← Commit history

Set visibility: public

Ray ·c079cc4153 · ·parent 482f9ae
1 file changed +16−13
page.json+16−13
@@ -32,19 +32,19 @@         "number": "1",         "name": "IN1",         "type": "input",-        "description": "TTL/CMOS logic control input for switch 1. Logic '0' \u2264 0.8 V (SW1 OFF), logic '1' \u2265 2.4 V (SW1 ON). Input current \u00b10.5 \u00b5A max."+        "description": "TTL/CMOS logic control input for switch 1. Logic '0' ≤ 0.8 V (SW1 OFF), logic '1' ≥ 2.4 V (SW1 ON). Input current ±0.5 µA max."       },       {         "number": "2",         "name": "D1",         "type": "passive",-        "description": "Analog drain terminal of switch 1. Bidirectional analog signal terminal, \u00b115 V analog range, RDS(on) \u2248 25 \u03a9. Conducts equally well in both directions when ON."+        "description": "Analog drain terminal of switch 1. Bidirectional analog signal terminal, ±15 V analog range, RDS(on) ≈ 25 Ω. Conducts equally well in both directions when ON."       },       {         "number": "3",         "name": "S1",         "type": "passive",-        "description": "Analog source terminal of switch 1. Bidirectional analog signal terminal, \u00b115 V analog range. Continuous current 30 mA max, peak 100 mA (1 ms, 10% DC)."+        "description": "Analog source terminal of switch 1. Bidirectional analog signal terminal, ±15 V analog range. Continuous current 30 mA max, peak 100 mA (1 ms, 10% DC)."       },       {         "number": "4",@@ -62,37 +62,37 @@         "number": "6",         "name": "S4",         "type": "passive",-        "description": "Analog source terminal of switch 4. Bidirectional analog signal terminal, \u00b115 V analog range."+        "description": "Analog source terminal of switch 4. Bidirectional analog signal terminal, ±15 V analog range."       },       {         "number": "7",         "name": "D4",         "type": "passive",-        "description": "Analog drain terminal of switch 4. Bidirectional analog signal terminal, \u00b115 V analog range, RDS(on) \u2248 25 \u03a9."+        "description": "Analog drain terminal of switch 4. Bidirectional analog signal terminal, ±15 V analog range, RDS(on) ≈ 25 Ω."       },       {         "number": "8",         "name": "IN4",         "type": "input",-        "description": "TTL/CMOS logic control input for switch 4. Logic '0' \u2264 0.8 V (SW4 OFF), logic '1' \u2265 2.4 V (SW4 ON)."+        "description": "TTL/CMOS logic control input for switch 4. Logic '0' ≤ 0.8 V (SW4 OFF), logic '1' ≥ 2.4 V (SW4 ON)."       },       {         "number": "9",         "name": "IN3",         "type": "input",-        "description": "TTL/CMOS logic control input for switch 3. Logic '0' \u2264 0.8 V (SW3 OFF), logic '1' \u2265 2.4 V (SW3 ON)."+        "description": "TTL/CMOS logic control input for switch 3. Logic '0' ≤ 0.8 V (SW3 OFF), logic '1' ≥ 2.4 V (SW3 ON)."       },       {         "number": "10",         "name": "D3",         "type": "passive",-        "description": "Analog drain terminal of switch 3. Bidirectional analog signal terminal, \u00b115 V analog range, RDS(on) \u2248 25 \u03a9."+        "description": "Analog drain terminal of switch 3. Bidirectional analog signal terminal, ±15 V analog range, RDS(on) ≈ 25 Ω."       },       {         "number": "11",         "name": "S3",         "type": "passive",-        "description": "Analog source terminal of switch 3. Bidirectional analog signal terminal, \u00b115 V analog range."+        "description": "Analog source terminal of switch 3. Bidirectional analog signal terminal, ±15 V analog range."       },       {         "number": "12",@@ -110,19 +110,19 @@         "number": "14",         "name": "S2",         "type": "passive",-        "description": "Analog source terminal of switch 2. Bidirectional analog signal terminal, \u00b115 V analog range."+        "description": "Analog source terminal of switch 2. Bidirectional analog signal terminal, ±15 V analog range."       },       {         "number": "15",         "name": "D2",         "type": "passive",-        "description": "Analog drain terminal of switch 2. Bidirectional analog signal terminal, \u00b115 V analog range, RDS(on) \u2248 25 \u03a9."+        "description": "Analog drain terminal of switch 2. Bidirectional analog signal terminal, ±15 V analog range, RDS(on) ≈ 25 Ω."       },       {         "number": "16",         "name": "IN2",         "type": "input",-        "description": "TTL/CMOS logic control input for switch 2. Logic '0' \u2264 0.8 V (SW2 OFF), logic '1' \u2265 2.4 V (SW2 ON)."+        "description": "TTL/CMOS logic control input for switch 2. Logic '0' ≤ 0.8 V (SW2 OFF), logic '1' ≥ 2.4 V (SW2 ON)."       }     ],     "provenance": {@@ -186,5 +186,8 @@     "docs/dg412dq-t1-e3-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file