← Commit history
page.json+6−3@@ -44,7 +44,7 @@ "number": "3", "name": "BAT", "type": "power_out",- "description": "Battery positive-terminal connection. Sources the charge current and regulates to a 4.2 V \u00b11% float voltage. In shutdown or sleep, BAT leakage is < 3 uA. Absolute max 7 V, continuous BAT current rated to 600 mA (typ. 500 mA charge)."+ "description": "Battery positive-terminal connection. Sources the charge current and regulates to a 4.2 V ±1% float voltage. In shutdown or sleep, BAT leakage is < 3 uA. Absolute max 7 V, continuous BAT current rated to 600 mA (typ. 500 mA charge)." }, { "number": "4",@@ -62,7 +62,7 @@ "number": "6", "name": "PROG", "type": "input",- "description": "Charge-current programming pin. A resistor RPROG from PROG to GND sets the constant-current level: IBAT = 1000 V / RPROG (e.g. 2 k\u03a9 \u2192 500 mA, 10 k\u03a9 \u2192 100 mA). Pin regulates to 1 V in CC mode and to 0.1 V during trickle charge; charging terminates when PROG falls below ~100 mV for > 2 ms (C/10 detect). Absolute max \u00b10.3 V (with respect to GND) / 600 uA."+ "description": "Charge-current programming pin. A resistor RPROG from PROG to GND sets the constant-current level: IBAT = 1000 V / RPROG (e.g. 2 kΩ → 500 mA, 10 kΩ → 100 mA). Pin regulates to 1 V in CC mode and to 0.1 V during trickle charge; charging terminates when PROG falls below ~100 mV for > 2 ms (C/10 detect). Absolute max ±0.3 V (with respect to GND) / 600 uA." } ], "provenance": {@@ -132,5 +132,8 @@ "docs/hx4057a-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }