← Commit history
lm4040b30idckr: specified limits as data (metadata.characteristics, 21 rows from the datasheet)
2 files changed
+288−1
README.md+28@@ -23,6 +23,34 @@ LM4040B30IDCKR from Texas Instruments, in a SC-70-5. Pinout and pin descriptions | Category | Power Management (PMIC) | | Pins | 5 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Reverse breakdown voltage change, tolerance (25°C), 3V B-grade, IZ=100μA | ΔVZ | -6 | | 6 | mV | IZ = 100μA, 25°C | 12 |+| Reverse breakdown voltage tolerance over full temperature range, B-grade | ΔVZ | -26 | | 26 | mV | IZ = 100μA, full range TA = -40°C to 85°C | 12 |+| Minimum cathode current, 25°C | IZ,min | | 47 | 77 | μA | 25°C | 12 |+| Minimum cathode current, full range | IZ,min | | | 82 | μA | full range TA = -40°C to 85°C | 12 |+| Average temperature coefficient of reverse breakdown voltage | αVZ | -20 | | 20 | ppm/°C | IZ = 10mA, 25°C | 12 |+| Average temperature coefficient of reverse breakdown voltage | αVZ | -15 | | 15 | ppm/°C | IZ = 1mA, 25°C | 12 |+| Average temperature coefficient of reverse breakdown voltage | αVZ | -100 | | 100 | ppm/°C | IZ = 1mA, full range TA = -40°C to 85°C | 12 |+| Reverse breakdown voltage change with cathode current | VZ | | 0.6 | 0.8 | mV | IZ,min < IZ < 1mA, 25°C | 12 |+| Reverse breakdown voltage change with cathode current, full range | VZ | | | 1.1 | mV | IZ,min < IZ < 1mA, full range TA = -40°C to 85°C | 12 |+| Reverse breakdown voltage change with cathode current | VZ | | 2.7 | 6 | mV | 1mA < IZ < 15mA, 25°C | 12 |+| Reverse breakdown voltage change with cathode current, full range | VZ | | | 9 | mV | 1mA < IZ < 15mA, full range TA = -40°C to 85°C | 12 |+| Reverse dynamic impedance | ZZ | | 0.4 | 0.9 | Ω | IZ = 1mA, f = 120Hz, IAC = 0.1IZ, 25°C | 12 |+| Recommended cathode current | IZ | | | 15 | mA | cathode current (see electrical table) | 5 |+| Recommended ambient temperature, LM4040xxxI | TA | -40 | | 85 | °C | LM4040xxxI (industrial grade) | 5 |+| Continuous cathode current, absolute maximum | IZ | -10 | | 25 | mA | continuous cathode current, natural ventilation | 5 |+| Operating virtual junction temperature, absolute maximum | TJ | | | 150 | °C | | 5 |+| Storage temperature range | Tstg | -65 | | 150 | °C | | 5 |+| Wideband noise voltage | eN | | 35 | | μVRMS | IZ = 100μA, 10Hz ≤ f ≤ 10kHz, 25°C | 12 |+| Long-term stability of reverse breakdown voltage | | | 120 | | ppm | t = 1000 h, TA = 25°C ± 0.1°C, IZ = 100μA | 12 |+| Thermal hysteresis | VHYST | | 0.08 | | % | ΔTA = -40°C to 125°C | 12 |+| Junction-to-ambient thermal resistance, DCK (5-pin) package | RθJA | | 252 | | °C/W | DCK 5-pin package | 5 |+ ## CAD (KiCad official) - Symbol: `LM4040B30IDCKR`
page.json+260−1@@ -162,6 +162,265 @@ "Package": "SC-70-5", "Category": "Power Management (PMIC)", "Pins": "5"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "68faec55d71e5cd5",+ "rows": [+ {+ "name": "Reverse breakdown voltage change, tolerance (25°C), 3V B-grade, IZ=100μA",+ "symbol": "ΔVZ",+ "kind": "tolerance",+ "unit": "mV",+ "min": -6,+ "typ": null,+ "max": 6,+ "conditions": "IZ = 100μA, 25°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Reverse breakdown voltage tolerance over full temperature range, B-grade",+ "symbol": "ΔVZ",+ "kind": "tolerance",+ "unit": "mV",+ "min": -26,+ "typ": null,+ "max": 26,+ "conditions": "IZ = 100μA, full range TA = -40°C to 85°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Minimum cathode current, 25°C",+ "symbol": "IZ,min",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": 47,+ "max": 77,+ "conditions": "25°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Minimum cathode current, full range",+ "symbol": "IZ,min",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": null,+ "max": 82,+ "conditions": "full range TA = -40°C to 85°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Average