l78l06abutr: specified limits as data (metadata.characteristics, 18 rows from the datasheet)
2 files changed
+248
README.md+25@@ -33,6 +33,31 @@ Same part, different packaging or reel option. - `L78L06ABUTRD-TR` - `L78L06ABUTR13TR` +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Output voltage (TJ = 25 °C) | VO | 5.76 | 6 | 6.24 | V | TJ = 25 °C | 17 |+| Output voltage | VO | 5.7 | | 6.3 | V | IO = 1 to 40 mA, VI = 8.5 to 20 V | 17 |+| Line regulation | ∆VO | | | 150 | mV | VI = 8.5 to 20 V, TJ = 25 °C | 17 |+| Line regulation | ∆VO | | | 100 | mV | VI = 9 to 20 V, TJ = 25 °C | 17 |+| Load regulation | ∆VO | | | 60 | mV | IO = 1 to 100 mA, TJ = 25 °C | 17 |+| Load regulation | ∆VO | | | 30 | mV | IO = 1 to 40 mA, TJ = 25 °C | 17 |+| Quiescent current | Id | | | 6 | mA | TJ = 25 °C | 17 |+| Quiescent current | Id | | | 5.5 | mA | TJ = 125 °C | 17 |+| Quiescent current change | ∆Id | | | 0.1 | mA | IO = 1 to 40 mA | 17 |+| Quiescent current change | ∆Id | | | 1.5 | mA | VI = 9 to 20 V | 17 |+| Output noise voltage | eN | | | 50 | µV | B = 10 Hz to 100 kHz, TJ = 25 °C | 17 |+| Supply voltage rejection | SVR | 39 | 46 | | dB | VI = 9 to 20 V, f = 120 Hz, IO = 40 mA, TJ = 25 °C | 17 |+| Dropout voltage | Vd | | | 1.7 | V | | 17 |+| DC input voltage | VI | | | 30 | V | VO = 3.3 to 9 V (applies to 6 V output) | 5 |+| Output current | IO | | | 100 | mA | | 5 |+| Storage temperature range | TSTG | -65 | | 150 | °C | | 5 |+| Operating junction temperature range | TOP | -40 | | 125 | °C | for L78LxxAB | 5 |+| Thermal resistance junction-ambient (SOT-89) | RthJA | | | 55 | °C/W | Considering 6 cm² of copper board heat-sink | 5 |+ ## CAD (KiCad official) - Symbol: `L78L06ABUTR`
page.json+223@@ -130,6 +130,229 @@ "Package": "SOT-89-3", "Category": "PMIC", "Pins": "3"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "43922ae159face7e",+ "rows": [+ {+ "name": "Output voltage (TJ = 25 °C)",+ "symbol": "VO",+ "kind": "electrical",+ "unit": "V",+ "min": 5.76,+ "typ": 6,+ "max": 6.24,+ "conditions": "TJ = 25 °C",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Output voltage",+ "symbol": "VO",+ "kind": "electrical",+ "unit": "V",+ "min": 5.7,+ "typ": null,+ "max": 6.3,+ "conditions": "IO = 1 to 40 mA, VI = 8.5 to 20 V",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Line regulation",+ "symbol": "∆VO",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "VI = 8.5 to 20 V, TJ = 25 °C",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Line regulation",+ "symbol": "∆VO",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 100,+ "conditions": "VI = 9 to 20 V, TJ = 25 °C",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Load regulation",+ "symbol": "∆VO",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 60,+ "conditions": "IO = 1 to 100 mA, TJ = 25 °C",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Load regulation",+ "symbol": "∆VO",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "IO = 1 to 40 mA, TJ = 25 °C",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current",+ "symbol": "Id",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "TJ = 25 °C",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current",+ "symbol": "Id",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 5.5,+ "conditions": "TJ = 125 °C",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current change",+ "symbol": "∆Id",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 0.1,+ "conditions": "IO = 1 to 40 mA",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current change",+ "symbol": "∆Id",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 1.5,+ "conditions": "VI = 9 to 20 V",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Output noise voltage",+ "symbol": "eN",+ "kind": "electrical",+ "unit": "µV",+ "min": null,+ "typ": null,+ "max": 50,+ "conditions": "B = 10 Hz to 100 kHz, TJ = 25 °C",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage rejection",+ "symbol": "SVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 39,+ "typ": 46,+ "max": null,+ "conditions": "VI = 9 to 20 V, f = 120 Hz, IO = 40 mA, TJ = 25 °C",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "Dropout voltage",+ "symbol": "Vd",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 1.7,+ "conditions": "",+ "source_page": 17,+ "source": "datasheet"+ },+ {+ "name": "DC input voltage",+ "symbol": "VI",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 30,+ "conditions": "VO = 3.3 to 9 V (applies to 6 V output)",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Output current",+ "symbol": "IO",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 100,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature range",+ "symbol": "TSTG",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature range",+ "symbol": "TOP",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "for L78LxxAB",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance junction-ambient (SOT-89)",+ "symbol": "RthJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": null,+ "max": 55,+ "conditions": "Considering 6 cm² of copper board heat-sink",+ "source_page": 5,+ "source": "datasheet"+ }+ ] } }, "sections": [