← Commit history

Set visibility: public

Ray ·ffa01d0b2c ·2mo ago ·parent 63ee152
1 file changed +14−11
page.json+14−11
@@ -32,19 +32,19 @@         "number": "1",         "name": "VREF",         "type": "power_out",-        "description": "Internal 3.3 V reference output. Active only when AC or USB input is present. Output current up to 20 mA; 0.1 \u00b5F decoupling capacitor recommended."+        "description": "Internal 3.3 V reference output. Active only when AC or USB input is present. Output current up to 20 mA; 0.1 µF decoupling capacitor recommended."       },       {         "number": "2",         "name": "STAT1",         "type": "output",-        "description": "Charge status output 1 (open-drain). Requires external pullup (\u22651 k\u03a9). VOL \u2264 0.25 V at 5 mA."+        "description": "Charge status output 1 (open-drain). Requires external pullup (≥1 kΩ). VOL ≤ 0.25 V at 5 mA."       },       {         "number": "3",         "name": "STAT2",         "type": "output",-        "description": "Charge status output 2 (open-drain). Requires external pullup (\u22651 k\u03a9). Combined with STAT1 to encode charge state."+        "description": "Charge status output 2 (open-drain). Requires external pullup (≥1 kΩ). Combined with STAT1 to encode charge state."       },       {         "number": "4",@@ -74,19 +74,19 @@         "number": "8",         "name": "MODE",         "type": "input",-        "description": "Power-source selection input. Low = USB mode current limit (defaults to USB charging); High = AC adapter mode (charges at ISET1 rate). VIL \u2248 1 V, VIH \u2248 1.024 V (small hysteresis, ~24 mV)."+        "description": "Power-source selection input. Low = USB mode current limit (defaults to USB charging); High = AC adapter mode (charges at ISET1 rate). VIL ≈ 1 V, VIH ≈ 1.024 V (small hysteresis, ~24 mV)."       },       {         "number": "9",         "name": "CE",         "type": "input",-        "description": "Chip enable input (active high). Logic-level input; VIL \u2264 0.4 V, VIH \u2265 1.4 V. CE-holdoff time 3.3-6.2 ms."+        "description": "Chip enable input (active high). Logic-level input; VIL ≤ 0.4 V, VIH ≥ 1.4 V. CE-holdoff time 3.3-6.2 ms."       },       {         "number": "10",         "name": "ISET1",         "type": "bidirectional",-        "description": "Charge current set point (RSET to VSS) and precharge/termination set point. VSET typ 2.5 V; KSET \u2248 425 for 100 mA-1.5 A range. Also used to monitor charge current."+        "description": "Charge current set point (RSET to VSS) and precharge/termination set point. VSET typ 2.5 V; KSET ≈ 425 for 100 mA-1.5 A range. Also used to monitor charge current."       },       {         "number": "11",@@ -98,19 +98,19 @@         "number": "12",         "name": "TS",         "type": "bidirectional",-        "description": "Battery temperature sense input. Compared against V(LTF)=2.5 V and V(HTF)=0.5 V thresholds using a 100 \u00b5A current source. Connects to a battery-pack NTC thermistor."+        "description": "Battery temperature sense input. Compared against V(LTF)=2.5 V and V(HTF)=0.5 V thresholds using a 100 µA current source. Connects to a battery-pack NTC thermistor."       },       {         "number": "13",         "name": "DPPM",         "type": "input",-        "description": "Dynamic power-path management set point (RDPPM to VSS). Programs the OUT regulation set point via a 100 \u00b5A current source; SF scale factor \u2248 1.150."+        "description": "Dynamic power-path management set point (RDPPM to VSS). Programs the OUT regulation set point via a 100 µA current source; SF scale factor ≈ 1.150."       },       {         "number": "14",         "name": "TMR",         "type": "bidirectional",-        "description": "Timer program input (RTMR to VSS, 30-100 k\u03a9). Sets fast-charge timer via KTMR \u2248 0.36 s/\u03a9. Tie to VREF to disable the safety timer and charge termination."+        "description": "Timer program input (RTMR to VSS, 30-100 kΩ). Sets fast-charge timer via KTMR ≈ 0.36 s/Ω. Tie to VREF to disable the safety timer and charge termination."       },       {         "number": "15",@@ -134,7 +134,7 @@         "number": "18",         "name": "PG",         "type": "output",-        "description": "Power-good status output (open-drain, active low). Requires external pullup (\u22651 k\u03a9). VOL \u2264 0.25 V at 5 mA."+        "description": "Power-good status output (open-drain, active low). Requires external pullup (≥1 kΩ). VOL ≤ 0.25 V at 5 mA."       },       {         "number": "19",@@ -210,5 +210,8 @@     "docs/bq24070rhlr-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file