← Commit history

Publish 0.1.1

Ray ·af17f42c03 · ·parent f4a72eb
4 files changed +393−14
k1206l300ar-hero.glb
⋯ 1 unchanged line ⋯
k1206l300ar-hero.overlay.json+3−3
@@ -66,14 +66,14 @@     "seating_z_mm": -0.0   },   "sources": {-    "glb": "k1206l300ar-etched.glb",-    "glb_sha256": "06167e0033c2c4b5d78fb06d9b1cadc1cf3a00b4d655a1f63a63b4aa7c571837",+    "glb": "k1206l300ar.glb",+    "glb_sha256": "a997248b57cf31da5a22aae67f8b41afc7c735349b879a46945cc2396bfcdecb",     "footprint": "k1206l300ar.kicad_mod",     "footprint_sha256": "8f4307d8c771db71526ed8ccf7c762824636660adec3635905932cc5e1d02280",     "pins": "page.json component.pins",     "pins_sha256": "f89b6cef1dd40bf094bc57ef23dc246a408922a81bfac75b8bc341584ea4e214"   },-  "generator": "adom-wiki 1.8.14 (component_hero)",+  "generator": "adom-wiki 1.8.25 (component_hero)",   "labels": [     {       "pad": "1",
package.json+384−4
@@ -1,6 +1,6 @@ {   "slug": "k1206l300ar",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",   "tags": [@@ -28,8 +28,7 @@     "viewers/symbol.html",     "viewers/footprint.html",     "k1206l300ar-hero.glb",-    "k1206l300ar-hero.overlay.json",-    "k1206l300ar-etched.glb"+    "k1206l300ar-hero.overlay.json"   ],   "component": {     "mpn": "K1206L300AR",@@ -153,5 +152,386 @@         "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"       }     ]-  }+  },+  "title": "K1206L300AR",+  "brief": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "KUU",+      "Package": "1206",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "appearance": {+      "contacts": {+        "quote": "Terminal pad materials:Tin-plated Nickel-Copper",+        "page": 3,+        "doc": "ds.pdf",+        "material": "Copper",+        "plating": "tin"+      },+      "version": 1,+      "datasheet_sha256": "721b9028d85f951da2f20f52a1c87ff75d57c8d71285fabcaa640bf6380958a8"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "721b9028d85f951da2f20f52a1c87ff75d57c8d71285fabcaa640bf6380958a8",+      "rows": [+        {+          "name": "Resistance prior to tripping, minimum (Ri min)",+          "symbol": "Ri min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.01,+          "typ": null,+          "max": null,+          "conditions": "25°C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum resistance one hour post reflow (R1max)",+          "symbol": "R1max",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 0.05,+          "conditions": "measured one hour post reflow",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum operating voltage",+          "symbol": "Vmax",+          "kind": "absolute_maximum",+          "unit": "V dc",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "at rated current (Imax)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current",+          "symbol": "Imax",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 35,+          "conditions": "at rated voltage (Vmax)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Hold current (maximum current device will not trip)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 3,+          "conditions": "25°C still air",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current (minimum current device always trips)",+          "symbol": "I trip",+          "kind": "electrical",+          "unit": "A",+          "min": 6,+          "typ": null,+          "max": null,+          "conditions": "25°C still air",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "ambient operating conditions",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "device in the tripped state",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Reflow peak temperature (Tp), Pb-free",+          "symbol": "Tp",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "Pb-free assembly profile, peak temperature",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Average ramp-up rate (Ts max to Tp)",+          "symbol": "",+          "kind": "timing",+          "unit": "°C/second",+          "min": null,+          "typ": null,+          "max": 3,+          "conditions": "Ts max to Tp, Pb-free assembly profile",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Ramp-down rate",+          "symbol": "",+          "kind": "timing",+          "unit": "°C/second",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "Pb-free assembly profile",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Time from 25°C to peak temperature",+          "symbol": "",+          "kind": "timing",+          "unit": "minutes",+          "min": null,+          "typ": null,+          "max": 8,+          "conditions": "25°C to peak temperature",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Preheat temperature (Ts min to Ts max)",+          "symbol": "Ts",+          "kind": "thermal",+          "unit": "°C",+          "min": 150,+          "typ": null,+          "max": 200,+          "conditions": "preheat, Ts min to Ts max",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Preheat