← Commit history
bsp75nta: rebuilt as a full factory component page (was a placeholder)
2 files changed
+652−14
bsp75nta-etched.step+1−1@@ -1,7 +1,7 @@ ISO-10303-21; HEADER; FILE_DESCRIPTION(('Open CASCADE Model'),'2;1');-FILE_NAME('Open CASCADE Shape Model','2026-10-16T17:45:11',('Author'),(+FILE_NAME('Open CASCADE Shape Model','2026-11-13T02:30:33',('Author'),( 'Open CASCADE'),'Open CASCADE STEP processor 7.8','Open CASCADE 7.8' ,'Unknown'); FILE_SCHEMA(('AUTOMOTIVE_DESIGN { 1 0 10303 214 1 1 1 1 }'));
page.json+651−13@@ -3,7 +3,7 @@ "type": "component", "slug": "bsp75nta", "title": "BSP75NTA",- "brief": "Diodes Incorporated Power Distribution Switches, SOT-223-4. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "brief": "Diodes Incorporated Power Distribution Switches, SOT-223-4. Pinout settled in review by an AI reviewer against the manufacturer's datasheet, KiCad symbol/footprint/3D.", "version": "0.2.0", "license": "CC-BY-SA-4.0", "tags": [@@ -103,12 +103,12 @@ "origin": "footprint origin = pad-pattern centre", "seat": "z = 0", "extents_mm": [- 7,+ 7.0, 6.5, 1.7 ],- "zmin_mm": 0,- "centre_offset_mm": 0,+ "zmin_mm": -0.0,+ "centre_offset_mm": 0.0, "footprint_binding": "identity", "sha256": "77ad6dbacc493cb619c728f26d2ddcf461eb0feb6b977b47d01d51e67016f654", "checked": "2026-11-13",@@ -122,12 +122,12 @@ "origin": "footprint origin = pad-pattern centre", "seat": "z = 0", "extents_mm": [- 7,+ 7.0, 6.5, 1.7 ],- "zmin_mm": 0,- "centre_offset_mm": 0,+ "zmin_mm": -0.0,+ "centre_offset_mm": 0.0, "footprint_binding": "identity", "sha256": "2a849fff4427ba6cf065544eaf0df7bdcce751049e9cae66bd33a4b9303e1c46", "checked": "2026-11-13",@@ -152,7 +152,7 @@ ] }, "E": {- "nom_mm": 7,+ "nom_mm": 7.0, "range_mm": [ 6.7, 7.3@@ -189,6 +189,647 @@ "Package": "SOT-223-4", "Category": "Power Management (PMIC)", "Pins": "4"+ },+ "appearance": {+ "contacts": {+ "quote": " Terminals: Matte Tin Finish Weight: 0.112 grams (Approximate)",+ "page": 1,+ "doc": "ds.pdf",+ "plating": "tin"+ },+ "version": 1,+ "datasheet_sha256": "73dfe20e768d7e15576c5ef4306c2b9dafc31b5d1c581222b554a17ce4c52b40"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "73dfe20e768d7e15576c5ef4306c2b9dafc31b5d1c581222b554a17ce4c52b40",+ "rows": [+ {+ "name": "Continuous Drain-Source Voltage",+ "symbol": "VDS",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 60,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Drain-Source Voltage for Short-Circuit Protection",+ "symbol": "VDS(SC)",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 36,+ "conditions": "VIN = 5V",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Drain-Source Voltage for Short-Circuit Protection",+ "symbol": "VDS(SC)",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "VIN = 10V",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Continuous Input Voltage",+ "symbol": "VIN",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.2,+ "typ": null,+ "max": 10,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Peak Input Voltage",+ "symbol": "VIN",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.2,+ "typ": null,+ "max": 20,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Operating Temperature Range",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature Range",+ "symbol": "TSTG",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Power Dissipation",+ "symbol": "PD",+ "kind": "absolute_maximum",+ "unit": "W",+ "min": null,+ "typ": null,+ "max": 1.5,+ "conditions": "TA = +25°C (Note 5)",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Power Dissipation",+ "symbol": "PD",+ "kind": "absolute_maximum",+ "unit": "W",+ "min": null,+ "typ": null,+ "max": 0.6,+ "conditions": "TA = +25°C (Note 6)",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Continuous Drain Current",+ "symbol": "ID",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 1.3,+ "conditions": "VIN = 10V, TA = +25°C (Note 5)",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Continuous Drain Current",+ "symbol": "ID",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 1.1,+ "conditions": "VIN = 5V, TA = +25°C (Note 5)",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Continuous Drain Current",+ "symbol": "ID",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.7,+ "conditions": "VIN = 5V, TA = +25°C (Note 6)",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Continuous Source Current (Body Diode)",+ "symbol": "IS",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 2,+ "conditions": "Note 5",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Pulsed Source Current (Body Diode)",+ "symbol": "IS",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 3.3,+ "conditions": "Note 7",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Unclamped Single Pulse Inductive Energy",+ "symbol": "EAS",+ "kind": "absolute_maximum",+ "unit": "mJ",+ "min": null,+ "typ": null,+ "max": 550,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Load Dump Protection",+ "symbol": "VLOAD_DUMP",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 80,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Electrostatic Discharge (Human Body Model)",+ "symbol": "VESD",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 4000,+ "conditions": "",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Junction to Ambient",+ "symbol": "RθJA",+ "kind": "thermal",+ "unit": "C/W",+ "min": null,+ "typ": null,+ "max": 83,+ "conditions": "Note 5",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Junction to Ambient",+ "symbol": "RθJA",+ "kind": "thermal",+ "unit": "C/W",+ "min": null,+ "typ": null,+ "max": 45,+ "conditions": "Note 7",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Junction to Ambient",+ "symbol": "RθJA",+ "kind": "thermal",+ "unit": "C/W",+ "min": null,+ "typ": null,+ "max": 208,+ "conditions": "Note 6",+ "source_page": 3,+ "source": "datasheet"+ },+ {+ "name": "Drain-Source Clamp Voltage",+ "symbol": "VDS(AZ)",+ "kind": "electrical",+ "unit": "V",+ "min": 60,+ "typ": 70,+ "max": 75,+ "conditions": "ID = 10mA",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Off-State Drain Current",+ "symbol": "IDSS",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.1,+ "max": 3,+ "conditions": "VDS = 12V, VIN = 0V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Off-State