Texas Instruments Voltage Regulators - Linear, Low Drop Out (LDO) Regulators, TO-252. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.
← Commit history
lm337kvurg3: specified limits as data (metadata.characteristics, 27 rows from the datasheet)
2 files changed
+365
README.md+34@@ -21,6 +21,40 @@ LM337KVURG3 from Texas Instruments, in a TO-252. Pinout and pin descriptions ext | Category | Power Management (PMIC) | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input regulation (TJ = 25°C) | | | 0.01 | 0.04 | %/V | TJ = 25°C, VI – VO = –3 V to –40 V | 5 |+| Input regulation (TJ = MIN to MAX) | | | 0.02 | 0.07 | %/V | VI – VO = –3 V to –40 V, TJ = MIN to MAX | 5 |+| Ripple rejection | | | 60 | | dB | VO = –10 V, f = 120 Hz | 5 |+| Ripple rejection with CADJ | | 66 | 77 | | dB | VO = –10 V, f = 120 Hz, CADJ = 10 μF | 5 |+| Output regulation /VO/ ≤ 5 V | | | | 50 | mV | IO = 10 mA to 1.5 A | 5 |+| Output regulation /VO/ ≥ 5 V | | | 0.3 | 1 | % | IO = 10 mA to 1.5 A | 5 |+| Output-voltage change with temperature | | | 0.6 | | % | TJ = MIN to MAX | 5 |+| Output-voltage long-term drift | | | 0.3 | 1 | % | After 1000 h at TJ = MAX and VI – VO = –40 V | 5 |+| Output noise voltage | | | 0.003 | | % | f = 10 Hz to 10 kHz, TJ = 25°C | 5 |+| Minimum output current to maintain regulation (/VI – VO/ ≤ 40 V) | | | 2.5 | 10 | mA | /VI – VO/ ≤ 40 V | 5 |+| Minimum output current to maintain regulation (/VI – VO/ ≤ 10 V) | | | 1.5 | 6 | mA | /VI – VO/ ≤ 10 V | 5 |+| Peak output current (/VI – VO/ ≤ 15 V) | | | 1.5 | 2.2 | A | /VI – VO/ ≤ 15 V | 5 |+| Peak output current (/VI – VO/ ≤ 40 V) | | | 0.15 | 0.4 | A | /VI – VO/ ≤ 40 V, TJ = 25°C | 5 |+| ADJUSTMENT current | | | 65 | 100 | μA | | 5 |+| Change in ADJUSTMENT current | | | 2 | 5 | μA | VI – VO = –2.5 V to –40 V, IO = 10 mA to MAX, TJ = 25°C | 5 |+| Reference voltage (OUTPUT to ADJUSTMENT), TJ = 25°C | | -1.213 | -1.25 | -1.287 | V | VI – VO = –3 V to –40 V, IO = 10 mA to 1.5 A, P ≤ rated dissipation, TJ = 25°C | 5 |+| Reference voltage (OUTPUT to ADJUSTMENT), TJ = MIN to MAX | | -1.2 | -1.25 | -1.3 | V | VI – VO = –3 V to –40 V, IO = 10 mA to 1.5 A, P ≤ rated dissipation, TJ = MIN to MAX | 5 |+| Thermal regulation | | | 0.003 | 0.04 | %/W | Initial TJ = 25°C, 10-ms pulse | 5 |+| Input-to-output differential voltage (absolute maximum) | VI – VO | -40 | | | V | | 4 |+| Operating virtual junction temperature (absolute maximum) | TJ | | | 150 | °C | | 4 |+| Lead temperature (absolute maximum) | | | | 260 | °C | 1.6 mm (1/16 in) from case for 10 s | 4 |+| Storage temperature range | Tstg | -65 | | 150 | °C | | 4 |+| Input-to-output differential voltage (recommended) | VI – VO | -2.5 | | -37 | V | | 4 |+| Output current (recommended, /VI – VO/ ≤ 40 V) | IO | 10 | | 1500 | mA | /VI – VO/ ≤ 40 V, P ≤ 15 W | 4 |+| Output current (recommended, /VI – VO/ ≤ 10 V) | IO | 6 | | 1500 | mA | /VI – VO/ ≤ 10 V, P ≤ 15 W | 4 |+| Operating virtual junction temperature (LM337) | TJ | 0 | | 125 | °C | LM337 | 4 |+| Junction-to-ambient thermal resistance (KVU package) | RθJA | | 30.3 | | °C/W | | 4 |+ ## CAD (KiCad official) - Symbol: `LM337KVURG3`
page.json+331@@ -133,6 +133,337 @@ "Package": "TO-252", "Category": "Power Management (PMIC)", "Pins": "3"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "9314cd867e85589c",+ "rows": [+ {+ "name": "Input regulation (TJ = 25°C)",+ "symbol": "",+ "kind": "electrical",+ "unit": "%/V",+ "min": null,+ "typ": 0.01,+ "max": 0.04,+ "conditions": "TJ = 25°C, VI – VO = –3 V to –40 V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Input regulation (TJ = MIN to MAX)",+ "symbol": "",+ "kind": "electrical",+ "unit": "%/V",+ "min": null,+ "typ": 0.02,+ "max": 0.07,+ "conditions": "VI – VO = –3 V to –40 V, TJ = MIN to MAX",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Ripple rejection",+ "symbol": "",+ "kind": "electrical",+ "unit": "dB",+ "min": null,+ "typ": 60,+ "max": null,+ "conditions": "VO = –10 V, f = 120 Hz",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Ripple rejection with CADJ",+ "symbol": "",+ "kind": "electrical",+ "unit": "dB",+ "min": 66,+ "typ": 77,+ "max": null,+ "conditions": "VO = –10 V, f = 120 Hz, CADJ = 10 μF",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Output regulation |VO| ≤ 5 V",+ "symbol": "",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 50,+ "conditions": "IO = 10 mA to 1.5 A",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Output regulation |VO| ≥ 5 V",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": 0.3,+ "max": 1,+ "conditions": "IO = 10 mA to 1.5 A",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Output-voltage change with temperature",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": 0.6,+ "max": null,+ "conditions": "TJ = MIN to MAX",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Output-voltage long-term drift",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": 0.3,+ "max": 1,+ "conditions": "After 1000 h at TJ = MAX and VI – VO = –40 V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Output noise voltage",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": null,+ "typ": 0.003,+ "max": null,+ "conditions": "f = 10 Hz to 10 kHz, TJ = 25°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Minimum output current to maintain regulation (|VI – VO| ≤ 40 V)",+ "symbol": "",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 2.5,+ "max": 10,+ "conditions": "|VI – VO| ≤ 40 V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Minimum output current to maintain regulation (|VI – VO| ≤ 10 V)",+ "symbol": "",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 1.5,+ "max": 6,+ "conditions": "|VI – VO| ≤ 10 V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Peak output current (|VI – VO| ≤ 15 V)",+ "symbol": "",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 1.5,+ "max": 2.2,+ "conditions": "|VI – VO| ≤ 15 V",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Peak output current (|VI – VO| ≤ 40 V)",+ "symbol": "",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.15,+ "max": 0.4,+ "conditions": "|VI – VO| ≤ 40 V, TJ = 25°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "ADJUSTMENT current",+ "symbol": "",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": 65,+ "max": 100,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Change in ADJUSTMENT current",+ "symbol": "",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": 2,+ "max": 5,+ "conditions": "VI – VO = –2.5 V to –40 V, IO = 10 mA to MAX, TJ = 25°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Reference voltage (OUTPUT to ADJUSTMENT), TJ = 25°C",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": -1.213,+ "typ": -1.25,+ "max": -1.287,+ "conditions": "VI – VO = –3 V to –40 V, IO = 10 mA to 1.5 A, P ≤ rated dissipation, TJ = 25°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Reference voltage (OUTPUT to ADJUSTMENT), TJ = MIN to MAX",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": -1.2,+ "typ": -1.25,+ "max": -1.3,+ "conditions": "VI – VO = –3 V to –40 V, IO = 10 mA to 1.5 A, P ≤ rated dissipation, TJ = MIN to MAX",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Thermal regulation",+ "symbol": "",+ "kind": "electrical",+ "unit": "%/W",+ "min": null,+ "typ": 0.003,+ "max": 0.04,+ "conditions": "Initial TJ = 25°C, 10-ms pulse",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Input-to-output differential voltage (absolute maximum)",+ "symbol": "VI – VO",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -40,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Operating virtual junction temperature (absolute maximum)",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Lead temperature (absolute maximum)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "1.6 mm (1/16 in) from case for 10 s",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature range",+ "symbol": "Tstg",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Input-to-output differential voltage (recommended)",+ "symbol": "VI – VO",+ "kind": "recommended_operating",+ "unit": "V",+ "min": -2.5,+ "typ": null,+ "max": -37,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Output current (recommended, |VI – VO| ≤ 40 V)",+ "symbol": "IO",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": 10,+ "typ": null,+ "max": 1500,+ "conditions": "|VI – VO| ≤ 40 V, P ≤ 15 W",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Output current (recommended, |VI – VO| ≤ 10 V)",+ "symbol": "IO",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": 6,+ "typ": null,+ "max": 1500,+ "conditions": "|VI – VO| ≤ 10 V, P ≤ 15 W",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Operating virtual junction temperature (LM337)",+ "symbol": "TJ",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 125,+ "conditions": "LM337",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-ambient thermal resistance (KVU package)",+ "symbol": "RθJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 30.3,+ "max": null,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ }+ ] } }, "variants": [],