temperature coefficient of reverse breakdown voltage",+ "symbol": "αVZ",+ "kind": "temperature_coefficient",+ "unit": "ppm/°C",+ "min": -20,+ "typ": null,+ "max": 20,+ "conditions": "IZ = 10mA, 25°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Average temperature coefficient of reverse breakdown voltage",+ "symbol": "αVZ",+ "kind": "temperature_coefficient",+ "unit": "ppm/°C",+ "min": -15,+ "typ": null,+ "max": 15,+ "conditions": "IZ = 1mA, 25°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Average temperature coefficient of reverse breakdown voltage",+ "symbol": "αVZ",+ "kind": "temperature_coefficient",+ "unit": "ppm/°C",+ "min": -100,+ "typ": null,+ "max": 100,+ "conditions": "IZ = 1mA, full range TA = -40°C to 85°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Reverse breakdown voltage change with cathode current",+ "symbol": "VZ",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 0.6,+ "max": 0.8,+ "conditions": "IZ,min < IZ < 1mA, 25°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Reverse breakdown voltage change with cathode current, full range",+ "symbol": "VZ",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 1.1,+ "conditions": "IZ,min < IZ < 1mA, full range TA = -40°C to 85°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Reverse breakdown voltage change with cathode current",+ "symbol": "VZ",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 2.7,+ "max": 6,+ "conditions": "1mA < IZ < 15mA, 25°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Reverse breakdown voltage change with cathode current, full range",+ "symbol": "VZ",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 9,+ "conditions": "1mA < IZ < 15mA, full range TA = -40°C to 85°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Reverse dynamic impedance",+ "symbol": "ZZ",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 0.4,+ "max": 0.9,+ "conditions": "IZ = 1mA, f = 120Hz, IAC = 0.1IZ, 25°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Recommended cathode current",+ "symbol": "IZ",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 15,+ "conditions": "cathode current (see electrical table)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Recommended ambient temperature, LM4040xxxI",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "LM4040xxxI (industrial grade)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Continuous cathode current, absolute maximum",+ "symbol": "IZ",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -10,+ "typ": null,+ "max": 25,+ "conditions": "continuous cathode current, natural ventilation",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Operating virtual junction temperature, absolute maximum",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature range",+ "symbol": "Tstg",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Wideband noise voltage",+ "symbol": "eN",+ "kind": "electrical",+ "unit": "μVRMS",+ "min": null,+ "typ": 35,+ "max": null,+ "conditions": "IZ = 100μA, 10Hz ≤ f ≤ 10kHz, 25°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Long-term stability of reverse breakdown voltage",+ "symbol": "",+ "kind": "electrical",+ "unit": "ppm",+ "min": null,+ "typ": 120,+ "max": null,+ "conditions": "t = 1000 h, TA = 25°C ± 0.1°C, IZ = 100μA",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Thermal hysteresis",+ "symbol": "VHYST",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": 0.08,+ "max": null,+ "conditions": "ΔTA = -40°C to 125°C",+ "source_page": 12,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-ambient thermal resistance, DCK (5-pin) package",+ "symbol": "RθJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 252,+ "max": null,+ "conditions": "DCK 5-pin package",+ "source_page": 5,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -203,4 +462,4 @@ "visibility": { "public": true }-}+}