← Commit history

Set visibility: public

Ray ·627ae940b6 · ·parent 11fd263
1 file changed +7−4
page.json+7−4
@@ -44,7 +44,7 @@         "number": "3",         "name": "RXD",         "type": "output",-        "description": "CAN receive data output to the MCU. LOW indicates a dominant bus state, HIGH indicates a recessive bus state. Output current limited to \u00b115 mA (absolute max)."+        "description": "CAN receive data output to the MCU. LOW indicates a dominant bus state, HIGH indicates a recessive bus state. Output current limited to ±15 mA (absolute max)."       },       {         "number": "4",@@ -62,13 +62,13 @@         "number": "6",         "name": "CANL",         "type": "bidirectional",-        "description": "Low-level CAN bus line. Withstands \u00b170 V DC bus fault, \u00b130 V common-mode range, and \u00b116 kV HBM ESD (to GND2). High-impedance when unpowered."+        "description": "Low-level CAN bus line. Withstands ±70 V DC bus fault, ±30 V common-mode range, and ±16 kV HBM ESD (to GND2). High-impedance when unpowered."       },       {         "number": "7",         "name": "CANH",         "type": "bidirectional",-        "description": "High-level CAN bus line. Withstands \u00b170 V DC bus fault, \u00b130 V common-mode range, and \u00b116 kV HBM ESD (to GND2). High-impedance when unpowered."+        "description": "High-level CAN bus line. Withstands ±70 V DC bus fault, ±30 V common-mode range, and ±16 kV HBM ESD (to GND2). High-impedance when unpowered."       },       {         "number": "8",@@ -138,5 +138,8 @@     "docs/iso1042bdwvr-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file