page.json+6−3@@ -38,13 +38,13 @@ "number": "2", "name": "RESET", "type": "output",- "description": "Active-low reset output. Asserted low when VCC drops below the 3.08 V (\u00b12.5%) detection threshold; held low for typ. 500 ms (Trp) after VCC recovers. VOL \u2264 0.3 V @ ISINK=1.2 mA; VOH \u2265 0.8\u00b7VCC @ ISOURCE=500 \u00b5A."+ "description": "Active-low reset output. Asserted low when VCC drops below the 3.08 V (±2.5%) detection threshold; held low for typ. 500 ms (Trp) after VCC recovers. VOL ≤ 0.3 V @ ISINK=1.2 mA; VOH ≥ 0.8·VCC @ ISOURCE=500 µA." }, { "number": "3", "name": "VCC", "type": "power_in",- "description": "Supply input and monitored voltage. Operating range 1.0 V to 6.0 V; absolute max 6.5 V. Detection threshold Vth = 3.08 V (\u00b12.5%) for the -T variant. Quiescent current 2 \u00b5A typ. (5 \u00b5A max)."+ "description": "Supply input and monitored voltage. Operating range 1.0 V to 6.0 V; absolute max 6.5 V. Detection threshold Vth = 3.08 V (±2.5%) for the -T variant. Quiescent current 2 µA typ. (5 µA max)." } ], "provenance": {@@ -108,5 +108,8 @@ "docs/imp809t-td-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }