← Commit history
page.json+8−5@@ -32,7 +32,7 @@ "number": "1", "name": "HYST", "type": "input",- "description": "Hysteresis control digital input. Tie to GND to select 10\u00b0C hysteresis (typ 11\u00b0C) or to V+ to select 2\u00b0C hysteresis."+ "description": "Hysteresis control digital input. Tie to GND to select 10°C hysteresis (typ 11°C) or to V+ to select 2°C hysteresis." }, { "number": "2",@@ -44,19 +44,19 @@ "number": "3", "name": "VTEMP", "type": "output",- "description": "Analog output voltage proportional to temperature (slope approximately -10.82 mV/\u00b0C). Leave floating or connect to a high-impedance node for after-assembly system testing."+ "description": "Analog output voltage proportional to temperature (slope approximately -10.82 mV/°C). Leave floating or connect to a high-impedance node for after-assembly system testing." }, { "number": "4", "name": "V+", "type": "power_in",- "description": "Positive supply input. Connect to 2.7 V to 5.5 V with a 0.1 \u00b5F bypass capacitor. Typical supply current 16 \u00b5A (max 40 \u00b5A)."+ "description": "Positive supply input. Connect to 2.7 V to 5.5 V with a 0.1 µF bypass capacitor. Typical supply current 16 µA (max 40 µA)." }, { "number": "5", "name": "US", "type": "output",- "description": "Undertemperature Shutdown push-pull, active-HIGH thermostat digital output (HHD variant, factory trip point 0\u00b0C). Drives HIGH when die temperature falls below the preset TUS trip point. Connect to controller interrupt or system/power-supply shutdown."+ "description": "Undertemperature Shutdown push-pull, active-HIGH thermostat digital output (HHD variant, factory trip point 0°C). Drives HIGH when die temperature falls below the preset TUS trip point. Connect to controller interrupt or system/power-supply shutdown." } ], "provenance": {@@ -130,5 +130,8 @@ "docs/lm26cim5x-hhd-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }