← Commit history

lm337kvurg3: specified limits as data (metadata.characteristics, 27 rows from the datasheet)

Ray ·d50c280027 · ·parent 79feb79
2 files changed +365
README.md+34
@@ -21,6 +21,40 @@ LM337KVURG3 from Texas Instruments, in a TO-252. Pinout and pin descriptions ext | Category | Power Management (PMIC) | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input regulation (TJ = 25°C) |  |  | 0.01 | 0.04 | %/V | TJ = 25°C, VI – VO = –3 V to –40 V | 5 |+| Input regulation (TJ = MIN to MAX) |  |  | 0.02 | 0.07 | %/V | VI – VO = –3 V to –40 V, TJ = MIN to MAX | 5 |+| Ripple rejection |  |  | 60 |  | dB | VO = –10 V, f = 120 Hz | 5 |+| Ripple rejection with CADJ |  | 66 | 77 |  | dB | VO = –10 V, f = 120 Hz, CADJ = 10 μF | 5 |+| Output regulation /VO/ ≤ 5 V |  |  |  | 50 | mV | IO = 10 mA to 1.5 A | 5 |+| Output regulation /VO/ ≥ 5 V |  |  | 0.3 | 1 | % | IO = 10 mA to 1.5 A | 5 |+| Output-voltage change with temperature |  |  | 0.6 |  | % | TJ = MIN to MAX | 5 |+| Output-voltage long-term drift |  |  | 0.3 | 1 | % | After 1000 h at TJ = MAX and VI – VO = –40 V | 5 |+| Output noise voltage |  |  | 0.003 |  | % | f = 10 Hz to 10 kHz, TJ = 25°C | 5 |+| Minimum output current to maintain regulation (/VI – VO/ ≤ 40 V) |  |  | 2.5 | 10 | mA | /VI – VO/ ≤ 40 V | 5 |+| Minimum output current to maintain regulation (/VI – VO/ ≤ 10 V) |  |  | 1.5 | 6 | mA | /VI – VO/ ≤ 10 V | 5 |+| Peak output current (/VI – VO/ ≤ 15 V) |  |  | 1.5 | 2.2 | A | /VI – VO/ ≤ 15 V | 5 |+| Peak output current (/VI – VO/ ≤ 40 V) |  |  | 0.15 | 0.4 | A | /VI – VO/ ≤ 40 V, TJ = 25°C | 5 |+| ADJUSTMENT current |  |  | 65 | 100 | μA |  | 5 |+| Change in ADJUSTMENT current |  |  | 2 | 5 | μA | VI – VO = –2.5 V to –40 V, IO = 10 mA to MAX, TJ = 25°C | 5 |+| Reference voltage (OUTPUT to ADJUSTMENT), TJ = 25°C |  | -1.213 | -1.25 | -1.287 | V | VI – VO = –3 V to –40 V, IO = 10 mA to 1.5 A, P ≤ rated dissipation, TJ = 25°C | 5 |+| Reference voltage (OUTPUT to ADJUSTMENT), TJ = MIN to MAX |  | -1.2 | -1.25 | -1.3 | V | VI – VO = –3 V to –40 V, IO = 10 mA to 1.5 A, P ≤ rated dissipation, TJ = MIN to MAX | 5 |+| Thermal regulation |  |  | 0.003 | 0.04 | %/W | Initial TJ = 25°C, 10-ms pulse | 5 |+| Input-to-output differential voltage (absolute maximum) | VI – VO | -40 |  |  | V |  | 4 |+| Operating virtual junction temperature (absolute maximum) | TJ |  |  | 150 | °C |  | 4 |+| Lead temperature (absolute maximum) |  |  |  | 260 | °C | 1.6 mm (1/16 in) from case for 10 s | 4 |+| Storage temperature range | Tstg | -65 |  | 150 | °C |  | 4 |+| Input-to-output differential voltage (recommended) | VI – VO | -2.5 |  | -37 | V |  | 4 |+| Output current (recommended, /VI – VO/ ≤ 40 V) | IO | 10 |  | 1500 | mA | /VI – VO/ ≤ 40 V, P ≤ 15 W | 4 |+| Output current (recommended, /VI – VO/ ≤ 10 V) | IO | 6 |  | 1500 | mA | /VI – VO/ ≤ 10 V, P ≤ 15 W | 4 |+| Operating virtual junction temperature (LM337) | TJ | 0 |  | 125 | °C | LM337 | 4 |+| Junction-to-ambient thermal resistance (KVU package) | RθJA |  | 30.3 |  | °C/W |  | 4 |+ ## CAD (KiCad official)  - Symbol: `LM337KVURG3`
page.json+331
@@ -133,6 +133,337 @@       "Package": "TO-252",       "Category": "Power Management (PMIC)",       "Pins": "3"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "9314cd867e85589c",+      "rows": [+        {+          "name": "Input regulation (TJ = 25°C)",+          "symbol": "",+          "kind": "electrical",+          "unit": "%/V",+          "min": null,+          "typ": 0.01,+          "max": 0.04,+          "conditions": "TJ = 25°C, VI – VO = –3 V to –40 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Input regulation (TJ = MIN to MAX)",+          "symbol": "",+          "kind": "electrical",+          "unit": "%/V",+          "min": null,+          "typ": 0.02,+          "max": 0.07,+          "conditions": "VI – VO = –3 V to –40 V, TJ = MIN to MAX",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Ripple rejection",+          "symbol": "",+          "kind": "electrical",+          "unit": "dB",+          "min": null,+          "typ": 60,+          "max": null,+          "conditions": "VO = –10 V, f = 120 Hz",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Ripple rejection with CADJ",+          "symbol": "",+          "kind": "electrical",+          "unit": "dB",+          "min": 66,+          "typ": 77,+          "max": null,+          "conditions": "VO = –10 V, f = 120 Hz, CADJ = 10 μF",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Output regulation |VO| ≤ 5 V",+          "symbol": "",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": null,+          "max": 50,+          "conditions": "IO = 10 mA to 1.5 A",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Output regulation |VO| ≥ 5 V",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": null,+          "typ": 0.3,+          "max": 1,+          "conditions": "IO = 10 mA to 1.5 A",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Output-voltage change with