← Commit history

Set visibility: public

Ray ·1ef2c298c1 · ·parent 50ce9bc
1 file changed +9−6
page.json+9−6
@@ -32,7 +32,7 @@         "number": "1",         "name": "VCC",         "type": "power_in",-        "description": "Input supply pin. Recommended operating range 2.7 V to 5.5 V (absolute max 6 V). Typical quiescent current 25 \u00b5A. Bypass with a local decoupling capacitor to GND."+        "description": "Input supply pin. Recommended operating range 2.7 V to 5.5 V (absolute max 6 V). Typical quiescent current 25 µA. Bypass with a local decoupling capacitor to GND."       },       {         "number": "2",@@ -44,25 +44,25 @@         "number": "3",         "name": "EN",         "type": "input",-        "description": "Precision enable input. Threshold VEN typ 1.25 V (min 1.0 V, max 1.4 V) with a 7 \u00b5A internal pull-up current. Driving EN high starts the power-up sequence; pulling EN low starts the power-down sequence."+        "description": "Precision enable input. Threshold VEN typ 1.25 V (min 1.0 V, max 1.4 V) with a 7 µA internal pull-up current. Driving EN high starts the power-up sequence; pulling EN low starts the power-down sequence."       },       {         "number": "4",         "name": "FLAG3",         "type": "output",-        "description": "Open-drain sequenced output 3. Released last during power-up (after td3) and pulled low first during power-down. Drives the enable/shutdown pin of a downstream regulator. Absolute-max pull-up voltage 6 V (or VCC+0.3 V under recommended operation); VOL \u2264 0.4 V at IFLAG = 1.2 mA; max sink current 50 mA."+        "description": "Open-drain sequenced output 3. Released last during power-up (after td3) and pulled low first during power-down. Drives the enable/shutdown pin of a downstream regulator. Absolute-max pull-up voltage 6 V (or VCC+0.3 V under recommended operation); VOL ≤ 0.4 V at IFLAG = 1.2 mA; max sink current 50 mA."       },       {         "number": "5",         "name": "FLAG2",         "type": "output",-        "description": "Open-drain sequenced output 2. Released after FLAG1 (delay td2) during power-up and pulled low after FLAG3 during power-down. VOL \u2264 0.4 V at IFLAG = 1.2 mA; max sink current 50 mA; pull-up allowed to a separate rail up to 6 V absolute max."+        "description": "Open-drain sequenced output 2. Released after FLAG1 (delay td2) during power-up and pulled low after FLAG3 during power-down. VOL ≤ 0.4 V at IFLAG = 1.2 mA; max sink current 50 mA; pull-up allowed to a separate rail up to 6 V absolute max."       },       {         "number": "6",         "name": "FLAG1",         "type": "output",-        "description": "Open-drain sequenced output 1. Released first during power-up (after td1 from EN rising) and pulled low last during power-down. VOL \u2264 0.4 V at IFLAG = 1.2 mA; leakage typ 1 nA at 3.3 V; max sink current 50 mA."+        "description": "Open-drain sequenced output 1. Released first during power-up (after td1 from EN rising) and pulled low last during power-down. VOL ≤ 0.4 V at IFLAG = 1.2 mA; leakage typ 1 nA at 3.3 V; max sink current 50 mA."       }     ],     "provenance": {@@ -136,5 +136,8 @@     "docs/lm3880qmfx-1ad-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file