← Commit history
page.json+7−4@@ -44,7 +44,7 @@ "number": "3", "name": "RXD", "type": "output",- "description": "CAN receive data output to the MCU. LOW indicates a dominant bus state, HIGH indicates a recessive bus state. Output current limited to \u00b115 mA (absolute max)."+ "description": "CAN receive data output to the MCU. LOW indicates a dominant bus state, HIGH indicates a recessive bus state. Output current limited to ±15 mA (absolute max)." }, { "number": "4",@@ -62,13 +62,13 @@ "number": "6", "name": "CANL", "type": "bidirectional",- "description": "Low-level CAN bus line. Withstands \u00b170 V DC bus fault, \u00b130 V common-mode range, and \u00b116 kV HBM ESD (to GND2). High-impedance when unpowered."+ "description": "Low-level CAN bus line. Withstands ±70 V DC bus fault, ±30 V common-mode range, and ±16 kV HBM ESD (to GND2). High-impedance when unpowered." }, { "number": "7", "name": "CANH", "type": "bidirectional",- "description": "High-level CAN bus line. Withstands \u00b170 V DC bus fault, \u00b130 V common-mode range, and \u00b116 kV HBM ESD (to GND2). High-impedance when unpowered."+ "description": "High-level CAN bus line. Withstands ±70 V DC bus fault, ±30 V common-mode range, and ±16 kV HBM ESD (to GND2). High-impedance when unpowered." }, { "number": "8",@@ -138,5 +138,8 @@ "docs/iso1042bdwvr-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }