← Commit history

irlml0060trpbf: specified limits as data (metadata.characteristics, 37 rows from the datasheet)

Ray ·c8b9048315 ·17d ago ·parent 5bc36cf
2 files changed +496−1
README.md+44
@@ -21,6 +21,50 @@ IRLML0060TRPBF from Infineon Technologies, in a SOT-23. Pinout and pin descripti | Category | Transistors/Thyristors | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Drain-Source Voltage | VDS |  |  | 60 | V |  | 1 |+| Continuous Drain Current, TA = 25°C | ID @ TA = 25°C |  |  | 2.7 | A | VGS @ 10V | 1 |+| Continuous Drain Current, TA = 70°C | ID @ TA = 70°C |  |  | 2.1 | A | VGS @ 10V | 1 |+| Pulsed Drain Current | IDM |  |  | 11 | A |  | 1 |+| Maximum Power Dissipation, TA = 25°C | PD @TA = 25°C |  |  | 1.25 | W |  | 1 |+| Maximum Power Dissipation, TA = 70°C | PD @TA = 70°C |  |  | 0.8 | W |  | 1 |+| Linear Derating Factor |  |  |  | 0.01 | W/°C |  | 1 |+| Gate-to-Source Voltage | VGS | -16 |  | 16 | V |  | 1 |+| Junction and Storage Temperature Range | TJ, TSTG | -55 |  | 150 | °C |  | 1 |+| Junction-to-Ambient | RJA |  |  | 100 | °C/W |  | 1 |+| Junction-to-Ambient (t<10s) | RJA |  |  | 99 | °C/W | t<10s | 1 |+| Drain-to-Source Breakdown Voltage | V(BR)DSS | 60 |  |  | V | VGS = 0V, ID = 250μA | 2 |+| Static Drain-to-Source On-Resistance | RDS(on) |  | 98 | 116 | mΩ | VGS = 4.5V, ID = 2.2A | 2 |+| Static Drain-to-Source On-Resistance | RDS(on) |  | 78 | 92 | mΩ | VGS = 10V, ID = 2.7A | 2 |+| Gate Threshold Voltage | VGS(th) | 1 |  | 2.5 | V | VDS = VGS, ID = 25μA | 2 |+| Drain-to-Source Leakage Current | IDSS |  |  | 20 | μA | VDS = 60V, VGS = 0V | 2 |+| Drain-to-Source Leakage Current, TJ = 125°C | IDSS |  |  | 250 | μA | VDS = 60V, VGS = 0V, TJ = 125°C | 2 |+| Gate-to-Source Forward Leakage | IGSS |  |  | 100 | nA | VGS = 20V | 2 |+| Gate-to-Source Reverse Leakage |  |  |  | -100 | nA | VGS = -20V | 2 |+| Forward Transconductance | gfs | 7.6 |  |  | S | VDS = 25V, ID = 2.7A | 2 |+| Reverse Recovery Time | trr |  | 14 | 21 | ns | TJ = 25°C, VR = 30V, IF=1.6A | 2 |+| Reverse Recovery Charge | Qrr |  | 13 | 20 | nC | TJ = 25°C, VR = 30V, IF=1.6A | 2 |+| Diode Forward Voltage | VSD |  |  | 1.3 | V | TJ = 25°C, IS = 2.7A, VGS = 0V | 2 |+| Continuous Source Current (Body Diode) | IS |  |  | 1.6 | A |  | 2 |+| Pulsed Source Current (Body Diode) | ISM |  |  | 11 | A |  | 2 |+| Breakdown Voltage Temp. Coefficient | V(BR)DSS/TJ |  | 0.06 |  | V/°C | Reference to 25°C, ID = 1mA | 2 |+| Internal Gate Resistance | RG |  | 1.6 |  |  |  | 2 |+| Total Gate Charge | Qg |  | 2.5 |  | nC |  | 2 |+| Gate-to-Source Charge | Qgs |  | 0.7 |  | nC |  | 2 |+| Gate-to-Drain (Miller) Charge | Qgd |  | 1.3 |  | nC |  | 2 |+| Turn-On Delay Time | td(on) |  | 5.4 |  | ns |  | 2 |+| Rise Time | tr |  | 6.3 |  | ns |  | 2 |+| Turn-Off Delay Time | td(off) |  | 6.8 |  | ns |  | 2 |+| Fall Time | tf |  | 4.2 |  | ns |  | 2 |+| Input Capacitance | Ciss |  | 290 |  | pF |  | 2 |+| Output Capacitance | Coss |  | 37 |  | pF |  | 2 |+| Reverse Transfer Capacitance | Crss |  | 21 |  | pF |  | 2 |+ ## CAD (KiCad official)  - Symbol: `IRLML0060TRPBF`
page.json+452−1
@@ -151,6 +151,457 @@       "Package": "SOT-23",       "Category": "Transistors/Thyristors",       "Pins": "3"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "1ae7289b2b3c500f",+      "rows": [+        {+          "name": "Drain-Source Voltage",+          "symbol": "VDS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 60,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous Drain Current, TA = 25°C",+          "symbol": "ID @ TA = 25°C",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 2.7,+          "conditions": "VGS @ 10V",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Continuous Drain Current, TA = 70°C",+          "symbol": "ID @ TA = 70°C",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 2.1,+          "conditions": "VGS @ 10V",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Pulsed Drain Current",+          "symbol": "IDM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 11,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum Power Dissipation, TA = 25°C",+          "symbol": "PD @TA = 25°C",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 1.25,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum Power Dissipation, TA = 70°C",+          "symbol": "PD @TA = 70°C",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 0.8,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Linear Derating Factor",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "W/°C",+          "min": null,+          "typ": null,+          "max": 0.01,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Gate-to-Source Voltage",+          "symbol": "VGS",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -16,+          "typ": null,+          "max": 16,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Junction and Storage Temperature Range",+          "symbol": "TJ, TSTG",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-Ambient",+          "symbol": "RJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 100,+          "conditions": "",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Junction-to-Ambient (t<10s)",+          "symbol": "RJA",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 99,+          "conditions": "t<10s",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Drain-to-Source Breakdown Voltage",+          "symbol": "V(BR)DSS",+          "kind": "electrical",+          "unit": "V",+          "min": 60,+          "typ": null,+          "max": null,+          "conditions": "VGS = 0V, ID = 250μA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Static Drain-to-Source On-Resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": 98,+          "max": 116,+          "conditions": "VGS = 4.5V, ID = 2.2A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Static Drain-to-Source On-Resistance",+          "symbol": "RDS(on)",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": 78,+          "max": 92,+          "conditions": "VGS = 10V, ID = 2.7A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate Threshold Voltage",+          "symbol": "VGS(th)",+          "kind": "electrical",+          "unit": "V",+          "min": 1,+          "typ": null,+          "max": 2.5,+          "conditions": "VDS = VGS, ID = 25μA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-to-Source Leakage Current",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "VDS = 60V, VGS = 0V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Drain-to-Source Leakage Current, TJ = 125°C",+          "symbol": "IDSS",+          "kind": "electrical",+          "unit": "μA",+          "min": null,+          "typ": null,+          "max": 250,+          "conditions": "VDS = 60V, VGS = 0V, TJ = 125°C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-to-Source Forward Leakage",+          "symbol": "IGSS",+          "kind": "electrical",+          "unit": "nA",+          "min": null,+          "typ": null,+          "max": 100,+          "conditions": "VGS = 20V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-to-Source Reverse Leakage",+          "symbol": "",+          "kind": "electrical",+          "unit": "nA",+          "min": null,+          "typ": null,+          "max": -100,+          "conditions": "VGS = -20V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Forward Transconductance",+          "symbol": "gfs",+          "kind": "electrical",+          "unit": "S",+          "min": 7.6,+          "typ": null,+          "max": null,+          "conditions": "VDS = 25V, ID = 2.7A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reverse Recovery Time",+          "symbol": "trr",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 14,+          "max": 21,+          "conditions": "TJ = 25°C, VR = 30V, IF=1.6A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reverse Recovery Charge",+          "symbol": "Qrr",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 13,+          "max": 20,+          "conditions": "TJ = 25°C, VR = 30V, IF=1.6A",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Diode Forward Voltage",+          "symbol": "VSD",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.3,+          "conditions": "TJ = 25°C, IS = 2.7A, VGS = 0V",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Continuous Source Current (Body Diode)",+          "symbol": "IS",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 1.6,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Pulsed Source Current (Body Diode)",+          "symbol": "ISM",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 11,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Breakdown Voltage Temp. Coefficient",+          "symbol": "V(BR)DSS/TJ",+          "kind": "temperature_coefficient",+          "unit": "V/°C",+          "min": null,+          "typ": 0.06,+          "max": null,+          "conditions": "Reference to 25°C, ID = 1mA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Internal Gate Resistance",+          "symbol": "RG",+          "kind": "electrical",+          "unit": "",+          "min": null,+          "typ": 1.6,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Total Gate Charge",+          "symbol": "Qg",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 2.5,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-to-Source Charge",+          "symbol": "Qgs",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 0.7,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-to-Drain (Miller) Charge",+          "symbol": "Qgd",+          "kind": "electrical",+          "unit": "nC",+          "min": null,+          "typ": 1.3,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-On Delay Time",+          "symbol": "td(on)",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 5.4,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Rise Time",+          "symbol": "tr",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 6.3,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-Off Delay Time",+          "symbol": "td(off)",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 6.8,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Fall Time",+          "symbol": "tf",+          "kind": "electrical",+          "unit": "ns",+          "min": null,+          "typ": 4.2,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Input Capacitance",+          "symbol": "Ciss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 290,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Output Capacitance",+          "symbol": "Coss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 37,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reverse Transfer Capacitance",+          "symbol": "Crss",+          "kind": "electrical",+          "unit": "pF",+          "min": null,+          "typ": 21,+          "max": null,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -192,4 +643,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}