← Commit history

lm317bd2tr4g: specified limits as data (metadata.characteristics, 19 rows from the datasheet)

Ray ·c0cde70b5e ·17d ago ·parent 72c9d04
2 files changed +262−1
README.md+26
@@ -21,6 +21,32 @@ LM317BD2TR4G from onsemi, in a TO-263-2. Pinout and pin descriptions extracted f | Category | Power Management (PMIC) | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Line Regulation (Note 3), TA = +25°C, 3.0 V ≤ VI−VO ≤ 40 V | Regline |  | 0.01 | 0.04 | %/V | TA = +25°C, 3.0 V ≤ VI−VO ≤ 40 V | 2 |+| Load Regulation (Note 3), VO ≤ 5.0 V | Regload |  | 5 | 25 | mV | TA = +25°C, 10 mA ≤ IO ≤ Imax | 2 |+| Load Regulation (Note 3), VO ≥ 5.0 V | Regload |  | 0.1 | 0.5 | % VO | TA = +25°C, 10 mA ≤ IO ≤ Imax | 2 |+| Thermal Regulation, 20 ms Pulse | Regtherm |  | 0.03 | 0.07 | % VO/W | TA = +25°C (Note 4), 20 ms Pulse | 2 |+| Adjustment Pin Current | IAdj |  | 50 | 100 | µA |  | 2 |+| Adjustment Pin Current Change | IAdj |  | 0.2 | 5 | µA | 2.5 V ≤ VI−VO ≤ 40 V, 10 mA ≤ IL ≤ Imax, PD ≤ Pmax | 2 |+| Reference Voltage | Vref | 1.2 | 1.25 | 1.3 | V | 3.0 V ≤ VI−VO ≤ 40 V, 10 mA ≤ IO ≤ Imax, PD ≤ Pmax | 2 |+| Line Regulation (Note 3) | Regline |  | 0.02 | 0.07 | % V | 3.0 V ≤ VI−VO ≤ 40 V | 2 |+| Load Regulation (Note 3), VO ≤ 5.0 V | Regload |  | 20 | 70 | mV | 10 mA ≤ IO ≤ Imax | 2 |+| Load Regulation (Note 3), VO ≥ 5.0 V | Regload |  | 0.3 | 1.5 | % VO | 10 mA ≤ IO ≤ Imax | 2 |+| Minimum Load Current to Maintain Regulation | ILmin |  | 3.5 | 10 | mA | VI−VO = 40 V | 2 |+| Maximum Output Current | Imax | 1.5 | 2.2 |  | A | VI−VO ≤ 15 V, PD ≤ Pmax, T Package | 2 |+| Maximum Output Current | Imax | 0.15 | 0.4 |  | A | VI−VO = 40 V, PD ≤ Pmax, TA = +25°C, T Package | 2 |+| Long-Term Stability | S |  | 0.3 | 1 | %/1.0 kHrs. | TJ = Thigh (Note 7), TA = +25°C for Endpoint Measurements | 2 |+| Input-Output Voltage Differential | VI−VO | -0.3 |  | 40 | Vdc |  | 2 |+| Thermal Resistance, Junction-to-Ambient (Case 936, D2PAK-3) | JA |  | 70 |  | °C/W | Case 936 (D2PAK-3) | 2 |+| Thermal Resistance, Junction-to-Case (Case 936, D2PAK-3) | JC |  | 5 |  | °C/W | Case 936 (D2PAK-3) | 2 |+| Operating Junction Temperature Range | TJ | -55 |  | 150 | °C |  | 2 |+| Storage Temperature Range | Tstg | -65 |  | 150 | °C |  | 2 |+ ## CAD (KiCad official)  - Symbol: `LM317BD2TR4G`
page.json+236−1
@@ -149,6 +149,241 @@       "Package": "TO-263-2",       "Category": "Power Management (PMIC)",       "Pins": "3"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "752b2a8373998f8d",+      "rows": [+        {+          "name": "Line Regulation (Note 3), TA = +25°C, 3.0 V ≤ VI−VO ≤ 40 V",+          "symbol": "Regline",+          "kind": "electrical",+          "unit": "%/V",+          "min": null,+          "typ": 0.01,+          "max": 0.04,+          "conditions": "TA = +25°C, 3.0 V ≤ VI−VO ≤ 40 V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Load Regulation (Note 3), VO ≤ 5.0 V",+          "symbol": "Regload",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": 5,+          "max": 25,+          "conditions": "TA = +25°C, 10 mA ≤ IO ≤ Imax",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Load Regulation (Note 3), VO ≥ 5.0 V",+          "symbol": "Regload",+          "kind": "electrical",+          "unit": "% VO",+          "min": null,+          "typ": 0.1,+          "max": 0.5,+          "conditions": "TA = +25°C, 10 mA ≤ IO ≤ Imax",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Thermal Regulation, 20 ms Pulse",+          "symbol": "Regtherm",+          "kind": "thermal",+          "unit": "% VO/W",+          "min": null,+          "typ": 0.03,+          "max": 0.07,+          "conditions": "TA = +25°C (Note 4), 20 ms Pulse",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Adjustment Pin Current",+          "symbol": "IAdj",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": 50,+          "max": 100,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Adjustment Pin Current Change",+          "symbol": "IAdj",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": 0.2,+          "max": 5,+          "conditions": "2.5 V ≤ VI−VO ≤ 40 V, 10 mA ≤ IL ≤ Imax, PD ≤ Pmax",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reference Voltage",+          "symbol": "Vref",+          "kind": "electrical",+          "unit": "V",+          "min": 1.2,+          "typ": 1.25,+          "max": 1.3,+          "conditions": "3.0 V ≤ VI−VO ≤ 40 V, 10 mA ≤ IO ≤ Imax, PD ≤ Pmax",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Line Regulation (Note 3)",+          "symbol": "Regline",+          "kind": "electrical",+          "unit": "% V",+          "min": null,+          "typ": 0.02,+          "max": 0.07,+          "conditions": "3.0 V ≤ VI−VO ≤ 40 V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Load Regulation (Note 3), VO ≤ 5.0 V",+          "symbol": "Regload",+          "kind": "electrical",+          "unit": "mV",+          "min": null,+          "typ": 20,+          "max": 70,+          "conditions": "10 mA ≤ IO ≤ Imax",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Load Regulation (Note 3), VO ≥ 5.0 V",+          "symbol": "Regload",+          "kind": "electrical",+          "unit": "% VO",+          "min": null,+          "typ": 0.3,+          "max": 1.5,+          "conditions": "10 mA ≤ IO ≤ Imax",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Minimum Load Current to Maintain Regulation",+          "symbol": "ILmin",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 3.5,+          "max": 10,+          "conditions": "VI−VO = 40 V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum Output Current",+          "symbol": "Imax",+          "kind": "electrical",+          "unit": "A",+          "min": 1.5,+          "typ": 2.2,+          "max": null,+          "conditions": "VI−VO ≤ 15 V, PD ≤ Pmax, T Package",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum Output Current",+          "symbol": "Imax",+          "kind": "electrical",+          "unit": "A",+          "min": 0.15,+          "typ": 0.4,+          "max": null,+          "conditions": "VI−VO = 40 V, PD ≤ Pmax, TA = +25°C, T Package",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Long-Term Stability",+          "symbol": "S",+          "kind": "electrical",+          "unit": "%/1.0 kHrs.",+          "min": null,+          "typ": 0.3,+          "max": 1,+          "conditions": "TJ = Thigh (Note 7), TA = +25°C for Endpoint Measurements",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Input-Output Voltage Differential",+          "symbol": "VI−VO",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": -0.3,+          "typ": null,+          "max": 40,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Thermal Resistance, Junction-to-Ambient (Case 936, D2PAK-3)",+          "symbol": "JA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 70,+          "max": null,+          "conditions": "Case 936 (D2PAK-3)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Thermal Resistance, Junction-to-Case (Case 936, D2PAK-3)",+          "symbol": "JC",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 5,+          "max": null,+          "conditions": "Case 936 (D2PAK-3)",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Operating Junction Temperature Range",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage Temperature Range",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -65,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -190,4 +425,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}