← Commit history

Set visibility: public

Ray ·9ba8dfd6de ·2mo ago ·parent 846e9f7
1 file changed +8−5
page.json+8−5
@@ -38,25 +38,25 @@         "number": "2",         "name": "IN",         "type": "input",-        "description": "Control input; activates the power switch when pulled low (shorted to ground via R_IN). Required current capability of input switch typ. 1.6 mA (max 2.4 mA); turn-off current max 30 \u00b5A. Under-voltage shutdown at V_bIN \u2248 2.5-3.5 V."+        "description": "Control input; activates the power switch when pulled low (shorted to ground via R_IN). Required current capability of input switch typ. 1.6 mA (max 2.4 mA); turn-off current max 30 µA. Under-voltage shutdown at V_bIN ≈ 2.5-3.5 V."       },       {         "number": "3",         "name": "Vbb",         "type": "power_in",-        "description": "Positive supply voltage. Operating range 5.5-62 V; absolute max 62 V (48 V for full short-circuit protection); load-dump 70 V. Tab and pin 3 are internally shorted. Integrated series resistor R_bb \u2248 100 \u03a9 in the V_bb line."+        "description": "Positive supply voltage. Operating range 5.5-62 V; absolute max 62 V (48 V for full short-circuit protection); load-dump 70 V. Tab and pin 3 are internally shorted. Integrated series resistor R_bb ≈ 100 Ω in the V_bb line."       },       {         "number": "Tab",         "name": "Vbb",         "type": "power_in",-        "description": "Exposed thermal tab, internally shorted to pin 3 (Vbb). Provides the primary thermal path; must be soldered to Vbb copper for the specified R_thJA (45-55 K/W on 50\u00d750 mm 1.5 mm FR4 with 6 cm\u00b2 copper)."+        "description": "Exposed thermal tab, internally shorted to pin 3 (Vbb). Provides the primary thermal path; must be soldered to Vbb copper for the specified R_thJA (45-55 K/W on 50×50 mm 1.5 mm FR4 with 6 cm² copper)."       },       {         "number": "4",         "name": "IS",         "type": "output",-        "description": "Sense/diagnostic output. In normal operation delivers a current proportional to the load current with ratio k_ILIS \u2248 9000 (I_S = I_L / k_ILIS). In fault conditions (overload, overtemperature, short circuit) sources a defined fault current I_IS,fault \u2248 4.0-7.5 mA. Requires external R_IS (typ. 1 k\u03a9) to signal GND; leave open if unused."+        "description": "Sense/diagnostic output. In normal operation delivers a current proportional to the load current with ratio k_ILIS ≈ 9000 (I_S = I_L / k_ILIS). In fault conditions (overload, overtemperature, short circuit) sources a defined fault current I_IS,fault ≈ 4.0-7.5 mA. Requires external R_IS (typ. 1 kΩ) to signal GND; leave open if unused."       },       {         "number": "5",@@ -126,5 +126,8 @@     "docs/bts6163d-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file