k1206l300ar-hero.glb⋯ 1 unchanged line ⋯
k1206l300ar-hero.overlay.json+3−3@@ -66,14 +66,14 @@ "seating_z_mm": -0.0 }, "sources": {- "glb": "k1206l300ar-etched.glb",- "glb_sha256": "06167e0033c2c4b5d78fb06d9b1cadc1cf3a00b4d655a1f63a63b4aa7c571837",+ "glb": "k1206l300ar.glb",+ "glb_sha256": "a997248b57cf31da5a22aae67f8b41afc7c735349b879a46945cc2396bfcdecb", "footprint": "k1206l300ar.kicad_mod", "footprint_sha256": "8f4307d8c771db71526ed8ccf7c762824636660adec3635905932cc5e1d02280", "pins": "page.json component.pins", "pins_sha256": "f89b6cef1dd40bf094bc57ef23dc246a408922a81bfac75b8bc341584ea4e214" },- "generator": "adom-wiki 1.8.14 (component_hero)",+ "generator": "adom-wiki 1.8.25 (component_hero)", "labels": [ { "pad": "1",
package.json+384−4@@ -1,6 +1,6 @@ { "slug": "k1206l300ar",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "tags": [@@ -28,8 +28,7 @@ "viewers/symbol.html", "viewers/footprint.html", "k1206l300ar-hero.glb",- "k1206l300ar-hero.overlay.json",- "k1206l300ar-etched.glb"+ "k1206l300ar-hero.overlay.json" ], "component": { "mpn": "K1206L300AR",@@ -153,5 +152,386 @@ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" } ]- }+ },+ "title": "K1206L300AR",+ "brief": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "KUU",+ "Package": "1206",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "appearance": {+ "contacts": {+ "quote": "Terminal pad materials:Tin-plated Nickel-Copper",+ "page": 3,+ "doc": "ds.pdf",+ "material": "Copper",+ "plating": "tin"+ },+ "version": 1,+ "datasheet_sha256": "721b9028d85f951da2f20f52a1c87ff75d57c8d71285fabcaa640bf6380958a8"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "721b9028d85f951da2f20f52a1c87ff75d57c8d71285fabcaa640bf6380958a8",+ "rows": [+ {+ "name": "Resistance prior to tripping, minimum (Ri min)",+ "symbol": "Ri min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 0.01,+ "typ": null,+ "max": null,+ "conditions": "25°C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance one hour post reflow (R1max)",+ "symbol": "R1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 0.05,+ "conditions": "measured one hour post reflow",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum operating voltage",+ "symbol": "Vmax",+ "kind": "absolute_maximum",+ "unit": "V dc",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "at rated current (Imax)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current",+ "symbol": "Imax",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 35,+ "conditions": "at rated voltage (Vmax)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current (maximum current device will not trip)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 3,+ "conditions": "25°C still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current (minimum current device always trips)",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 6,+ "typ": null,+ "max": null,+ "conditions": "25°C still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "ambient operating conditions",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "device in the tripped state",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Reflow peak temperature (Tp), Pb-free",+ "symbol": "Tp",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "Pb-free assembly profile, peak temperature",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Average ramp-up rate (Ts max to Tp)",+ "symbol": "",+ "kind": "timing",+ "unit": "°C/second",+ "min": null,+ "typ": null,+ "max": 3,+ "conditions": "Ts max to Tp, Pb-free assembly profile",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Ramp-down rate",+ "symbol": "",+ "kind": "timing",+ "unit": "°C/second",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "Pb-free assembly profile",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Time from 25°C to peak temperature",+ "symbol": "",+ "kind": "timing",+ "unit": "minutes",+ "min": null,+ "typ": null,+ "max": 8,+ "conditions": "25°C to peak temperature",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Preheat temperature (Ts min to Ts max)",+ "symbol": "Ts",+ "kind": "thermal",+ "unit": "°C",+ "min": 150,+ "typ": null,+ "max": 200,+ "conditions": "preheat, Ts min to Ts max",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Preheat time (Ts min to Ts max)",+ "symbol": "ts",+ "kind": "timing",+ "unit": "s",+ "min": 60,+ "typ": null,+ "max": 180,+ "conditions": "preheat, Ts min to Ts max",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Time maintained above TL",+ "symbol": "tL",+ "kind": "timing",+ "unit": "s",+ "min": 60,+ "typ": null,+ "max": 150,+ "conditions": "time maintained above TL 217°C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Time within profile peak window (TP)",+ "symbol": "tP",+ "kind": "timing",+ "unit": "s",+ "min": 20,+ "typ": null,+ "max": 40,+ "conditions": "TP as printed in profile",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "storage condition",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Storage relative humidity",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "%RH",+ "min": 30,+ "typ": null,+ "max": 60,+ "conditions": "storage condition",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Time-to-trip test (trip after 8.00 A)",+ "symbol": "",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": 4,+ "max": null,+ "conditions": "at 8.00 A time-to-trip test current",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Power dissipation in tripped state",+ "symbol": "Pd",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 1,+ "max": null,+ "conditions": "tripped state, 25°C still air, at rated voltage",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Recommended hold current at ambient temperature",+ "symbol": "I HOLD",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 4.05,+ "max": null,+ "conditions": "ambient -40°C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Recommended hold current at ambient temperature",+ "symbol": "I HOLD",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 3.66,+ "max": null,+ "conditions": "ambient -20°C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Recommended hold current at ambient temperature",+ "symbol": "I HOLD",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 3.36,+ "max": null,+ "conditions": "ambient 0°C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Recommended hold current at ambient temperature",+ "symbol": "I HOLD",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 3,+ "max": null,+ "conditions": "ambient 25°C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Recommended hold current at ambient temperature",+ "symbol": "I HOLD",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 2.5,+ "max": null,+ "conditions": "ambient 40°C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Recommended hold current at ambient temperature",+ "symbol": "I HOLD",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 2.28,+ "max": null,+ "conditions": "ambient 50°C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Recommended hold current at ambient temperature",+ "symbol": "I HOLD",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 2,+ "max": null,+ "conditions": "ambient 60°C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Recommended hold current at ambient temperature",+ "symbol": "I HOLD",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 1.62,+ "max": null,+ "conditions": "ambient 70°C",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Recommended hold current at ambient temperature",+ "symbol": "I HOLD",+ "kind": "temperature_coefficient",+ "unit": "A",+ "min": null,+ "typ": 1.35,+ "max": null,+ "conditions": "ambient 85°C",+ "source_page": 1,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "k1206l300ar"+ ],+ "discovery_pitch": "K1206L300AR (KUU) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+6−7@@ -4,7 +4,7 @@ "slug": "k1206l300ar", "title": "K1206L300AR", "brief": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -543,10 +543,9 @@ "viewers/symbol.html", "viewers/footprint.html", "k1206l300ar-hero.glb",- "k1206l300ar-hero.overlay.json",- "k1206l300ar-etched.glb"+ "k1206l300ar-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "org": "adom"+}