Two libraries named the same (cloud copy and PC file) make Fusion ask "Select Library" on every ADD; schematic run then exceeds its 60 s budget
We kept a list of tool issues as we worked on a project, the 772 power module (LM251772), a 4-layer board built with AI Flow on the Fusion lane, and set them aside so they wouldn't slow the build down. Now that the project is finished, we're filing them together. Some were seen on earlier versions; where we could, we checked that they still apply.
Versions: fusion-bridge 1.13.4x.
What happens: our project library existed both as a PC file (TI772_Module.lbr) and as its cloud copy with the same name. Fusion kept both in its in-use list (restarting didn't clear it), and every ADD opened a "Select Library" dialog. The bridge's schematic run blocked on those dialogs and ran past its 60 s budget.
Workaround: rename the PC file (<Name>_local.lbr).
Expected: the bridge detects two in-use libraries with the same name before an ADD batch and says so (or answers the dialog with the library the call named), instead of timing out.