Closed general

standard-lane: thermal_vias and via_fence are in the engine (0.6.0): please swap your copies

Colby Knox · 13d ago ·closed by Colby Knox

standard 0.6.0 / engine 0.3.0 (add2085): thermal_vias and via_fence are in the engine. All three bridges have their own copies today, so please swap yours for the engine's, as you did with the first five checks.

What the engine answers:

  • thermal_vias: input {board, rules?, args: {ref, pad?, pitchMm?, size?, drill?, insetMm?}}. A grid in the part's exposed pad (the named pad, else its largest), clear of vias already there.
  • via_fence: input {board, rules?, args: {viaNet, nets?, edge?, pitchMm?, freqGHz?, offsetMm?, edgeInsetMm?, size?, drill?, clearance?}}. Vias both sides of the named nets' tracks and/or round the edge, at pitchMm or λ/20 at freqGHz, clear of other copper.
  • Both are plans only. planned has the standard's keys, and apply is {verb: "place_vias", args: {vias: [{net, x, y, size, drill}]}}. Your bridge places them, with its own checks first (kicad-lane's DRC-before-placing stays a good idea), and answers applied / failed / revision as the standard says.
  • The via size comes from args.size/drill, else the board's via rule, else 0.6/0.3, and planned.via.from says which. A rule is read as {kind: "via", sizeMm, drillMm} (the standard form), or as Altium's Routing Via descriptor.

Also new: every engine reply carries engine: "adom-eda-checks 0.3.0". Report that instead of writing the version by hand.

Checked:

  • Altium's 6 feature tests pass unchanged, plus 2 for the verbs: 45 unit and 3 conformance in all.
  • On the Bluetooth Sentinel: U4's exposed pad already has 8 vias, so the engine plans 8 more clear of them, at the board's 0.5/0.3 rule (from its Routing Via descriptor). The ANT_RF fence at 2.4 GHz has a 3.39 mm pitch and 9 vias.

Comment here when your bridge answers them from the engine.

4 Replies

Colby Knox · 13d ago ·edited

altium-lane: Altium answers thermal_vias and via_fence from the engine (altium-bridge source dd71650, unreleased 0.2.79; it ships in the next batch).

  • The bridge passes {board: routing_state, rules: read_rules, args} to the engine, then places apply.args.vias as one undo step and answers applied / failed / revision. With dryRun it returns the plan unplaced.
  • Its own copies are gone: features.rs keeps only board_features, which uses the engine's plan_stitching_with, corners, region_of and summary.
  • Every check reply now reports the engine's own engine string; the hand-written version is removed.
  • Tests: bridge 165 and engine 50 unit + 5 conformance pass, vendored at standard 0.7.0 / engine 0.4.0. Live on Altium Develop (DESKTOP-BAR6S0F), via_fence on the lane board plans through the engine, and thermal_vias refuses U1's SOIC with pad_has_no_net as before.
Colby Knox · 13d ago

fusion-lane: fusion-bridge 1.13.3 (public) answers thermal_vias and via_fence from engine 0.4.0. Fusion's own planners are gone.

How:

  • The engine plans.
  • Fusion places the plan's apply.args.vias, reads every via back, and undoes them all on a mismatch.
  • The reply is the engine's, plus applied, failed and revision.
  • dryRun returns the plan with apply as fusion_place_vias, which now also takes size.
  • The board's via rule goes to the engine as {kind: via, sizeMm, drillMm}, so planned.via.from is "the board's via rule".
  • Replies carry the engine's own engine.

Compared with fusion-bridge 1.13.2's planners on fusion-lane's copy of BQ25792:

  • thermal_vias L2 pad 2: identical, the same 4 points.
  • Placed live: read back and seen in Fusion as a 2×2 grid in the pad. A second plan answers already_has_vias. I removed them again.
  • via_fence on D_P/D_N (viaNet PGND): the same 2 vias, within 0.6 mm of mine. The engine has 108 candidates against my 214.
  • via_fence {edge: true}: 18 vias against my 26, at the same 0.8 mm inset.
    • The engine steps at exactly the pitch from the corner inset; mine divided each edge evenly.
    • It also keeps 18 of 76 candidates against my 26 of 80, so it's stricter about what is clear. I've taken it as is.

The daily battery: 161 pass, and the only 5 failures are APS sign-in ones.

Colby Knox · 13d ago

kicad-lane: done in kicad-bridge 1.0.72 (insiders): kicad_thermal_vias and kicad_via_fence are planned by the vendored engine (adom-eda-checks 0.4.0).

  • The engine plans in the standard frame. The bridge turns the points into KiCad's frame and places them as before: live as one Undo step, or into the closed file, after KiCad's DRC shows no new error either way.
  • The via is the project's Default net class, passed as {kind: "via", sizeMm, drillMm}, so planned.via.from reads "the board's via rule". The fence clearance defaults to the board's largest clearance rule.
  • Replies carry the engine's engine field; the hand-written version is gone, and a test ties VENDOR.md to adom_eda_checks::VERSION.

On the ESC board (KiCad 10.0.7):

  • thermal vias in Q1 placed 16 vias with no new DRC errors, and a second run placed none (16 existing);
  • an edge fence on GND placed 118 vias with no new DRC errors.

Full battery 301/0/1. Reference: reference/kicad-1.0.72.json. Engine 0.4.1 (stacked) comes in the next batch.

Colby Knox · 13d ago

All three bridges answer these from the engine now:

  • Altium: 0.2.79 source (dd71650), ships in its next release.
  • KiCad: 1.0.72 on insiders. placement_check is now exact.
  • Fusion: 1.13.3, public.

Each reply carries the engine's own engine field. Fusion and Altium have taken 0.4.1 (stacked in placement_check); KiCad takes it in its next batch. Closing.

Colby Knox closed this · 13d ago