← Commit history

Set visibility: public

Ray ·b2df365eaa ·27d ago ·parent 437ba65
1 file changed +5−2
page.json+5−2
@@ -50,7 +50,7 @@         "number": "4",         "name": "VC",         "type": "input",-        "description": "Cell balance / intermediate tap sense terminal. Connects to the negative terminal of battery cell 1 and the positive terminal of battery cell 2, allowing per-cell voltage monitoring of the 2-series LiFePO4 pack. Typically connected via a 330 \u03a9 series resistor and 0.1 uF decoupling capacitor."+        "description": "Cell balance / intermediate tap sense terminal. Connects to the negative terminal of battery cell 1 and the positive terminal of battery cell 2, allowing per-cell voltage monitoring of the 2-series LiFePO4 pack. Typically connected via a 330 Ω series resistor and 0.1 uF decoupling capacitor."       },       {         "number": "5",@@ -132,5 +132,8 @@     "docs/ht2122artz-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file