← Commit history

Update component pins

Caleb ·63c342ec49 ·19d ago ·parent 6609d6a
1 file changed +57−57
page.json+57−57
@@ -40,68 +40,68 @@         "url": "https://www.mouser.com/en/ProductDetail/Mini-Circuits/EP2RKU%2b?qs=7MVldsJ5Uax0d3LWrY6HOw%3D%3D"       },       "lcsc": false,-      "lcsc_note": "2026-10-08: no LCSC number on the source BOM and none found in the JLCPCB/LCSC catalogue for EP2RKU+."+      "lcsc_note": "2026-10-09: no LCSC number on the source BOM and none found in the JLCPCB/LCSC catalogue for EP2RKU+."     },     "pins": [       {         "number": "1",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "2",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "3",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "4",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "5",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "6",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "7",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "8",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "9",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "10",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "11",@@ -111,9 +111,9 @@       },       {         "number": "12",-        "name": "P1",+        "name": "RF-OUT1",         "type": "input",-        "description": ""+        "description": "50Ω RF output port 1 (also acts as an input when the device is used as a combiner). Covers DC to 18 GHz with ~3.2–3.3 dB typical insertion loss above the ideal 3 dB split. [datasheet p.2]"       },       {         "number": "13",@@ -123,39 +123,39 @@       },       {         "number": "14",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "15",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "16",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "17",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "18",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "19",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "20",@@ -165,9 +165,9 @@       },       {         "number": "21",-        "name": "S",+        "name": "RF-IN",         "type": "input",-        "description": ""+        "description": "50Ω RF sum/common port (input when used as a splitter, output when used as a combiner). Supports DC to 18 GHz operation. [datasheet p.2]"       },       {         "number": "22",@@ -177,33 +177,33 @@       },       {         "number": "23",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "24",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "25",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "26",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "27",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "28",@@ -213,9 +213,9 @@       },       {         "number": "29",-        "name": "P2",+        "name": "RF-OUT2",         "type": "input",-        "description": ""+        "description": "50Ω RF output port 2 (also acts as an input when the device is used as a combiner). Covers DC to 18 GHz with ~3.2–3.3 dB typical insertion loss above the ideal 3 dB split. [datasheet p.2]"       },       {         "number": "30",@@ -225,15 +225,15 @@       },       {         "number": "31",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "32",-        "name": "GND",+        "name": "NC",         "type": "input",-        "description": "RF/DC ground. Connect to the PCB ground plane with low-inductance via stitching. [datasheet p.2]"+        "description": "Not used — must be grounded externally per datasheet. [datasheet p.2]"       },       {         "number": "33",@@ -246,7 +246,7 @@       "factory_chain": {         "pipeline": "adom-parts (board-derived) 0.1",         "pins": "KiCad symbol from the source board + adom-ds2sf datasheet extraction (claude-opus-4-7)",-        "at": "2026-10-08"+        "at": "2026-10-09"       },       "datasheet": {         "url": "https://www.minicircuits.com/pdfs/EP2RKU+.pdf",@@ -257,7 +257,7 @@       "cad": "Footprint, symbol and 3D model as used on Adom board designs; the 3D model was extracted from the board STEP export",       "pins": {         "total": 33,-        "described": 30,+        "described": 33,         "cites_pages": true,         "refuses_to_fabricate": true       }@@ -278,7 +278,7 @@         "zmin_mm": -0.0,         "footprint_binding": "identity",         "sha256": "ef2f84f5f6c9456d8b3b96cd6c539dbd0ad65820499aa1126da34555761d4ed6",-        "checked": "2026-10-08",+        "checked": "2026-10-09",         "checked_by": "adom-parts/partstep.py (placement inverse from the source board; centroid-matched to KiCad library models on 59 reference cases)"       },       {@@ -296,7 +296,7 @@         "zmin_mm": -0.0,         "footprint_binding": "identity",         "sha256": "cdf52f7847f806a5c94e13c47d78543436838027f176386f6f506eede498438f",-        "checked": "2026-10-08",+        "checked": "2026-10-09",         "checked_by": "adom-parts/partstep.py (placement inverse from the source board; centroid-matched to KiCad library models on 59 reference cases)"       }     ]