knsmd100-16-hero.overlay.json+3−3
@@ -66,14 +66,14 @@     "seating_z_mm": -0.0   },   "sources": {-    "glb": "knsmd100-etched.glb",-    "glb_sha256": "0cdbe1f1ce1345d4d7f4f684a451398becac8735414270910aaed20633d3c4a4",+    "glb": "knsmd100.glb",+    "glb_sha256": "a997248b57cf31da5a22aae67f8b41afc7c735349b879a46945cc2396bfcdecb",     "footprint": "knsmd100.kicad_mod",     "footprint_sha256": "8f4307d8c771db71526ed8ccf7c762824636660adec3635905932cc5e1d02280",     "pins": "page.json component.pins",     "pins_sha256": "f89b6cef1dd40bf094bc57ef23dc246a408922a81bfac75b8bc341584ea4e214"   },-  "generator": "adom-wiki 1.8.22 (component_hero)",+  "generator": "adom-wiki 1.8.25 (component_hero)",   "labels": [     {       "pad": "1",
package.json+359−4
@@ -1,6 +1,6 @@ {   "slug": "knsmd100-16",-  "version": "0.1.1",+  "version": "0.1.2",   "type": "component",   "description": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",   "tags": [@@ -29,8 +29,6 @@     "viewers/footprint.html",     "knsmd100-hero.glb",     "knsmd100-hero.overlay.json",-    "knsmd100-etched.glb",-    "knsmd100-etched.step",     "knsmd100-16-hero.glb",     "knsmd100-16-hero.overlay.json"   ],@@ -165,5 +163,362 @@       "note": "renamed from the cut-base slug to the part it was built from (slug collision split, 2026-11-11)"     }   },-  "visibility": "public"+  "visibility": "public",+  "title": "KNSMD100/16",+  "brief": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "KUU",+      "Package": "1206",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "6b5f1960aeca8579e230e2d0c6db25edcf092d5e5f983153439911fbc75df372",+      "rows": [+        {+          "name": "Holding current",+          "symbol": "IH",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "25℃ still air",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Tripping current",+          "symbol": "IT",+          "kind": "electrical",+          "unit": "A",+          "min": 2,+          "typ": null,+          "max": null,+          "conditions": "25℃ still air",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Minimum resistance prior to trip",+          "symbol": "R min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.06,+          "typ": null,+          "max": null,+          "conditions": "25℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum resistance one hour post reflow",+          "symbol": "R1max",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 0.28,+          "conditions": "measured one hours post reflow at 25℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage withstand",+          "symbol": "Vmax",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 16,+          "conditions": "at rated current",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current withstand",+          "symbol": "I max",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 100,+          "conditions": "at rated voltage",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum time to trip",+          "symbol": "Ttrip",+          "kind": "electrical",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "at assigned current 8.00 A",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Reflow average ramp-up rate",+          "symbol": "",+          "kind": "thermal",+          "unit": "℃/second",+          "min": null,+          "typ": null,+          "max": 3,+          "conditions": "average ramp-up rate in reflow profile",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Reflow ramp-down rate",+          "symbol": "",+          "kind": "thermal",+          "unit": "℃/second",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "ramp-down rate in reflow profile",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Rated working power",+          "symbol": "Pd",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.6,+          "max": null,+          "conditions": "rated working power",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Hold current at maximum ambient",+          "symbol": "IH",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 1.6,+          "max": null,+          "conditions": "maximum ambient operating temperature -40℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Hold current at maximum ambient",+          "symbol": "IH",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 1.4,+          "max": null,+          "conditions": "maximum ambient operating temperature -20℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Hold current at maximum ambient",+          "symbol": "IH",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 1.3,+          "max": null,+          "conditions": "maximum ambient operating temperature 0℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Hold current at maximum ambient",+          "symbol": "IH",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 1,+          "max": null,+          "conditions": "maximum ambient operating temperature 25℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Hold current at maximum ambient",+          "symbol": "IH",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.9,+          "max": null,+          "conditions": "maximum ambient operating temperature 40℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Hold current at maximum ambient",+          "symbol": "IH",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.8,+          "max": null,+          "conditions": "maximum ambient operating temperature 50℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Hold current at maximum ambient",+          "symbol": "IH",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.75,+          "max": null,+          "conditions": "maximum ambient operating temperature 60℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Hold current at maximum ambient",+          "symbol": "IH",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.7,+          "max": null,+          "conditions": "maximum ambient operating temperature 70℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Hold current at maximum ambient",+          "symbol": "IH",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 0.6,+          "max": null,+          "conditions": "maximum ambient operating temperature 85℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current at maximum ambient",+          "symbol": "IT",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 3.2,+          "max": null,+          "conditions": "maximum ambient operating temperature -40℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current at maximum ambient",+          "symbol": "IT",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 2.8,+          "max": null,+          "conditions": "maximum ambient operating temperature -20℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current at maximum ambient",+          "symbol": "IT",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 2.6,+          "max": null,+          "conditions": "maximum ambient operating temperature 0℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current at maximum ambient",+          "symbol": "IT",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 2,+          "max": null,+          "conditions": "maximum ambient operating temperature 25℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current at maximum ambient",+          "symbol": "IT",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 1.8,+          "max": null,+          "conditions": "maximum ambient operating temperature 40℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current at maximum ambient",+          "symbol": "IT",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 1.6,+          "max": null,+          "conditions": "maximum ambient operating temperature 50℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current at maximum ambient",+          "symbol": "IT",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 1.5,+          "max": null,+          "conditions": "maximum ambient operating temperature 60℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current at maximum ambient",+          "symbol": "IT",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 1.4,+          "max": null,+          "conditions": "maximum ambient operating temperature 70℃",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current at maximum ambient",+          "symbol": "IT",+          "kind": "recommended_operating",+          "unit": "A",+          "min": null,+          "typ": 1.2,+          "max": null,+          "conditions": "maximum ambient operating temperature 85℃",+          "source_page": 1,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "knsmd100"+  ],+  "discovery_pitch": "KNSMD100 (KUU) component page: datasheet pinout, KiCad symbol, footprint and 3D." }
page.json+2−4
@@ -4,7 +4,7 @@   "slug": "knsmd100-16",   "title": "KNSMD100/16",   "brief": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",-  "version": "0.1.1",+  "version": "0.1.2",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -529,12 +529,10 @@     "viewers/footprint.html",     "knsmd100-hero.glb",     "knsmd100-hero.overlay.json",-    "knsmd100-etched.glb",-    "knsmd100-etched.step",     "knsmd100-16-hero.glb",     "knsmd100-16-hero.overlay.json"   ],   "visibility": "public",   "description": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",   "org": "adom"-}+}\ No newline at end of file