← Commit history
page.json+11−8@@ -32,13 +32,13 @@ "number": "1", "name": "VCC", "type": "power_in",- "description": "Input supply. Operating range 2.7 V to 5.5 V (absolute max 6.0 V). Typical quiescent current 80 \u00b5A."+ "description": "Input supply. Operating range 2.7 V to 5.5 V (absolute max 6.0 V). Typical quiescent current 80 µA." }, { "number": "2", "name": "EN", "type": "input",- "description": "Precision enable input. Typical threshold 1.22 V (min 1.0 V, max 1.5 V). Internal 7 \u00b5A pull-up current when VEN = 0 V. Asserting EN starts the power-up sequence."+ "description": "Precision enable input. Typical threshold 1.22 V (min 1.0 V, max 1.5 V). Internal 7 µA pull-up current when VEN = 0 V. Asserting EN starts the power-up sequence." }, { "number": "3",@@ -50,31 +50,31 @@ "number": "4", "name": "INV", "type": "input",- "description": "Output logic invert. Logic level input that inverts the FLAG output polarity. VIH \u2265 90% VCC, VIL \u2264 10% VCC. Must be tied to a valid logic high or low; not allowed to float."+ "description": "Output logic invert. Logic level input that inverts the FLAG output polarity. VIH ≥ 90% VCC, VIL ≤ 10% VCC. Must be tied to a valid logic high or low; not allowed to float." }, { "number": "5", "name": "TADJ", "type": "passive",- "description": "Timer adjust. Connect an external timing capacitor from TADJ to GND to set the clock period (~120 \u00b5s/nF; e.g. 10 nF \u2192 1.2 ms clock). Charged/discharged by a 12 \u00b5A typical source/sink between VLTH (0.5 V) and VHTH (1.22 V)."+ "description": "Timer adjust. Connect an external timing capacitor from TADJ to GND to set the clock period (~120 µs/nF; e.g. 10 nF → 1.2 ms clock). Charged/discharged by a 12 µA typical source/sink between VLTH (0.5 V) and VHTH (1.22 V)." }, { "number": "6", "name": "FLAG3", "type": "output",- "description": "Open-drain output 3. Released last during power-up (after TD3) and pulled low first during power-down. VOL \u2264 0.4 V at 1.2 mA. Requires external pull-up. Leakage \u2264 1 \u00b5A at 3.3 V."+ "description": "Open-drain output 3. Released last during power-up (after TD3) and pulled low first during power-down. VOL ≤ 0.4 V at 1.2 mA. Requires external pull-up. Leakage ≤ 1 µA at 3.3 V." }, { "number": "7", "name": "FLAG2", "type": "output",- "description": "Open-drain output 2. Released after FLAG1 during power-up (after TD2) and pulled low after FLAG3 during power-down. VOL \u2264 0.4 V at 1.2 mA. Requires external pull-up."+ "description": "Open-drain output 2. Released after FLAG1 during power-up (after TD2) and pulled low after FLAG3 during power-down. VOL ≤ 0.4 V at 1.2 mA. Requires external pull-up." }, { "number": "8", "name": "FLAG1", "type": "output",- "description": "Open-drain output 1. Released first during power-up (after TD1 = 9-10 clock cycles) and pulled low last during power-down. VOL \u2264 0.4 V at 1.2 mA. Requires external pull-up."+ "description": "Open-drain output 1. Released first during power-up (after TD1 = 9-10 clock cycles) and pulled low last during power-down. VOL ≤ 0.4 V at 1.2 mA. Requires external pull-up." } ], "provenance": {@@ -138,5 +138,8 @@ "docs/lm3881mmx-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }