← Commit history
page.json+6−3@@ -38,7 +38,7 @@ "number": "2", "name": "CS", "type": "input",- "description": "Overcurrent detection input and charger detection terminal. Senses the voltage drop across the series MOSFETs (M1+M2) via a 2k\u03a9 resistor for discharge-overcurrent (V_DIP=150mV), load-short-circuit (V_SIP=0.85V typ), and charge-overcurrent (V_CIP=-225mV) detection. High-voltage tolerant (absolute max V_CS = VDD-20 to VDD+0.3V, rated to 20V for charger connection)."+ "description": "Overcurrent detection input and charger detection terminal. Senses the voltage drop across the series MOSFETs (M1+M2) via a 2kΩ resistor for discharge-overcurrent (V_DIP=150mV), load-short-circuit (V_SIP=0.85V typ), and charge-overcurrent (V_CIP=-225mV) detection. High-voltage tolerant (absolute max V_CS = VDD-20 to VDD+0.3V, rated to 20V for charger connection)." }, { "number": "3",@@ -56,7 +56,7 @@ "number": "5", "name": "VDD", "type": "power_in",- "description": "Positive supply / battery positive terminal input. Connect to Li-ion cell positive through a 100\u03a9 current-limit / ESD resistor (R1) with a 0.1\u00b5F bypass cap (C1) to VSS. Operating voltage V_DSOP1 = 1.5V to 8V (abs max VSS-0.3 to VSS+10V). Typical operating current I_DD = 3.0\u00b5A at V_DD=3.9V."+ "description": "Positive supply / battery positive terminal input. Connect to Li-ion cell positive through a 100Ω current-limit / ESD resistor (R1) with a 0.1µF bypass cap (C1) to VSS. Operating voltage V_DSOP1 = 1.5V to 8V (abs max VSS-0.3 to VSS+10V). Typical operating current I_DD = 3.0µA at V_DD=3.9V." }, { "number": "6",@@ -126,5 +126,8 @@ "docs/hy2116-db6b-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }