← Commit history

Set visibility: public

Ray ·9fb33f6689 ·2mo ago ·parent e315b48
1 file changed +6−3
page.json+6−3
@@ -32,7 +32,7 @@         "number": "1",         "name": "IN",         "type": "input",-        "description": "Current-controlled input. Activates the power switch when connected to GND (pin1 grounded). On-state input current I_IN(on) \u2248 0.3 mA typ (1 mA max). Input resistance R_I \u2248 1 k\u03a9 (0.5-2.5 k\u03a9). Max input current \u00b115 mA. ESD \u00b11 kV."+        "description": "Current-controlled input. Activates the power switch when connected to GND (pin1 grounded). On-state input current I_IN(on) ≈ 0.3 mA typ (1 mA max). Input resistance R_I ≈ 1 kΩ (0.5-2.5 kΩ). Max input current ±15 mA. ESD ±1 kV."       },       {         "number": "2",@@ -44,7 +44,7 @@         "number": "3",         "name": "OUT",         "type": "output",-        "description": "High-side switched output to the load. On-state resistance R_ON \u2248 1 \u03a9 typ (1.5 \u03a9 max @ 25 \u00b0C). Supports resistive, inductive and capacitive loads with output clamp V_ON(CL) \u2265 60 V during inductive switch-off."+        "description": "High-side switched output to the load. On-state resistance R_ON ≈ 1 Ω typ (1.5 Ω max @ 25 °C). Supports resistive, inductive and capacitive loads with output clamp V_ON(CL) ≥ 60 V during inductive switch-off."       },       {         "number": "4",@@ -114,5 +114,8 @@     "docs/bts4140n-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file