← Commit history
lm4040d50ilp: specified limits as data (metadata.characteristics, 17 rows from the datasheet)
2 files changed
+236−1
README.md+24@@ -21,6 +21,30 @@ LM4040D50ILP from Texas Instruments, in a TO-92-3. Pinout and pin descriptions e | Category | Power Management (PMIC) | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Reverse breakdown voltage tolerance (25°C, IZ = 100µA) | ΔVZ | -50 | | 50 | mV | IZ = 100µA, 25°C | 18 |+| Reverse breakdown voltage tolerance (full range) | ΔVZ | -99 | | 99 | mV | IZ = 100µA, full range TA = -40°C to 85°C | 18 |+| Minimum cathode current | IZ,min | | 65 | 89 | µA | 25°C | 18 |+| Minimum cathode current (full range) | IZ,min | | | 95 | µA | full range TA = -40°C to 85°C | 18 |+| Average temperature coefficient of VZ | αVZ | -30 | | 30 | ppm/°C | IZ = 10mA, 25°C | 18 |+| Average temperature coefficient of VZ | αVZ | -20 | | 20 | ppm/°C | IZ = 1mA, 25°C | 18 |+| Average temperature coefficient of VZ (full range) | αVZ | -150 | | 150 | ppm/°C | full range TA = -40°C to 85°C | 18 |+| Change of VZ with cathode current | VZ | | 0.5 | 1.3 | mV | IZ,min < IZ < 1mA, 25°C | 18 |+| Change of VZ with cathode current (full range) | VZ | | | 1.8 | mV | IZ,min < IZ < 1mA, full range TA = -40°C to 85°C | 18 |+| Change of VZ with cathode current | VZ | | 3.5 | 10 | mV | 1mA < IZ < 15mA, 25°C | 18 |+| Change of VZ with cathode current (full range) | VZ | | | 15 | mV | 1mA < IZ < 15mA, full range TA = -40°C to 85°C | 18 |+| Reverse dynamic impedance | ZZ | | 0.5 | 1.5 | Ω | IZ = 1mA, f = 120Hz, IAC = 0.1IZ, 25°C | 18 |+| Continuous cathode current | IZ | -10 | | 25 | mA | | 5 |+| Operating junction temperature | TJ | | | 150 | °C | | 5 |+| Storage temperature range | Tstg | -65 | | 150 | °C | | 5 |+| Cathode current | IZ | | | 15 | mA | | 5 |+| Natural-air ambient temperature (LM4040xxxI) | TA | -40 | | 85 | °C | LM4040xxxI | 5 |+ ## CAD (KiCad official) - Symbol: `LM4040D50ILP`
page.json+212−1@@ -150,6 +150,217 @@ "Package": "TO-92-3", "Category": "Power Management (PMIC)", "Pins": "3"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "68faec55d71e5cd5",+ "rows": [+ {+ "name": "Reverse breakdown voltage tolerance (25°C, IZ = 100µA)",+ "symbol": "ΔVZ",+ "kind": "tolerance",+ "unit": "mV",+ "min": -50,+ "typ": null,+ "max": 50,+ "conditions": "IZ = 100µA, 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Reverse breakdown voltage tolerance (full range)",+ "symbol": "ΔVZ",+ "kind": "tolerance",+ "unit": "mV",+ "min": -99,+ "typ": null,+ "max": 99,+ "conditions": "IZ = 100µA, full range TA = -40°C to 85°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Minimum cathode current",+ "symbol": "IZ,min",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 65,+ "max": 89,+ "conditions": "25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Minimum cathode current (full range)",+ "symbol": "IZ,min",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": 95,+ "conditions": "full range TA = -40°C to 85°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Average temperature coefficient of VZ",+ "symbol": "αVZ",+ "kind": "temperature_coefficient",+ "unit": "ppm/°C",+ "min": -30,+ "typ": null,+ "max": 30,+ "conditions": "IZ = 10mA, 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Average temperature coefficient of VZ",+ "symbol": "αVZ",+ "kind": "temperature_coefficient",+ "unit": "ppm/°C",+ "min": -20,+ "typ": null,+ "max": 20,+ "conditions": "IZ = 1mA, 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Average temperature coefficient of VZ (full range)",+ "symbol": "αVZ",+ "kind": "temperature_coefficient",+ "unit": "ppm/°C",+ "min": -150,+ "typ": null,+ "max": 150,+ "conditions": "full range TA = -40°C to 85°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Change of VZ with cathode current",+ "symbol": "VZ",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 0.5,+ "max": 1.3,+ "conditions": "IZ,min < IZ < 1mA, 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Change of VZ with cathode current (full range)",+ "symbol": "VZ",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 1.8,+ "conditions": "IZ,min < IZ < 1mA, full range TA = -40°C to 85°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Change of VZ with cathode current",+ "symbol": "VZ",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 3.5,+ "max": 10,+ "conditions": "1mA < IZ < 15mA, 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Change of VZ with cathode current (full range)",+ "symbol": "VZ",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 15,+ "conditions": "1mA < IZ < 15mA, full range TA = -40°C to 85°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Reverse dynamic impedance",+ "symbol": "ZZ",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 0.5,+ "max": 1.5,+ "conditions": "IZ = 1mA, f = 120Hz, IAC = 0.1IZ, 25°C",+ "source_page": 18,+ "source": "datasheet"+ },+ {+ "name": "Continuous cathode current",+ "symbol": "IZ",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -10,+ "typ": null,+ "max": 25,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature range",+ "symbol": "Tstg",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Cathode current",+ "symbol": "IZ",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 15,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Natural-air ambient temperature (LM4040xxxI)",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "LM4040xxxI",+ "source_page": 5,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -191,4 +402,4 @@ "visibility": { "public": true }-}+}