temperature",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": null,+          "typ": 0.6,+          "max": null,+          "conditions": "TJ = MIN to MAX",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Output-voltage long-term drift",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": null,+          "typ": 0.3,+          "max": 1,+          "conditions": "After 1000 h at TJ = MAX and VI – VO = –40 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Output noise voltage",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": null,+          "typ": 0.003,+          "max": null,+          "conditions": "f = 10 Hz to 10 kHz, TJ = 25°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Minimum output current to maintain regulation (|VI – VO| ≤ 40 V)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 2.5,+          "max": 10,+          "conditions": "|VI – VO| ≤ 40 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Minimum output current to maintain regulation (|VI – VO| ≤ 10 V)",+          "symbol": "",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 1.5,+          "max": 6,+          "conditions": "|VI – VO| ≤ 10 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Peak output current (|VI – VO| ≤ 15 V)",+          "symbol": "",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 1.5,+          "max": 2.2,+          "conditions": "|VI – VO| ≤ 15 V",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Peak output current (|VI – VO| ≤ 40 V)",+          "symbol": "",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 0.15,+          "max": 0.4,+          "conditions": "|VI – VO| ≤ 40 V, TJ = 25°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "ADJUSTMENT current",+          "symbol": "",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": 65,+          "max": 100,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Change in ADJUSTMENT current",+          "symbol": "",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": 2,+          "max": 5,+          "conditions": "VI – VO = –2.5 V to –40 V, IO = 10 mA to MAX, TJ = 25°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Reference voltage (OUTPUT to ADJUSTMENT), TJ = 25°C",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": -1.213,+          "typ": -1.25,+          "max": -1.287,+          "conditions": "VI – VO = –3 V to –40 V, IO = 10 mA to 1.5 A, P ≤ rated dissipation, TJ = 25°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Reference voltage (OUTPUT to ADJUSTMENT), TJ = MIN to MAX",+          "symbol": "",+          "kind": "electrical",+          "unit": "V",+          "min": -1.2,+          "typ": -1.25,+          "max": -1.3,+          "conditions": "VI – VO = –3 V to –40 V, IO = 10 mA to 1.5 A, P ≤ rated dissipation, TJ = MIN to MAX",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Thermal regulation",+          "symbol": "",+          "kind": "electrical",+          "unit": "%/W",+          "min": null,+          "typ": 0.003,+          "max": 0.04,+          "conditions": "Initial TJ = 25°C, 10-ms pulse",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Input-to-output differential voltage (absolute maximum)",+          "symbol": "VI – VO",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -40,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating virtual junction temperature (absolute maximum)",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Lead temperature (absolute maximum)",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "1.6 mm (1/16 in) from case for 10 s",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature range",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Input-to-output differential voltage (recommended)",+          "symbol": "VI – VO",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -2.5,+          "typ": null,+          "max": -37,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Output current (recommended, |VI – VO| ≤ 40 V)",+          "symbol": "IO",+          "kind": "recommended_operating",+          "unit": "mA",+          "min": 10,+          "typ": null,+          "max": 1500,+          "conditions": "|VI – VO| ≤ 40 V, P ≤ 15 W",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Output current (recommended, |VI – VO| ≤ 10 V)",+          "symbol": "IO",+          "kind": "recommended_operating",+          "unit": "mA",+          "min": 6,+          "typ": null,+          "max": 1500,+          "conditions": "|VI – VO| ≤ 10 V, P ≤ 15 W",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating virtual junction temperature (LM337)",+          "symbol": "TJ",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 0,+          "typ": null,+          "max": 125,+          "conditions": "LM337",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-ambient thermal resistance (KVU package)",+          "symbol": "RθJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 30.3,+          "max": null,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],