← Commit history

bta08-800bwrg: specified limits as data (metadata.characteristics, 23 rows from the datasheet)

Ray ·1a1c10d88c · ·parent dcd5305
2 files changed +313
README.md+30
@@ -21,6 +21,36 @@ BTA08-800BWRG from STMicroelectronics, in a TO-220AB. Pinout and pin description | Category | Transistors/Thyristors | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Gate trigger voltage (quadrants I-II-III) | VGT |  |  | 1.2 | V |  | 2 |+| Gate non-trigger voltage | VGD | 0.2 |  |  | V | VD = VDRM, RL = 3.3 kΩ, Tj = 125 °C | 2 |+| Gate trigger current (quadrants I-II-III, BW column) | IGT |  |  | 50 | mA | VD = 12 V, RL = 30 Ω | 2 |+| Holding current (BW column) | IH |  |  | 50 | mA | IT = 100 mA | 2 |+| Latching current, quadrants I and III (BW column) | IL |  |  | 70 | mA | IG = 1.2 x IGT, quadrants I-III | 2 |+| Latching current, quadrant II (BW column) | IL |  |  | 80 | mA | IG = 1.2 x IGT, quadrant II | 2 |+| Critical rate of rise of off-state voltage (BW column) | dV/dt |  |  | 1000 | V/µs | VD = 67% VDRM, gate open, Tj = 125 °C | 2 |+| On-state voltage | VTM |  |  | 1.55 | V | ITM = 11 A, tp = 380 µs, Tj = 25 °C | 3 |+| Threshold on-state voltage | VTO |  |  | 0.85 | V | Tj = 125 °C | 3 |+| Dynamic resistance | RD |  |  | 50 | mΩ | Tj = 125 °C | 3 |+| Off-state and reverse leakage current | IDRM/IRRM |  |  | 5 | µA | VDRM = VRRM, Tj = 25 °C | 3 |+| Off-state and reverse leakage current | IDRM/IRRM |  |  | 1 | mA | VDRM = VRRM, Tj = 125 °C | 3 |+| RMS on-state current (TO-220AB Insulated) | IT(RMS) |  |  | 8 | A | full sine wave, Tc = 100 °C | 2 |+| Non repetitive surge peak on-state current | ITSM |  |  | 80 | A | f = 50 Hz, t = 20 ms, full cycle, Tj initial = 25 °C | 2 |+| Non repetitive surge peak on-state current | ITSM |  |  | 84 | A | f = 60 Hz, tp = 16.7 ms, full cycle, Tj initial = 25 °C | 2 |+| I2t value for fusing | I2t |  |  | 36 | A2s | tp = 10 ms | 2 |+| Critical rate of rise of on-state current | dI/dt |  |  | 50 | A/µs | IG = 2 x IGT, tr ≤ 100 ns, f = 120 Hz, Tj = 125 °C | 2 |+| Peak gate current | IGM |  |  | 4 | A | tp = 20 µs, Tj = 125 °C | 2 |+| Average gate power dissipation | PG(AV) |  |  | 1 | W | Tj = 125 °C | 2 |+| Storage junction temperature range | Tstg | -40 |  | 150 | °C |  | 2 |+| Operating junction temperature range | Tj | -40 |  | 125 | °C |  | 2 |+| Junction to case thermal resistance (AC), TO-220AB Insulated | Rth(j-c) |  |  | 2.5 | °C/W | AC, TO-220AB Insulated | 3 |+| Junction to ambient thermal resistance, TO-220AB Insulated | Rth(j-a) |  |  | 60 | °C/W | TO-220AB / TO-220AB Insulated | 3 |+ ## CAD (KiCad official)  - Symbol: `BTA08-800BWRG`
page.json+283
@@ -151,6 +151,289 @@       "Package": "TO-220AB",       "Category": "Transistors/Thyristors",       "Pins": "3"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "a75018e9bb145502",+      "rows": [+        {+          "name": "Gate trigger voltage (quadrants I-II-III)",+          "symbol": "VGT",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.2,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate non-trigger voltage",+          "symbol": "VGD",+          "kind": "electrical",+          "unit": "V",+          "min": 0.2,+          "typ": null,+          "max": null,+          "conditions": "VD = VDRM, RL = 3.3 kΩ, Tj = 125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate trigger current (quadrants I-II-III, BW column)",+          "symbol": "IGT",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 50,+          "conditions": "VD = 12 V, RL = 30 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Holding current (BW column)",+          "symbol": "IH",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 50,+          "conditions": "IT = 100 mA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Latching current, quadrants I and III (BW column)",+          "symbol": "IL",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 70,+          "conditions": "IG = 1.2 x IGT, quadrants I-III",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Latching current, quadrant II (BW column)",+          "symbol": "IL",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 80,+          "conditions": "IG = 1.2 x IGT, quadrant II",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Critical rate of rise of off-state voltage (BW column)",+          "symbol": "dV/dt",+          "kind": "electrical",+          "unit": "V/µs",+          "min": null,+          "typ": null,+          "max": 1000,+          "conditions": "VD = 67% VDRM, gate open, Tj = 125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "On-state voltage",+          "symbol": "VTM",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.55,+          "conditions": "ITM = 11 A, tp = 380 µs, Tj = 25 °C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Threshold on-state voltage",+          "symbol": "VTO",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.85,+          "conditions": "Tj = 125 °C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Dynamic resistance",+          "symbol": "RD",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": null,+          "max": 50,+          "conditions": "Tj = 125 °C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Off-state and reverse leakage current",+          "symbol": "IDRM/IRRM",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 5,+          "conditions": "VDRM = VRRM, Tj = 25 °C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Off-state and reverse leakage current",+          "symbol": "IDRM/IRRM",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VDRM = VRRM, Tj = 125 °C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "RMS on-state current (TO-220AB Insulated)",+          "symbol": "IT(RMS)",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 8,+          "conditions": "full sine wave, Tc = 100 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Non repetitive surge peak on-state current",+          "symbol": "ITSM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 80,+          "conditions": "f = 50 Hz, t = 20 ms, full cycle, Tj initial = 25 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Non repetitive surge peak on-state current",+          "symbol": "ITSM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 84,+          "conditions": "f = 60 Hz, tp = 16.7 ms, full cycle, Tj initial = 25 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "I2t value for fusing",+          "symbol": "I2t",+          "kind": "absolute_maximum",+          "unit": "A2s",+          "min": null,+          "typ": null,+          "max": 36,+          "conditions": "tp = 10 ms",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Critical rate of rise of on-state current",+          "symbol": "dI/dt",+          "kind": "absolute_maximum",+          "unit": "A/µs",+          "min": null,+          "typ": null,+          "max": 50,+          "conditions": "IG = 2 x IGT, tr ≤ 100 ns, f = 120 Hz, Tj = 125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Peak gate current",+          "symbol": "IGM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 4,+          "conditions": "tp = 20 µs, Tj = 125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Average gate power dissipation",+          "symbol": "PG(AV)",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "Tj = 125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage junction temperature range",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Operating junction temperature range",+          "symbol": "Tj",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Junction to case thermal resistance (AC), TO-220AB Insulated",+          "symbol": "Rth(j-c)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 2.5,+          "conditions": "AC, TO-220AB Insulated",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Junction to ambient thermal resistance, TO-220AB Insulated",+          "symbol": "Rth(j-a)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 60,+          "conditions": "TO-220AB / TO-220AB Insulated",+          "source_page": 3,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],