← Commit history

Update component pins

Caleb ·e2af2b2c41 ·19d ago ·parent 4c27a04
1 file changed +67−67
page.json+67−67
@@ -45,201 +45,201 @@     "pins": [       {         "number": "1",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "2",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "3",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "4",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "5",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "6",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "7",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "8",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "9",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "10",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "11",-        "name": "GND",+        "name": "GROUND",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Ground (pads 11, 13, 20, 22, 28, 30 and the paddle, per the pad connections table). [datasheet p.1]"       },       {         "number": "12",-        "name": "RF-OUT1",+        "name": "RF OUT 1",         "type": "input",-        "description": "50Ω RF output port 1 (also acts as an input when the device is used as a combiner). Covers DC to 18 GHz with ~3.2–3.3 dB typical insertion loss above the ideal 3 dB split. [datasheet p.2]"+        "description": ""       },       {         "number": "13",-        "name": "GND",+        "name": "GROUND",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Ground (pads 11, 13, 20, 22, 28, 30 and the paddle, per the pad connections table). [datasheet p.1]"       },       {         "number": "14",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "15",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "16",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "17",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "18",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "19",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "20",-        "name": "GND",+        "name": "GROUND",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Ground (pads 11, 13, 20, 22, 28, 30 and the paddle, per the pad connections table). [datasheet p.1]"       },       {         "number": "21",-        "name": "RF-IN",+        "name": "RF IN",         "type": "input",-        "description": "50Ω RF sum/common port (input when used as a splitter, output when used as a combiner). Supports DC to 18 GHz operation. [datasheet p.2]"+        "description": ""       },       {         "number": "22",-        "name": "GND",+        "name": "GROUND",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Ground (pads 11, 13, 20, 22, 28, 30 and the paddle, per the pad connections table). [datasheet p.1]"       },       {         "number": "23",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "24",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "25",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "26",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "27",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "28",-        "name": "GND",+        "name": "GROUND",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Ground (pads 11, 13, 20, 22, 28, 30 and the paddle, per the pad connections table). [datasheet p.1]"       },       {         "number": "29",-        "name": "RF-OUT2",+        "name": "RF OUT 2",         "type": "input",-        "description": "50Ω RF output port 2 (also acts as an input when the device is used as a combiner). Covers DC to 18 GHz with ~3.2–3.3 dB typical insertion loss above the ideal 3 dB split. [datasheet p.2]"+        "description": ""       },       {         "number": "30",-        "name": "GND",+        "name": "GROUND",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Ground (pads 11, 13, 20, 22, 28, 30 and the paddle, per the pad connections table). [datasheet p.1]"       },       {         "number": "31",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "32",-        "name": "NC",+        "name": "NOT USED",         "type": "input",-        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"+        "description": "Not used; ground externally (Mini-Circuits pad connections table). [datasheet p.1]"       },       {         "number": "33",-        "name": "GND",+        "name": "GROUND",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Ground (pads 11, 13, 20, 22, 28, 30 and the paddle, per the pad connections table). [datasheet p.1]"       }     ],     "provenance": {@@ -257,7 +257,7 @@       "cad": "Footprint, symbol and 3D model as used on Adom board designs; the 3D model was extracted from the board STEP export",       "pins": {         "total": 33,-        "described": 33,+        "described": 30,         "cites_pages": true,         "refuses_to_fabricate": true       }