app
Fusion - the Fusion 360 Bridge
Public Made by Adomby adom
Drive Autodesk Fusion 360 from the cloud via Adom Bridge: component libraries, IPC package generation, board layout, exports (STEP/Gerbers/BOM/CPL), fast APS cloud search, and parametric modeling.
← Commit history
Publish 1.13.68
5 files changed
+162−7
.insiders-stage/fusion-bridge/version.json+5−5@@ -1,14 +1,14 @@ { "manifest_version": 1, "name": "fusion360",- "version": "1.13.67",- "url": "https://wiki.adom.inc/download/adom/fusion-bridge/1.13.67/adom-bridge-fusion-v1.13.67.zip",- "sha256": "1e0c336a4b117213e43bdb4d6062f38ef830347b9a881963bae6b1e4f4e92e30",- "size": 8522397,+ "version": "1.13.68",+ "url": "https://wiki.adom.inc/download/adom/fusion-bridge/1.13.68/adom-bridge-fusion-v1.13.68.zip",+ "sha256": "7a80e3964053ac2d5da46964120c276d130264239816fc51d04b16ef1e4bcb56",+ "size": 8528805, "verbPrefixes": [ "fusion_" ], "healthEndpoint": "/status",- "released_at": "2026-11-03T20:15:06Z",+ "released_at": "2026-11-03T21:49:00Z", "tier": "insiders" }
.release-page-head+1−1@@ -1 +1 @@-2d996c4820c1da7c003e6c4d25fdac6b681c5cc2+d82b6d5a586d212012f5cdea5f50689a18e6af74
install.shpage.json+1−1@@ -152,4 +152,4 @@ "confirmed_user_skills": [ "fusion-design-efficiency" ]-}+}
tests/reports/verb-test-2026-11-03_1529.jsonadded+155@@ -0,0 +1,155 @@+{+ "date": "2026-11-03_1529",+ "target": "DESKTOP-BAR6S0F",+ "tier": "daily",+ "pass": 3,+ "fail": 15,+ "sections": {+ "gui-driving": {+ "PASS": 3,+ "FAIL": 2,+ "MANUAL": 0,+ "SKIP": 0+ },+ "routing": {+ "PASS": 0,+ "FAIL": 10,+ "MANUAL": 0,+ "SKIP": 0+ },+ "bridge-lifecycle": {+ "PASS": 0,+ "FAIL": 3,+ "MANUAL": 0,+ "SKIP": 0+ }+ },+ "results": [+ {+ "verb": "fusion_dismiss_blocking_dialogs",+ "status": "PASS",+ "why": "",+ "sec": 0.1,+ "section": "gui-driving"+ },+ {+ "verb": "fusion_routing_state",+ "status": "FAIL",+ "why": "expected success, got error=Active document is 'AiflowShared136', expected 'lane-BQ25792-copy'. code=wrong_document; model is None, not the standard board model; no pads; copper layers not named F.Cu..B.Cu; no unconnected count",+ "sec": 1.1,+ "section": "routing"+ },+ {+ "verb": "fusion_board_summary",+ "status": "FAIL",+ "why": "expected success, got error=Active document is 'AiflowShared136', expected 'lane-BQ25792-copy'. code=wrong_document; missing field 'summary'",+ "sec": 3.5,+ "section": "routing"+ },+ {+ "verb": "fusion_check_dialogs",+ "status": "PASS",+ "why": "",+ "sec": 0.1,+ "section": "gui-driving"+ },+ {+ "verb": "fusion_sch_reset_fields",+ "status": "FAIL",+ "why": "expected success, got error=Give references, or all:true code=bad_args",+ "sec": 55.5,+ "section": "routing"+ },+ {+ "verb": "fusion_sch_place_part",+ "status": "FAIL",+ "why": "expected success, got error=library is a library this design already holds (AiflowShared136) or a .lbr on th code=library_missing",+ "sec": 2.9,+ "section": "routing"+ },+ {+ "verb": "fusion_sch_swap_part",+ "status": "FAIL",+ "why": "expected success, got error=library is a library this design already holds (AiflowShared136) or a .lbr on th code=library_missing",+ "sec": 1.2,+ "section": "routing"+ },+ {+ "verb": "fusion_edit_tracks",+ "status": "FAIL",+ "why": "expected success, got error=Activate a PCB board before reading or routing it code=wrong_document",+ "sec": 2.6,+ "section": "bridge-lifecycle"+ },+ {+ "verb": "fusion_place_parts",+ "status": "FAIL",+ "why": "expected success, got error=expectDocument must match the active board name exactly code=wrong_document",+ "sec": 1.3,+ "section": "bridge-lifecycle"+ },+ {+ "verb": "fusion_set_layer_count",+ "status": "FAIL",+ "why": "expected errorCode=layers_in_use got wrong_document (error=Active document is 'AiflowShared136', expected 'lane-BQ25792)",+ "sec": 1.0,+ "section": "routing"+ },+ {+ "verb": "fusion_open_board",+ "status": "FAIL",+ "why": "expected success, got error=No filePath specified. Provide a .brd file path. code=None",+ "sec": 2.4,+ "section": "gui-driving"+ },+ {+ "verb": "fusion_open_schematic",+ "status": "FAIL",+ "why": "expected success, got error=No filePath specified. Provide a .sch file path. code=None",+ "sec": 12.8,+ "section": "gui-driving"+ },+ {+ "verb": "fusion_edit_pours",+ "status": "FAIL",+ "why": "expected success, got error=Activate a PCB board before reading or routing it code=wrong_document",+ "sec": 2.3,+ "section": "bridge-lifecycle"+ },+ {+ "verb": "fusion_route_net",+ "status": "FAIL",+ "why": "expected success, got error=Activate a PCB board before reading or routing it code=wrong_document",+ "sec": 2.6,+ "section": "routing"+ },+ {+ "verb": "fusion_apply_pours",+ "status": "FAIL",+ "why": "expected success, got error=expectDocument must match the active board name exactly code=wrong_document",+ "sec": 1.2,+ "section": "routing"+ },+ {+ "verb": "fusion_schematic_run",+ "status": "FAIL",+ "why": "expected success, got error=Activate the schematic (fusion_schematic {action:\"show\"}) before building it code=wrong_document",+ "sec": 1.2,+ "section": "routing"+ },+ {+ "verb": "fusion_change_pours",+ "status": "FAIL",+ "why": "expected success, got error=expectDocument must match the active board name exactly code=wrong_document",+ "sec": 1.1,+ "section": "routing"+ },+ {+ "verb": "focus_invariance",+ "status": "PASS",+ "why": "",+ "section": "gui-driving"+ }+ ],+ "durationSec": 92.8+}