← Commit history

lm4040cim3-5-0-t: specified limits as data (metadata.characteristics, 18 rows from the datasheet)

Ray ·2ce7eacdf6 · ·parent bcc2ad9
2 files changed +248
README.md+25
@@ -31,6 +31,31 @@ Same part, different packaging or reel option. - `LM4040CIM3-5.0+TCIX3-5.0+T` - `LM4040CIM3-5.0+TCEX3-5.0+T` +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Reverse Breakdown Voltage (LM4040C, 5.000V) | VR | 4.975 | 5 | 5.025 | V | TA = +25°C | 8 |+| Reverse Breakdown Voltage Tolerance (LM4040C, 5.000V) | VR | -58 | 25 | 58 | mV |  | 8 |+| Minimum Operating Current (LM4040A/B/C) | IRMIN | 54 |  | 80 | µA |  | 8 |+| Average Reverse Voltage Temperature Coefficient (LM4040A/B/C) | ∆VR/∆T | -100 | 20 | 100 | ppm/°C | IR = 1mA | 8 |+| Reverse Breakdown Voltage Change with Operating Current Change (LM4040A/B/C) |  |  | 0.5 | 1.4 | mV | IRMIN ≤ IR ≤ 1mA | 8 |+| Reverse Breakdown Voltage Change with Operating Current Change (LM4040A/B/C) |  |  | 3.5 | 12 | mV | 1mA ≤ IR ≤ 15mA | 8 |+| Reverse Dynamic Impedance (LM4040A/B/C) | ZR |  | 0.5 | 1.1 | Ω | IR = 1mA, f = 120Hz, IAC = 0.1IR | 8 |+| Reverse Current (cathode to anode) |  |  |  | 20 | mA |  | 2 |+| Forward Current (anode to cathode) |  |  |  | 10 | mA |  | 2 |+| Operating Temperature Range (LM4040_I_ _ _) | TA | -40 |  | 85 | °C | LM4040_I_ _ _ | 2 |+| Storage Temperature Range | TSTG | -65 |  | 150 | °C |  | 2 |+| Junction Temperature | TJ |  |  | 150 | °C |  | 2 |+| Lead Temperature (soldering) |  |  |  | 300 | °C | soldering, 10s | 2 |+| Soldering Temperature (reflow) |  |  |  | 260 | °C |  | 2 |+| Thermal Resistance Junction to Ambient (3 SOT23) | θJA |  | 336 |  | °C/W | Four-Layer Board, JEDEC JESD51-7 | 2 |+| Thermal Resistance Junction to Case (3 SOT23) | θJC |  | 110.1 |  | °C/W | Four-Layer Board, JEDEC JESD51-7 | 2 |+| Shunt Current (minimum, at all times) | ISHUNT | 60 |  |  | µA | Application guidance: maintain at all times | 13 |+| Shunt Current (maximum for proper regulation) | ISHUNT |  |  | 15 | mA | Application guidance: VS at maximum and ILOAD at minimum | 13 |+ ## CAD (KiCad official)  - Symbol: `LM4040CIM3-5.0+T`
page.json+223
@@ -116,6 +116,229 @@       "Package": "SOT-23-3",       "Category": "Power Management (PMIC)",       "Pins": "3"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "cb26444d98d751a0",+      "rows": [+        {+          "name": "Reverse Breakdown Voltage (LM4040C, 5.000V)",+          "symbol": "VR",+          "kind": "electrical",+          "unit": "V",+          "min": 4.975,+          "typ": 5,+          "max": 5.025,+          "conditions": "TA = +25°C",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Reverse Breakdown Voltage Tolerance (LM4040C, 5.000V)",+          "symbol": "VR",+          "kind": "tolerance",+          "unit": "mV",+          "min": -58,+          "typ": 25,+          "max": 58,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Minimum Operating Current (LM4040A/B/C)",+          "symbol": "IRMIN",+          "kind": "electrical",+          "unit": "µA",+          "min": 54,+          "typ": null,+          "max": 80,+          "conditions": "",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Average Reverse Voltage Temperature Coefficient (LM4040A/B/C)",+          "symbol": "∆VR/∆T",+          "kind": "temperature_coefficient",+          "unit": "ppm/°C",+          "min": -100,+          "typ": 20,+          "max": 100,+          "conditions": "IR = 1mA",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Reverse Breakdown Voltage Change with Operating Current Change (LM4040A/B/C)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": 0.5,+          "max": 1.4,+          "conditions": "IRMIN ≤ IR ≤ 1mA",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Reverse Breakdown Voltage Change with Operating Current Change (LM4040A/B/C)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": 3.5,+          "max": 12,+          "conditions": "1mA ≤ IR ≤ 15mA",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Reverse Dynamic Impedance (LM4040A/B/C)",+          "symbol": "ZR",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": 0.5,+          "max": 1.1,+          "conditions": "IR = 1mA, f = 120Hz, IAC = 0.1IR",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Reverse Current (cathode to anode)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Forward Current (anode to cathode)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Operating Temperature Range (LM4040_I_ _ _)",+          "symbol": "TA",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "LM4040_I_ _ _",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage Temperature Range",+          "symbol": "TSTG",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Junction Temperature",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Lead Temperature (soldering)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 300,+          "conditions": "soldering, 10s",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Soldering Temperature (reflow)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Thermal Resistance Junction to Ambient (3 SOT23)",+          "symbol": "θJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 336,+          "max": null,+          "conditions": "Four-Layer Board, JEDEC JESD51-7",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Thermal Resistance Junction to Case (3 SOT23)",+          "symbol": "θJC",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 110.1,+          "max": null,+          "conditions": "Four-Layer Board, JEDEC JESD51-7",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Shunt Current (minimum, at all times)",+          "symbol": "ISHUNT",+          "kind": "recommended_operating",+          "unit": "µA",+          "min": 60,+          "typ": null,+          "max": null,+          "conditions": "Application guidance: maintain at all times",+          "source_page": 13,+          "source": "datasheet"+        },+        {+          "name": "Shunt Current (maximum for proper regulation)",+          "symbol": "ISHUNT",+          "kind": "recommended_operating",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 15,+          "conditions": "Application guidance: VS at maximum and ILOAD at minimum",+          "source_page": 13,+          "source": "datasheet"+        }+      ]     }   },   "variants": [