← Commit history

Publish 0.1.2

Ray ·4b09f5e72d · ·parent d193b52
4 files changed +244−11
k1206l075-16ar-hero.glb
⋯ 1 unchanged line ⋯
k1206l075-16ar-hero.overlay.json+3−3
@@ -66,14 +66,14 @@     "seating_z_mm": -0.0   },   "sources": {-    "glb": "k1206l075-etched.glb",-    "glb_sha256": "c5c841cb78bff67800b33b7a2a47ec0b9e1597d731729940ee5153802ad4d1f8",+    "glb": "k1206l075.glb",+    "glb_sha256": "a997248b57cf31da5a22aae67f8b41afc7c735349b879a46945cc2396bfcdecb",     "footprint": "k1206l075.kicad_mod",     "footprint_sha256": "8f4307d8c771db71526ed8ccf7c762824636660adec3635905932cc5e1d02280",     "pins": "page.json component.pins",     "pins_sha256": "f89b6cef1dd40bf094bc57ef23dc246a408922a81bfac75b8bc341584ea4e214"   },-  "generator": "adom-wiki 1.8.22 (component_hero)",+  "generator": "adom-wiki 1.8.25 (component_hero)",   "labels": [     {       "pad": "1",
package.json+239−4
@@ -1,6 +1,6 @@ {   "slug": "k1206l075-16ar",-  "version": "0.1.1",+  "version": "0.1.2",   "type": "component",   "description": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",   "tags": [@@ -29,8 +29,6 @@     "viewers/footprint.html",     "k1206l075-hero.glb",     "k1206l075-hero.overlay.json",-    "k1206l075-etched.glb",-    "k1206l075-etched.step",     "k1206l075-16ar-hero.glb",     "k1206l075-16ar-hero.overlay.json"   ],@@ -165,5 +163,242 @@       "note": "renamed from the cut-base slug to the part it was built from (slug collision split, 2026-11-11)"     }   },-  "visibility": "public"+  "visibility": "public",+  "title": "K1206L075/16AR",+  "brief": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "KUU",+      "Package": "1206",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "e4322a87beb1bfb119cae4952326f26065f68b971de7f06d524bcaa77bfbca4c",+      "rows": [+        {+          "name": "Maximum operating voltage",+          "symbol": "Vmax",+          "kind": "electrical",+          "unit": "V dc",+          "min": null,+          "typ": null,+          "max": 16,+          "conditions": "at rated current (Imax)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current",+          "symbol": "Imax",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 35,+          "conditions": "at rated voltage (Vmax)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Hold current",+          "symbol": "Ihold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.75,+          "conditions": "25°C still air; maximum current device will not trip",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current",+          "symbol": "Itrip",+          "kind": "electrical",+          "unit": "A",+          "min": 1.5,+          "typ": null,+          "max": null,+          "conditions": "25°C still air; minimum current at which device always trips",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Power dissipation in tripped state",+          "symbol": "Pd",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.6,+          "max": null,+          "conditions": "tripped state, 25°C still air, at rated voltage",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Minimum resistance prior to tripping",+          "symbol": "Ri min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.09,+          "typ": null,+          "max": null,+          "conditions": "25°C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum resistance one hour post reflow",+          "symbol": "R1max",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "measured one hour post reflow, 25°C",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Passive aging resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85°C, 1000 hrs; typical",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Humidity aging resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85°C, 85% R.H., 168 hours; typical",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Thermal shock resistance change",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -33,+          "typ": null,+          "max": 33,+          "conditions": "+85°C to -40°C, 20 times; typical",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "ambient operating conditions",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "device in tripped state",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 0,+          "typ": null,+          "max": 35,+          "conditions": "storage condition",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage relative humidity",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "%RH",+          "min": 30,+          "typ": null,+          "max": 60,+          "conditions": "storage condition",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Peak reflow temperature",+          "symbol": "Tp",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "Pb-free reflow profile; exceeding recommended profile may void performance",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Average ramp-up rate (Ts max to Tp)",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C/second",+          "min": null,+          "typ": null,+          "max": 3,+          "conditions": "Pb-free reflow profile",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Ramp-down rate",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C/second",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "Pb-free reflow profile",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Time from 25°C to peak temperature",+          "symbol": "",+          "kind": "thermal",+          "unit": "minutes",+          "min": null,+          "typ": null,+          "max": 8,+          "conditions": "Pb-free reflow profile",+          "source_page": 2,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "k1206l075"+  ],+  "discovery_pitch": "K1206L075 (KUU) component page: datasheet pinout, KiCad symbol, footprint and 3D." }
page.json+2−4
@@ -4,7 +4,7 @@   "slug": "k1206l075-16ar",   "title": "K1206L075/16AR",   "brief": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",-  "version": "0.1.1",+  "version": "0.1.2",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -409,12 +409,10 @@     "viewers/footprint.html",     "k1206l075-hero.glb",     "k1206l075-hero.overlay.json",-    "k1206l075-etched.glb",-    "k1206l075-etched.step",     "k1206l075-16ar-hero.glb",     "k1206l075-16ar-hero.overlay.json"   ],   "visibility": "public",   "description": "KUU Resettable Fuses, 1206. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",   "org": "adom"-}+}\ No newline at end of file