← Commit history
page.json+18−15@@ -50,13 +50,13 @@ "number": "4", "name": "VMA", "type": "power_in",- "description": "A-bridge motor supply, 8V to 32V. All VM pins must be tied together and bypassed to GND (\u2265100uF bulk plus 0.1uF ceramic close to pin)."+ "description": "A-bridge motor supply, 8V to 32V. All VM pins must be tied together and bypassed to GND (≥100uF bulk plus 0.1uF ceramic close to pin)." }, { "number": "5", "name": "AOUT1", "type": "output",- "description": "A-bridge H-bridge output 1. Connects to one terminal of the stepper motor A-phase coil. Rated \u00b12.5A (positive current is defined as AOUT1 \u2192 AOUT2)."+ "description": "A-bridge H-bridge output 1. Connects to one terminal of the stepper motor A-phase coil. Rated ±2.5A (positive current is defined as AOUT1 → AOUT2)." }, { "number": "6",@@ -74,7 +74,7 @@ "number": "8", "name": "BOUT2", "type": "output",- "description": "B-bridge H-bridge output 2. Connects to one terminal of the stepper motor B-phase coil. Positive current direction is BOUT1 \u2192 BOUT2."+ "description": "B-bridge H-bridge output 2. Connects to one terminal of the stepper motor B-phase coil. Positive current direction is BOUT1 → BOUT2." }, { "number": "9",@@ -98,7 +98,7 @@ "number": "12", "name": "AVREF", "type": "input",- "description": "A-bridge current-set reference input, 1V to 3.5V (VREF absolute max -0.3 to 4V). Chopping current ICHOP = VAVREF / (5\u00b7Rs). Typically tied to BVREF and to V3P3OUT via a divider with 0.1uF bypass."+ "description": "A-bridge current-set reference input, 1V to 3.5V (VREF absolute max -0.3 to 4V). Chopping current ICHOP = VAVREF / (5·Rs). Typically tied to BVREF and to V3P3OUT via a divider with 0.1uF bypass." }, { "number": "13",@@ -122,43 +122,43 @@ "number": "16", "name": "nRESET", "type": "input",- "description": "Active-low reset input. Low resets internal logic and sets the microstep indexer to HOME while disabling H-bridges; STEP inputs are ignored. Internal 100k\u03a9 pull-down."+ "description": "Active-low reset input. Low resets internal logic and sets the microstep indexer to HOME while disabling H-bridges; STEP inputs are ignored. Internal 100kΩ pull-down." }, { "number": "17", "name": "nSLEEP", "type": "input",- "description": "Active-low sleep input. Low enters low-power sleep (H-bridges, charge pump and V3P3OUT disabled). On rising edge wait tWAKE \u2248 1ms before applying STEP. Internal 100k\u03a9 pull-down."+ "description": "Active-low sleep input. Low enters low-power sleep (H-bridges, charge pump and V3P3OUT disabled). On rising edge wait tWAKE ≈ 1ms before applying STEP. Internal 100kΩ pull-down." }, { "number": "18", "name": "nFAULT", "type": "output",- "description": "Open-drain fault output. Pulled low on overcurrent (OCP) or thermal shutdown (TSD). Requires external pull-up (e.g. 10k\u03a9 to V3P3OUT). VOL = 0.35V typ at 5mA."+ "description": "Open-drain fault output. Pulled low on overcurrent (OCP) or thermal shutdown (TSD). Requires external pull-up (e.g. 10kΩ to V3P3OUT). VOL = 0.35V typ at 5mA." }, { "number": "19", "name": "DECAY", "type": "input",- "description": "Decay-mode select. Tied low = slow-rise mixed-decay fall (~25us); left floating or high = full mixed decay. External pull-down resistor (22k-100k) trims decay time. Internal 22k\u03a9 pull-down."+ "description": "Decay-mode select. Tied low = slow-rise mixed-decay fall (~25us); left floating or high = full mixed decay. External pull-down resistor (22k-100k) trims decay time. Internal 22kΩ pull-down." }, { "number": "20", "name": "DIR", "type": "input",- "description": "Direction control input. Sets the direction advanced by the internal microstep indexer on each STEP rising edge. Internal 100k\u03a9 pull-down."+ "description": "Direction control input. Sets the direction advanced by the internal microstep indexer on each STEP rising edge. Internal 100kΩ pull-down." }, { "number": "21", "name": "nENBL", "type": "input",- "description": "Active-low output enable. Low enables the H-bridge outputs; high tri-states the outputs while the indexer continues to track STEP. Internal 100k\u03a9 pull-down."+ "description": "Active-low output enable. Low enables the H-bridge outputs; high tri-states the outputs while the indexer continues to track STEP. Internal 100kΩ pull-down." }, { "number": "22", "name": "STEP", "type": "input",- "description": "Step clock input. Rising edge advances the microstep indexer by one step. fSTEP up to 250kHz; tWH/tWL \u2265 1.9us. Internal 100k\u03a9 pull-down."+ "description": "Step clock input. Rising edge advances the microstep indexer by one step. fSTEP up to 250kHz; tWH/tWL ≥ 1.9us. Internal 100kΩ pull-down." }, { "number": "23",@@ -170,19 +170,19 @@ "number": "24", "name": "MODE0", "type": "input",- "description": "Microstep resolution select bit 0. MODE[2:0] selects full/1/2/1/4/1/8/1/16/1/32-step operation per Table 1. Internal 100k\u03a9 pull-down."+ "description": "Microstep resolution select bit 0. MODE[2:0] selects full/1/2/1/4/1/8/1/16/1/32-step operation per Table 1. Internal 100kΩ pull-down." }, { "number": "25", "name": "MODE1", "type": "input",- "description": "Microstep resolution select bit 1. See MODE0. Internal 100k\u03a9 pull-down."+ "description": "Microstep resolution select bit 1. See MODE0. Internal 100kΩ pull-down." }, { "number": "26", "name": "MODE2", "type": "input",- "description": "Microstep resolution select bit 2 (MSB). See MODE0. Internal 100k\u03a9 pull-down."+ "description": "Microstep resolution select bit 2 (MSB). See MODE0. Internal 100kΩ pull-down." }, { "number": "27",@@ -274,5 +274,8 @@ "docs/hr8825-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }