← Commit history

Publish 0.1.1

Ray ·86e4e4377a · ·parent d1c6a6c
2 files changed +274−10
package.json+267−4
@@ -1,6 +1,6 @@ {   "slug": "ht26ls32arz",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "HTCSEMI Multi-protocol Transceivers, SOP-16. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",   "tags": [@@ -29,7 +29,8 @@     "viewers/footprint.html",     "ht26ls32arz-hero.glb",     "ht26ls32arz-hero.overlay.json",-    "ht26ls32arz-etched.glb"+    "ht26ls32arz-etched.glb",+    "ht26ls32arz-etched.step"   ],   "component": {     "mpn": "HT26LS32ARZ",@@ -43,7 +44,7 @@       "symbol": "ht26ls32arz.kicad_sym",       "footprint": "ht26ls32arz.kicad_mod",       "model_3d": "ht26ls32arz-hero.glb",-      "model_3d_plain": "ht26ls32arz-etched.glb",+      "model_3d_plain": "ht26ls32arz.glb",       "model_3d_step": "ht26ls32arz-etched.step",       "model_3d_step_plain": "ht26ls32arz.step",       "lbr": "ht26ls32arz.lbr"@@ -236,5 +237,267 @@         "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"       }     ]-  }+  },+  "title": "HT26LS32ARZ",+  "brief": "HTCSEMI Multi-protocol Transceivers, SOP-16. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "HTCSEMI",+      "Package": "SOP-16",+      "Category": "Communication Interface Chip/UART/485/232",+      "Pins": "16"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "4bc48d9beb2b50207936774cbb568f10b1acc16cce9529512bfc1a6e018b9738",+      "rows": [+        {+          "name": "Supply Range",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 7,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Voltage at Any Pin",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": null,+          "conditions": "Printed as GND-0.3V to VCC + 0.3V; upper limit is VCC + 0.3V, not a numeric value",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Storage Temperature",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "C",+          "min": -60,+          "typ": null,+          "max": 160,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Package Dissipation",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "mW",+          "min": null,+          "typ": null,+          "max": 500,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operating Temperature",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Propagation Delay, Input to Output",+          "symbol": "T1",+          "kind": "timing",+          "unit": "ns",+          "min": 8,+          "typ": null,+          "max": 10,+          "conditions": "S1=VCC",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Propagation Delay, Input to Output",+          "symbol": "T2",+          "kind": "timing",+          "unit": "ns",+          "min": 18,+          "typ": null,+          "max": 20,+          "conditions": "S1=GND",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output Enable Time",+          "symbol": "T3",+          "kind": "timing",+          "unit": "ns",+          "min": 18,+          "typ": null,+          "max": 20,+          "conditions": "VDIF=2.5V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output Disable Time",+          "symbol": "T4",+          "kind": "timing",+          "unit": "ns",+          "min": 18,+          "typ": null,+          "max": 20,+          "conditions": "VDIF=2.5V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Enable High Level",+          "symbol": "VIH",+          "kind": "electrical",+          "unit": "V",+          "min": 2,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Enable Low Level",+          "symbol": "VIL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.8,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output High Level",+          "symbol": "VOH",+          "kind": "electrical",+          "unit": "V",+          "min": 3.8,+          "typ": null,+          "max": null,+          "conditions": "IOH= -6mA",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output Low Level",+          "symbol": "VOL",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.4,+          "conditions": "IOH= 6mA",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Differential Input Level",+          "symbol": "VID",+          "kind": "electrical",+          "unit": "V",+          "min": -0.2,+          "typ": null,+          "max": 0.2,+          "conditions": "-7V < VCM < +7V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input Hysteresis",+          "symbol": "VH",+          "kind": "electrical",+          "unit": "mV",+          "min": 50,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input Current",+          "symbol": "IIN",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operating Current",+          "symbol": "ICC",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 12,+          "conditions": "VDIF=+1V",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Three-State Output Leakage",+          "symbol": "IOZ",+          "kind": "electrical",+          "unit": "µA",+          "min": 1,+          "typ": null,+          "max": 5,+          "conditions": "VOUT=VCC or GND",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Enable Input Current",+          "symbol": "IEN",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VIN=VCC or GND",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input Resistance",+          "symbol": "VR",+          "kind": "electrical",+          "unit": "KQ",+          "min": 5,+          "typ": null,+          "max": 15,+          "conditions": "-7V < VCM < +7V",+          "source_page": 3,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "ht26ls32arz"+  ],+  "discovery_pitch": "HT26LS32ARZ (HTCSEMI) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+7−6
@@ -4,7 +4,7 @@   "slug": "ht26ls32arz",   "title": "HT26LS32ARZ",   "brief": "HTCSEMI Multi-protocol Transceivers, SOP-16. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -25,7 +25,7 @@       "symbol": "ht26ls32arz.kicad_sym",       "footprint": "ht26ls32arz.kicad_mod",       "model_3d": "ht26ls32arz-hero.glb",-      "model_3d_plain": "ht26ls32arz-etched.glb",+      "model_3d_plain": "ht26ls32arz.glb",       "model_3d_step": "ht26ls32arz-etched.step",       "model_3d_step_plain": "ht26ls32arz.step",       "lbr": "ht26ls32arz.lbr"@@ -509,9 +509,10 @@     "viewers/footprint.html",     "ht26ls32arz-hero.glb",     "ht26ls32arz-hero.overlay.json",-    "ht26ls32arz-etched.glb"+    "ht26ls32arz-etched.glb",+    "ht26ls32arz-etched.step"   ],-  "visibility": {-    "public": true-  }+  "visibility": "public",+  "description": "HTCSEMI Multi-protocol Transceivers, SOP-16. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+  "org": "adom" }\ No newline at end of file