← Commit history
page.json+7−4@@ -56,7 +56,7 @@ "number": "5", "name": "EN", "type": "input",- "description": "Precision enable input. Used to control regulator start-up and shutdown; VEN threshold typ 1.6 V (falling), hysteresis ~0.6 V. Absolute max -0.5 V to 6 V; input current ~6 \u00b5A at 0 V."+ "description": "Precision enable input. Used to control regulator start-up and shutdown; VEN threshold typ 1.6 V (falling), hysteresis ~0.6 V. Absolute max -0.5 V to 6 V; input current ~6 µA at 0 V." }, { "number": "6",@@ -74,13 +74,13 @@ "number": "8", "name": "SW", "type": "power_out",- "description": "Switching output of the regulator. Connects to the external inductor and catch diode of the buck power stage. SW to GND DC rating -5 V to VIN (transient -10 V for \u226450 ns)."+ "description": "Switching output of the regulator. Connects to the external inductor and catch diode of the buck power stage. SW to GND DC rating -5 V to VIN (transient -10 V for ≤50 ns)." }, { "number": "EP", "name": "EP", "type": "power_in",- "description": "Exposed thermal pad on the underside of the SO PowerPAD package. Must be connected to ground and to a copper pour on the PCB for thermal dissipation (\u03b8JA \u2248 60 \u00b0C/W with 1 sq inch of copper)."+ "description": "Exposed thermal pad on the underside of the SO PowerPAD package. Must be connected to ground and to a copper pour on the PCB for thermal dissipation (θJA ≈ 60 °C/W with 1 sq inch of copper)." } ], "provenance": {@@ -144,5 +144,8 @@ "docs/lm22676mrx-adj-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }