DEMB input high frequency range",+ "symbol": "",+ "kind": "electrical",+ "unit": "kHz",+ "min": 1800,+ "typ": null,+ "max": 2600,+ "conditions": "2.2 MHz",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Soft-start current",+ "symbol": "ISS",+ "kind": "electrical",+ "unit": "µA",+ "min": 16,+ "typ": 22,+ "max": 28,+ "conditions": "",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "HO off to LO on dead time",+ "symbol": "tdly1",+ "kind": "timing",+ "unit": "ns",+ "min": 20,+ "typ": null,+ "max": 40,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "LO off to HO on dead time",+ "symbol": "tdly2",+ "kind": "timing",+ "unit": "ns",+ "min": 20,+ "typ": null,+ "max": 38,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Oscillator frequency 2.2 MHz",+ "symbol": "",+ "kind": "electrical",+ "unit": "kHz",+ "min": 2100,+ "typ": 2200,+ "max": 2300,+ "conditions": "OSC = VDDA, VIN = 8–18 V",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Oscillator frequency 440 kHz",+ "symbol": "",+ "kind": "electrical",+ "unit": "kHz",+ "min": 420,+ "typ": 440,+ "max": 460,+ "conditions": "OSC = GND, VIN = 8–18 V",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "RT adjustment range, 2.2 MHz minimum",+ "symbol": "",+ "kind": "electrical",+ "unit": "kHz",+ "min": 1710,+ "typ": 1800,+ "max": 1890,+ "conditions": "OSC = VDD, RTMIN = 61.9 kΩ",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "RT adjustment range, 2.2 MHz typical",+ "symbol": "",+ "kind": "electrical",+ "unit": "kHz",+ "min": 2100,+ "typ": 2200,+ "max": 2300,+ "conditions": "OSC = VDD, RTTYP = 49.9 kΩ",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "RT adjustment range, 2.2 MHz maximum",+ "symbol": "",+ "kind": "electrical",+ "unit": "kHz",+ "min": 2405,+ "typ": 2530,+ "max": 2655,+ "conditions": "OSC = VDD, RTMAX = 43.2 kΩ",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "RT adjustment range, 440 kHz minimum",+ "symbol": "",+ "kind": "electrical",+ "unit": "kHz",+ "min": 285,+ "typ": 300,+ "max": 315,+ "conditions": "OSC = GND, RTMIN = 73.2 kΩ",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "RT adjustment range, 440 kHz typical",+ "symbol": "",+ "kind": "electrical",+ "unit": "kHz",+ "min": 420,+ "typ": 440,+ "max": 460,+ "conditions": "OSC = GND, RTTYP = 49.9 kΩ",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "RT adjustment range, 440 kHz maximum",+ "symbol": "",+ "kind": "electrical",+ "unit": "kHz",+ "min": 475,+ "typ": 500,+ "max": 525,+ "conditions": "OSC = GND, RTMAX = 44.2 kΩ",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Minimum on-time",+ "symbol": "ton",+ "kind": "timing",+ "unit": "ns",+ "min": 45,+ "typ": null,+ "max": 66,+ "conditions": "",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-ambient thermal resistance",+ "symbol": "RθJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 34.1,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-board thermal resistance",+ "symbol": "RθJB",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 12.1,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-case (bottom) thermal resistance",+ "symbol": "RθJC(bot)",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 2.9,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -323,4 +1050,4 @@ "visibility": { "public": true }-}+}