← Commit history

Set visibility: public

Ray ·957618073e · ·parent 301bf09
1 file changed +18−15
page.json+18−15
@@ -38,25 +38,25 @@         "number": "1",         "name": "CP1",         "type": "bidirectional",-        "description": "Charge pump flying capacitor connection; connect 0.01 \u00b5F capacitor between CP1 and CP2."+        "description": "Charge pump flying capacitor connection; connect 0.01 µF capacitor between CP1 and CP2."       },       {         "number": "2",         "name": "CP2",         "type": "bidirectional",-        "description": "Charge pump flying capacitor connection; connect 0.01 \u00b5F capacitor between CP1 and CP2."+        "description": "Charge pump flying capacitor connection; connect 0.01 µF capacitor between CP1 and CP2."       },       {         "number": "3",         "name": "VCP",         "type": "power_out",-        "description": "High-side gate drive voltage output; bypass with 0.1 \u00b5F 16 V capacitor to ground and 1 M\u03a9 resistor to VM."+        "description": "High-side gate drive voltage output; bypass with 0.1 µF 16 V capacitor to ground and 1 MΩ resistor to VM."       },       {         "number": "4",         "name": "VMA",         "type": "power_in",-        "description": "Bridge A motor power supply input; 8.2 V to 45 V operating range, bypass with 0.1 \u00b5F capacitor to ground."+        "description": "Bridge A motor power supply input; 8.2 V to 45 V operating range, bypass with 0.1 µF capacitor to ground."       },       {         "number": "5",@@ -98,7 +98,7 @@         "number": "11",         "name": "VMB",         "type": "power_in",-        "description": "Bridge B motor power supply input; 8.2 V to 45 V operating range, bypass with 0.1 \u00b5F capacitor to ground."+        "description": "Bridge B motor power supply input; 8.2 V to 45 V operating range, bypass with 0.1 µF capacitor to ground."       },       {         "number": "12",@@ -122,55 +122,55 @@         "number": "15",         "name": "V3P3OUT",         "type": "power_out",-        "description": "3.3 V regulated output; output voltage 3.2 V to 3.4 V at 0 to 1 mA load current, bypass with 0.47 \u00b5F 6.3 V capacitor."+        "description": "3.3 V regulated output; output voltage 3.2 V to 3.4 V at 0 to 1 mA load current, bypass with 0.47 µF 6.3 V capacitor."       },       {         "number": "16",         "name": "nRESET",         "type": "input",-        "description": "Active-low reset input; initializes internal logic and disables H-bridge outputs, internal 100 k\u03a9 pulldown."+        "description": "Active-low reset input; initializes internal logic and disables H-bridge outputs, internal 100 kΩ pulldown."       },       {         "number": "17",         "name": "nSLEEP",         "type": "input",-        "description": "Sleep mode input; logic high for normal operation, logic low for low-power sleep mode with ~10 \u00b5A quiescent current."+        "description": "Sleep mode input; logic high for normal operation, logic low for low-power sleep mode with ~10 µA quiescent current."       },       {         "number": "18",         "name": "nFAULT",         "type": "output",-        "description": "Fault indicator open-drain output; active low during overtemperature (>150\u00b0C) or overcurrent (>3 A) fault condition."+        "description": "Fault indicator open-drain output; active low during overtemperature (>150°C) or overcurrent (>3 A) fault condition."       },       {         "number": "19",         "name": "DECAY",         "type": "input",-        "description": "Decay mode selection input; low for slow decay, open for mixed decay, high for fast decay, internal 130 k\u03a9 pullup and 80 k\u03a9 pulldown."+        "description": "Decay mode selection input; low for slow decay, open for mixed decay, high for fast decay, internal 130 kΩ pullup and 80 kΩ pulldown."       },       {         "number": "20",         "name": "APHASE",         "type": "input",-        "description": "Bridge A phase direction control input; logic high sets AOUT1 high and AOUT2 low, internal 100 k\u03a9 pulldown."+        "description": "Bridge A phase direction control input; logic high sets AOUT1 high and AOUT2 low, internal 100 kΩ pulldown."       },       {         "number": "21",         "name": "AENBL",         "type": "input",-        "description": "Bridge A enable input; logic high to enable bridge A motor driver output, internal 100 k\u03a9 pulldown."+        "description": "Bridge A enable input; logic high to enable bridge A motor driver output, internal 100 kΩ pulldown."       },       {         "number": "22",         "name": "BENBL",         "type": "input",-        "description": "Bridge B enable input; logic high to enable bridge B motor driver output, internal 100 k\u03a9 pulldown."+        "description": "Bridge B enable input; logic high to enable bridge B motor driver output, internal 100 kΩ pulldown."       },       {         "number": "23",         "name": "BPHASE",         "type": "input",-        "description": "Bridge B phase direction control input; logic high sets BOUT1 high and BOUT2 low, internal 100 k\u03a9 pulldown."+        "description": "Bridge B phase direction control input; logic high sets BOUT1 high and BOUT2 low, internal 100 kΩ pulldown."       },       {         "number": "24",@@ -287,5 +287,8 @@     "docs/drv8813pwpr-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file