time (Ts min to Ts max)",+          "symbol": "ts",+          "kind": "timing",+          "unit": "s",+          "min": 60,+          "typ": null,+          "max": 180,+          "conditions": "preheat, Ts min to Ts max",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Time maintained above TL",+          "symbol": "tL",+          "kind": "timing",+          "unit": "s",+          "min": 60,+          "typ": null,+          "max": 150,+          "conditions": "time maintained above TL 217°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Time within profile peak window (TP)",+          "symbol": "tP",+          "kind": "timing",+          "unit": "s",+          "min": 20,+          "typ": null,+          "max": 40,+          "conditions": "TP as printed in profile",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 0,+          "typ": null,+          "max": 30,+          "conditions": "storage condition",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage relative humidity",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "%RH",+          "min": 30,+          "typ": null,+          "max": 60,+          "conditions": "storage condition",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Time-to-trip test (trip after 8.00 A)",+          "symbol": "",+          "kind": "timing",+          "unit": "s",+          "min": null,+          "typ": 4,+          "max": null,+          "conditions": "at 8.00 A time-to-trip test current",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Power dissipation in tripped state",+          "symbol": "Pd",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 1,+          "max": null,+          "conditions": "tripped state, 25°C still air, at rated voltage",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient temperature",+          "symbol": "I HOLD",+          "kind": "temperature_coefficient",+          "unit": "A",+          "min": null,+          "typ": 4.05,+          "max": null,+          "conditions": "ambient -40°C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient temperature",+          "symbol": "I HOLD",+          "kind": "temperature_coefficient",+          "unit": "A",+          "min": null,+          "typ": 3.66,+          "max": null,+          "conditions": "ambient -20°C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient temperature",+          "symbol": "I HOLD",+          "kind": "temperature_coefficient",+          "unit": "A",+          "min": null,+          "typ": 3.36,+          "max": null,+          "conditions": "ambient 0°C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient temperature",+          "symbol": "I HOLD",+          "kind": "temperature_coefficient",+          "unit": "A",+          "min": null,+          "typ": 3,+          "max": null,+          "conditions": "ambient 25°C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient temperature",+          "symbol": "I HOLD",+          "kind": "temperature_coefficient",+          "unit": "A",+          "min": null,+          "typ": 2.5,+          "max": null,+          "conditions": "ambient 40°C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient temperature",+          "symbol": "I HOLD",+          "kind": "temperature_coefficient",+          "unit": "A",+          "min": null,+          "typ": 2.28,+          "max": null,+          "conditions": "ambient 50°C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient temperature",+          "symbol": "I HOLD",+          "kind": "temperature_coefficient",+          "unit": "A",+          "min": null,+          "typ": 2,+          "max": null,+          "conditions": "ambient 60°C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient temperature",+          "symbol": "I HOLD",+          "kind": "temperature_coefficient",+          "unit": "A",+          "min": null,+          "typ": 1.62,+          "max": null,+          "conditions": "ambient 70°C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Recommended hold current at ambient temperature",+          "symbol": "I HOLD",+          "kind": "temperature_coefficient",+          "unit": "A",+          "min": null,+          "typ": 1.35,+          "max": null,+          "conditions": "ambient 85°C",+          "source_page": 1,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "k1206l300ar"+  ],+  "discovery_pitch": "K1206L300AR (KUU) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+6−7
@@ -4,7 +4,7 @@   "slug": "k1206l300ar",   "title": "K1206L300AR",   "brief": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -543,10 +543,9 @@     "viewers/symbol.html",     "viewers/footprint.html",     "k1206l300ar-hero.glb",-    "k1206l300ar-hero.overlay.json",-    "k1206l300ar-etched.glb"+    "k1206l300ar-hero.overlay.json"   ],-  "visibility": {-    "public": true-  }-}+  "visibility": "public",+  "description": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "org": "adom"+}\ No newline at end of file