← Commit history

Set visibility: public

Ray ·706c894788 ·10d ago ·parent 7b50e14
1 file changed +7−4
page.json+7−4
@@ -53,19 +53,19 @@         "number": "1",         "name": "G",         "type": "input",-        "description": "Gate control input requiring maximum 10 mA trigger current at gate-to-A1 voltage \u2264 1.3 V to initiate AC current conduction between main terminals A1 and A2."+        "description": "Gate control input requiring maximum 10 mA trigger current at gate-to-A1 voltage ≤ 1.3 V to initiate AC current conduction between main terminals A1 and A2."       },       {         "number": "2",         "name": "A2",         "type": "bidirectional",-        "description": "Main power terminal for bidirectional AC current conduction; rated 6 A RMS; on-state voltage drop \u2264 0.85 V at junction temperature 125\u00b0C."+        "description": "Main power terminal for bidirectional AC current conduction; rated 6 A RMS; on-state voltage drop ≤ 0.85 V at junction temperature 125°C."       },       {         "number": "3",         "name": "A1",         "type": "bidirectional",-        "description": "Main power terminal for bidirectional AC current conduction; rated 6 A RMS; on-state voltage drop \u2264 0.85 V at junction temperature 125\u00b0C."+        "description": "Main power terminal for bidirectional AC current conduction; rated 6 A RMS; on-state voltage drop ≤ 0.85 V at junction temperature 125°C."       }     ],     "provenance": {@@ -145,5 +145,8 @@     "docs/bta06-600swrg-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file