← Commit history
l78l09acd13tr: specified limits as data (metadata.characteristics, 19 rows from the datasheet)
2 files changed
+262−1
README.md+26@@ -26,6 +26,32 @@ L78L09ACD13TR from STMicroelectronics, in a SO-8. Pinout and pin descriptions ex | Category | Power Management (PMIC) | | Pins | 8 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Output voltage | VO | 8.64 | 9 | 9.36 | V | TJ = 25 °C | 11 |+| Output voltage | VO | 8.55 | | 9.45 | V | IO = 1 to 40 mA, VI = 11.5 to 23 V | 11 |+| Line regulation | ∆VO | | | 225 | mV | VI = 11.5 to 23 V, TJ = 25 °C | 11 |+| Line regulation | ∆VO | | | 150 | mV | VI = 12 to 23 V, TJ = 25 °C | 11 |+| Load regulation | ∆VO | | | 80 | mV | IO = 1 to 100 mA, TJ = 25 °C | 11 |+| Load regulation | ∆VO | | | 40 | mV | IO = 1 to 40 mA, TJ = 25 °C | 11 |+| Quiescent current | Id | | | 6 | mA | TJ = 25 °C | 11 |+| Quiescent current | Id | | | 5.5 | mA | TJ = 125 °C | 11 |+| Quiescent current change | ∆Id | | | 0.1 | mA | IO = 1 to 40 mA | 11 |+| Quiescent current change | ∆Id | | | 1.5 | mA | VI = 12 to 23 V | 11 |+| Output noise voltage | eN | | | 70 | µV | B = 10 Hz to 100 kHz, TJ = 25 °C | 11 |+| Supply voltage rejection | SVR | 37 | 44 | | dB | VI = 12 to 23 V, f = 120 Hz, IO = 40 mA, TJ = 25 °C | 11 |+| Dropout voltage | Vd | | | 1.7 | V | | 11 |+| Input voltage (DC), VO = 3.3 to 9 V | VI | | | 30 | V | VO = 3.3 to 9 V | 4 |+| Output current | IO | | | 100 | mA | | 4 |+| Storage temperature range | TSTG | -65 | | 150 | °C | | 4 |+| Operating junction temperature range | TOP | 0 | | 125 | °C | for L78LxxAC / L78LxxC | 4 |+| Thermal resistance junction-case (max), SO-8 | RthJC | | | 20 | °C/W | | 4 |+| Thermal resistance junction-ambient (max), SO-8 | RthJA | | | 55 | °C/W | considering 6 cm² of copper board heat-sink | 4 |+ ## CAD (KiCad official) - Symbol: `L78L09ACD13TR`
page.json+236−1@@ -180,6 +180,241 @@ "Package": "SO-8", "Category": "Power Management (PMIC)", "Pins": "8"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "8b73c521b7f1b36e",+ "rows": [+ {+ "name": "Output voltage",+ "symbol": "VO",+ "kind": "electrical",+ "unit": "V",+ "min": 8.64,+ "typ": 9,+ "max": 9.36,+ "conditions": "TJ = 25 °C",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Output voltage",+ "symbol": "VO",+ "kind": "electrical",+ "unit": "V",+ "min": 8.55,+ "typ": null,+ "max": 9.45,+ "conditions": "IO = 1 to 40 mA, VI = 11.5 to 23 V",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Line regulation",+ "symbol": "∆VO",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 225,+ "conditions": "VI = 11.5 to 23 V, TJ = 25 °C",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Line regulation",+ "symbol": "∆VO",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "VI = 12 to 23 V, TJ = 25 °C",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Load regulation",+ "symbol": "∆VO",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 80,+ "conditions": "IO = 1 to 100 mA, TJ = 25 °C",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Load regulation",+ "symbol": "∆VO",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "IO = 1 to 40 mA, TJ = 25 °C",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current",+ "symbol": "Id",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "TJ = 25 °C",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current",+ "symbol": "Id",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 5.5,+ "conditions": "TJ = 125 °C",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current change",+ "symbol": "∆Id",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 0.1,+ "conditions": "IO = 1 to 40 mA",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current change",+ "symbol": "∆Id",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 1.5,+ "conditions": "VI = 12 to 23 V",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Output noise voltage",+ "symbol": "eN",+ "kind": "electrical",+ "unit": "µV",+ "min": null,+ "typ": null,+ "max": 70,+ "conditions": "B = 10 Hz to 100 kHz, TJ = 25 °C",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage rejection",+ "symbol": "SVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 37,+ "typ": 44,+ "max": null,+ "conditions": "VI = 12 to 23 V, f = 120 Hz, IO = 40 mA, TJ = 25 °C",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Dropout voltage",+ "symbol": "Vd",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 1.7,+ "conditions": "",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Input voltage (DC), VO = 3.3 to 9 V",+ "symbol": "VI",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "VO = 3.3 to 9 V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Output current",+ "symbol": "IO",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 100,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature range",+ "symbol": "TSTG",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature range",+ "symbol": "TOP",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 125,+ "conditions": "for L78LxxAC / L78LxxC",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance junction-case (max), SO-8",+ "symbol": "RthJC",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance junction-ambient (max), SO-8",+ "symbol": "RthJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": null,+ "max": 55,+ "conditions": "considering 6 cm² of copper board heat-sink",+ "source_page": 4,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -221,4 +456,4 @@ "visibility": { "public": true }-}+}