Drain Current",+ "symbol": "IDSS",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 3,+ "max": 15,+ "conditions": "VDS = 32V, VIN = 0V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Input Threshold Voltage",+ "symbol": "VIN(TH)",+ "kind": "electrical",+ "unit": "V",+ "min": 1,+ "typ": 2.1,+ "max": null,+ "conditions": "VDS = VGS, ID = 1mA",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Input Current",+ "symbol": "IIN",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 0.7,+ "max": 1.2,+ "conditions": "VIN = 5V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Input Current",+ "symbol": "IIN",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 1.5,+ "max": 2.7,+ "conditions": "VIN = 7V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Input Current",+ "symbol": "IIN",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 4,+ "max": 7,+ "conditions": "VIN = 10V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Static Drain-Source On-State Resistance",+ "symbol": "RDS(ON)",+ "kind": "electrical",+ "unit": "mΩ",+ "min": null,+ "typ": 520,+ "max": 675,+ "conditions": "VIN = 5V, ID = 0.7A",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Static Drain-Source On-State Resistance",+ "symbol": "RDS(ON)",+ "kind": "electrical",+ "unit": "mΩ",+ "min": null,+ "typ": 385,+ "max": 550,+ "conditions": "VIN = 10V, ID = 0.7A",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Current Limit",+ "symbol": "ID(LIM)",+ "kind": "electrical",+ "unit": "A",+ "min": 0.7,+ "typ": 1,+ "max": 1.5,+ "conditions": "VIN = 5V, VDS > 5V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Current Limit",+ "symbol": "ID(LIM)",+ "kind": "electrical",+ "unit": "A",+ "min": 1,+ "typ": 1.8,+ "max": 2.3,+ "conditions": "VIN = 10V, VDS > 5V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Minimum Input Voltage for Overtemperature Protection",+ "symbol": "VPROT",+ "kind": "electrical",+ "unit": "V",+ "min": 4.5,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Thermal Overload Trip Temperature",+ "symbol": "TJT",+ "kind": "electrical",+ "unit": "°C",+ "min": 150,+ "typ": 175,+ "max": null,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Unclamped Single Pulse Inductive Energy, TJ = +25°C",+ "symbol": "EAS",+ "kind": "electrical",+ "unit": "mJ",+ "min": 550,+ "typ": null,+ "max": null,+ "conditions": "ID(ISO) = 0.7A, VDD = 32V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Unclamped Single Pulse Inductive Energy, TJ = +150°C",+ "symbol": "EAS",+ "kind": "electrical",+ "unit": "mJ",+ "min": 200,+ "typ": null,+ "max": null,+ "conditions": "ID(ISO) = 0.7A, VDD = 32V",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Source Drain Voltage",+ "symbol": "VSD",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "VIN = 0V, -ID = 1.4A",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (minimum copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 720,+ "conditions": "Minimum copper area (Note 6), VIN = 5V, TA = +25°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (minimum copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 840,+ "conditions": "Minimum copper area (Note 6), VIN = 10V, TA = +25°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (minimum copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 575,+ "conditions": "Minimum copper area (Note 6), VIN = 5V, TA = +70°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (minimum copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 670,+ "conditions": "Minimum copper area (Note 6), VIN = 10V, TA = +70°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (minimum copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 520,+ "conditions": "Minimum copper area (Note 6), VIN = 5V, TA = +85°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (minimum copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 605,+ "conditions": "Minimum copper area (Note 6), VIN = 10V, TA = +85°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (minimum copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 320,+ "conditions": "Minimum copper area (Note 6), VIN = 5V, TA = +125°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (minimum copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 375,+ "conditions": "Minimum copper area (Note 6), VIN = 10V, TA = +125°C",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (large copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 1140,+ "conditions": "Large copper area (Note 5), VIN = 5V, TA = +25°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (large copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 1325,+ "conditions": "Large copper area (Note 5), VIN = 10V, TA = +25°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (large copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 915,+ "conditions": "Large copper area (Note 5), VIN = 5V, TA = +70°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (large copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 1060,+ "conditions": "Large copper area (Note 5), VIN = 10V, TA = +70°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (large copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 825,+ "conditions": "Large copper area (Note 5), VIN = 5V, TA = +85°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (large copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 955,+ "conditions": "Large copper area (Note 5), VIN = 10V, TA = +85°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (large copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 510,+ "conditions": "Large copper area (Note 5), VIN = 5V, TA = +125°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Maximum Continuous Current (large copper area)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 590,+ "conditions": "Large copper area (Note 5), VIN = 10V, TA = +125°C",+ "source_page": 6,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -226,8 +867,5 @@ "viewers/footprint.html", "bsp75nta-hero.glb", "bsp75nta-hero.overlay.json"- ],- "visibility": "public",- "description": "Diodes Incorporated Power Distribution Switches, SOT-223-4. Pinout settled in review by an AI reviewer against the manufacturer's datasheet, KiCad symbol/footprint/3D.",- "org": "adom"-}+ ]+}