component
CRCW0402270RFKEDHP
Public Made by Adomby adom
VISHAY Global Sourcing Parts, 0402. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.
← Commit history
page.json+177−29@@ -1,8 +1,11 @@ {+ "schema_version": 1,+ "type": "component", "slug": "crcw0402270rfkedhp",+ "title": "CRCW0402270RFKEDHP",+ "brief": "VISHAY Global Sourcing Parts, 0402. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "version": "0.1.0",- "type": "component",- "description": "VISHAY Global Sourcing Parts, 0402. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "license": "CC-BY-SA-4.0", "tags": [ "component", "global sourcing parts",@@ -10,26 +13,6 @@ "factory-2.0.0", "extractor-text" ],- "dependencies": {},- "hero": {- "type": "image",- "path": "docs/hero.png"- },- "files": [- "page.json",- "README.md",- "crcw0402270rfkedhp.kicad_sym",- "crcw0402270rfkedhp.kicad_mod",- "crcw0402270rfkedhp.glb",- "crcw0402270rfkedhp.step",- "crcw0402270rfkedhp.lbr",- "docs/hero.png",- "docs/crcw0402270rfkedhp-datasheet.pdf",- "viewers/symbol.html",- "viewers/footprint.html",- "crcw0402270rfkedhp-hero.glb",- "crcw0402270rfkedhp-hero.overlay.json"- ], "component": { "mpn": "CRCW0402270RFKEDHP", "manufacturer": "VISHAY",@@ -122,12 +105,12 @@ "origin": "footprint origin = pad-pattern centre", "seat": "z = 0", "extents_mm": [- 1,+ 1.0, 0.5, 0.35 ],- "zmin_mm": 0,- "centre_offset_mm": 0,+ "zmin_mm": -0.0,+ "centre_offset_mm": 0.0, "footprint_binding": "identity", "sha256": "91507e5af4251cb4ef38e04889c9b98da29904432bd83786bba13ae9b605eacb", "checked": "2026-10-18",@@ -135,10 +118,175 @@ } ] },- "visibility": "public",- "org": "adom",+ "metadata": {+ "specs": {+ "Manufacturer": "VISHAY",+ "Package": "0402",+ "Category": "Global Sourcing Parts",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "a4bbdbded4d6abb056eb9aa185b5a9aa01b4c308d4d649f22fb6d14c77270b04",+ "rows": [+ {+ "name": "Resistance tolerance (±1 %, code F)",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -1,+ "typ": null,+ "max": 1,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Temperature coefficient of resistance (±100 ppm/K, code K)",+ "symbol": "TCR",+ "kind": "temperature_coefficient",+ "unit": "ppm/K",+ "min": -100,+ "typ": null,+ "max": 100,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Rated dissipation, P70",+ "symbol": "P70",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": null,+ "max": 0.2,+ "conditions": "P70 (rated at 70 °C ambient)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Operating voltage, Umax ACRMS/DC",+ "symbol": "Umax",+ "kind": "recommended_operating",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 50,+ "conditions": "ACRMS/DC",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Permissible voltage against ambient (insulation)",+ "symbol": "Uins",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 75,+ "conditions": "1 min",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Permissible film temperature",+ "symbol": "ϑF max",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 155,+ "conditions": "",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Operating temperature range",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 155,+ "conditions": "",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Max. resistance change at P70 for resistance range |ΔR/R|",+ "symbol": "ΔR/R",+ "kind": "tolerance",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 2,+ "conditions": "at P70, after 1000 h",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Max. resistance change at P70 for resistance range |ΔR/R|",+ "symbol": "ΔR/R",+ "kind": "tolerance",+ "unit": "%",+ "min": null,+ "typ": null,+ "max": 4,+ "conditions": "at P70, after 8000 h",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance for specified power rating",+ "symbol": "Rth",+ "kind": "thermal",+ "unit": "K/W",+ "min": null,+ "typ": null,+ "max": 110,+ "conditions": "required for specified power rating (note 3)",+ "source_page": 1,+ "source": "datasheet"+ }+ ]+ }+ },+ "variants": [],+ "sections": [+ "hero",+ "viewers",+ "readme",+ "breadcrumbs",+ "info"+ ],+ "discovery_triggers": [+ "crcw0402270rfkedhp"+ ],+ "discovery_pitch": "CRCW0402270RFKEDHP (VISHAY) component page: datasheet pinout, KiCad symbol, footprint and 3D.", "author": { "name": "Ray", "email": "[email protected]"- }-}+ },+ "dependencies": {},+ "hero": {+ "type": "image",+ "path": "docs/hero.png"+ },+ "files": [+ "page.json",+ "README.md",+ "crcw0402270rfkedhp.kicad_sym",+ "crcw0402270rfkedhp.kicad_mod",+ "crcw0402270rfkedhp.glb",+ "crcw0402270rfkedhp.step",+ "crcw0402270rfkedhp.lbr",+ "docs/hero.png",+ "docs/crcw0402270rfkedhp-datasheet.pdf",+ "viewers/symbol.html",+ "viewers/footprint.html",+ "crcw0402270rfkedhp-hero.glb",+ "crcw0402270rfkedhp-hero.overlay.json"+ ]+}