← Commit history
Publish 0.1.2
4 files changed
+364−11
knsmd100-16-hero.glb⋯ 1 unchanged line ⋯
knsmd100-16-hero.overlay.json+3−3@@ -66,14 +66,14 @@ "seating_z_mm": -0.0 }, "sources": {- "glb": "knsmd100-etched.glb",- "glb_sha256": "0cdbe1f1ce1345d4d7f4f684a451398becac8735414270910aaed20633d3c4a4",+ "glb": "knsmd100.glb",+ "glb_sha256": "a997248b57cf31da5a22aae67f8b41afc7c735349b879a46945cc2396bfcdecb", "footprint": "knsmd100.kicad_mod", "footprint_sha256": "8f4307d8c771db71526ed8ccf7c762824636660adec3635905932cc5e1d02280", "pins": "page.json component.pins", "pins_sha256": "f89b6cef1dd40bf094bc57ef23dc246a408922a81bfac75b8bc341584ea4e214" },- "generator": "adom-wiki 1.8.22 (component_hero)",+ "generator": "adom-wiki 1.8.25 (component_hero)", "labels": [ { "pad": "1",
package.json+359−4@@ -1,6 +1,6 @@ { "slug": "knsmd100-16",- "version": "0.1.1",+ "version": "0.1.2", "type": "component", "description": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "tags": [@@ -29,8 +29,6 @@ "viewers/footprint.html", "knsmd100-hero.glb", "knsmd100-hero.overlay.json",- "knsmd100-etched.glb",- "knsmd100-etched.step", "knsmd100-16-hero.glb", "knsmd100-16-hero.overlay.json" ],@@ -165,5 +163,362 @@ "note": "renamed from the cut-base slug to the part it was built from (slug collision split, 2026-11-11)" } },- "visibility": "public"+ "visibility": "public",+ "title": "KNSMD100/16",+ "brief": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "KUU",+ "Package": "1206",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "6b5f1960aeca8579e230e2d0c6db25edcf092d5e5f983153439911fbc75df372",+ "rows": [+ {+ "name": "Holding current",+ "symbol": "IH",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "25℃ still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Tripping current",+ "symbol": "IT",+ "kind": "electrical",+ "unit": "A",+ "min": 2,+ "typ": null,+ "max": null,+ "conditions": "25℃ still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Minimum resistance prior to trip",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 0.06,+ "typ": null,+ "max": null,+ "conditions": "25℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance one hour post reflow",+ "symbol": "R1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 0.28,+ "conditions": "measured one hours post reflow at 25℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage withstand",+ "symbol": "Vmax",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 16,+ "conditions": "at rated current",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current withstand",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 100,+ "conditions": "at rated voltage",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum time to trip",+ "symbol": "Ttrip",+ "kind": "electrical",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 0.1,+ "conditions": "at assigned current 8.00 A",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Reflow average ramp-up rate",+ "symbol": "",+ "kind": "thermal",+ "unit": "℃/second",+ "min": null,+ "typ": null,+ "max": 3,+ "conditions": "average ramp-up rate in reflow profile",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Reflow ramp-down rate",+ "symbol": "",+ "kind": "thermal",+ "unit": "℃/second",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "ramp-down rate in reflow profile",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Rated working power",+ "symbol": "Pd",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.6,+ "max": null,+ "conditions": "rated working power",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current at maximum ambient",+ "symbol": "IH",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 1.6,+ "max": null,+ "conditions": "maximum ambient operating temperature -40℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current at maximum ambient",+ "symbol": "IH",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 1.4,+ "max": null,+ "conditions": "maximum ambient operating temperature -20℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current at maximum ambient",+ "symbol": "IH",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 1.3,+ "max": null,+ "conditions": "maximum ambient operating temperature 0℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current at maximum ambient",+ "symbol": "IH",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 1,+ "max": null,+ "conditions": "maximum ambient operating temperature 25℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current at maximum ambient",+ "symbol": "IH",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 0.9,+ "max": null,+ "conditions": "maximum ambient operating temperature 40℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current at maximum ambient",+ "symbol": "IH",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 0.8,+ "max": null,+ "conditions": "maximum ambient operating temperature 50℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current at maximum ambient",+ "symbol": "IH",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 0.75,+ "max": null,+ "conditions": "maximum ambient operating temperature 60℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current at maximum ambient",+ "symbol": "IH",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 0.7,+ "max": null,+ "conditions": "maximum ambient operating temperature 70℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current at maximum ambient",+ "symbol": "IH",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 0.6,+ "max": null,+ "conditions": "maximum ambient operating temperature 85℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current at maximum ambient",+ "symbol": "IT",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 3.2,+ "max": null,+ "conditions": "maximum ambient operating temperature -40℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current at maximum ambient",+ "symbol": "IT",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 2.8,+ "max": null,+ "conditions": "maximum ambient operating temperature -20℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current at maximum ambient",+ "symbol": "IT",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 2.6,+ "max": null,+ "conditions": "maximum ambient operating temperature 0℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current at maximum ambient",+ "symbol": "IT",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 2,+ "max": null,+ "conditions": "maximum ambient operating temperature 25℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current at maximum ambient",+ "symbol": "IT",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 1.8,+ "max": null,+ "conditions": "maximum ambient operating temperature 40℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current at maximum ambient",+ "symbol": "IT",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 1.6,+ "max": null,+ "conditions": "maximum ambient operating temperature 50℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current at maximum ambient",+ "symbol": "IT",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 1.5,+ "max": null,+ "conditions": "maximum ambient operating temperature 60℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current at maximum ambient",+ "symbol": "IT",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 1.4,+ "max": null,+ "conditions": "maximum ambient operating temperature 70℃",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current at maximum ambient",+ "symbol": "IT",+ "kind": "recommended_operating",+ "unit": "A",+ "min": null,+ "typ": 1.2,+ "max": null,+ "conditions": "maximum ambient operating temperature 85℃",+ "source_page": 1,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "knsmd100"+ ],+ "discovery_pitch": "KNSMD100 (KUU) component page: datasheet pinout, KiCad symbol, footprint and 3D." }
page.json+2−4@@ -4,7 +4,7 @@ "slug": "knsmd100-16", "title": "KNSMD100/16", "brief": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",- "version": "0.1.1",+ "version": "0.1.2", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -529,12 +529,10 @@ "viewers/footprint.html", "knsmd100-hero.glb", "knsmd100-hero.overlay.json",- "knsmd100-etched.glb",- "knsmd100-etched.step", "knsmd100-16-hero.glb", "knsmd100-16-hero.overlay.json" ], "visibility": "public", "description": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "org": "adom"-}+}