← Commit history

Set visibility: public

Ray ·d5351b29af · ·parent 5c68a34
1 file changed +10−7
page.json+10−7
@@ -38,7 +38,7 @@         "number": "2",         "name": "D1",         "type": "passive",-        "description": "Drain terminal of analog switch 1. Bidirectional analog signal path; RDS(on) typ 45 \u03a9. Analog signal range \u00b115 V with \u00b115 V supplies."+        "description": "Drain terminal of analog switch 1. Bidirectional analog signal path; RDS(on) typ 45 Ω. Analog signal range ±15 V with ±15 V supplies."       },       {         "number": "3",@@ -68,13 +68,13 @@         "number": "7",         "name": "D4",         "type": "passive",-        "description": "Drain terminal of analog switch 4. Bidirectional analog signal path; RDS(on) typ 45 \u03a9."+        "description": "Drain terminal of analog switch 4. Bidirectional analog signal path; RDS(on) typ 45 Ω."       },       {         "number": "8",         "name": "IN4",         "type": "input",-        "description": "Digital control input for switch 4. TTL/CMOS compatible (VIL <= 0.8 V, VIH >= 2.4 V). Input current \u00b11 \u00b5A max."+        "description": "Digital control input for switch 4. TTL/CMOS compatible (VIL <= 0.8 V, VIH >= 2.4 V). Input current ±1 µA max."       },       {         "number": "9",@@ -86,7 +86,7 @@         "number": "10",         "name": "D3",         "type": "passive",-        "description": "Drain terminal of analog switch 3. Bidirectional analog signal path; RDS(on) typ 45 \u03a9."+        "description": "Drain terminal of analog switch 3. Bidirectional analog signal path; RDS(on) typ 45 Ω."       },       {         "number": "11",@@ -104,7 +104,7 @@         "number": "13",         "name": "V+",         "type": "power_in",-        "description": "Positive supply rail. Typically +15 V (dual supply) or up to +25 V (single supply). V+ to V- must not exceed 44 V. Positive supply current I+ 50 \u00b5A max."+        "description": "Positive supply rail. Typically +15 V (dual supply) or up to +25 V (single supply). V+ to V- must not exceed 44 V. Positive supply current I+ 50 µA max."       },       {         "number": "14",@@ -116,7 +116,7 @@         "number": "15",         "name": "D2",         "type": "passive",-        "description": "Drain terminal of analog switch 2. Bidirectional analog signal path; RDS(on) typ 45 \u03a9."+        "description": "Drain terminal of analog switch 2. Bidirectional analog signal path; RDS(on) typ 45 Ω."       },       {         "number": "16",@@ -186,5 +186,8 @@     "docs/dg201bdy-t1-e3-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file