← Commit history

Set visibility: public

Ray ·c3ef9177a2 · ·parent 2a5ecb0
1 file changed +10−7
page.json+10−7
@@ -32,7 +32,7 @@         "number": "1",         "name": "TXD",         "type": "input",-        "description": "Transmit Data Input from the CAN controller. Internal pull-up (RTXD ~35 k\u03a9 typ, 20-50 k\u03a9) to VIO ensures a defined recessive state if left floating. Logic thresholds are VIL \u2264 0.3\u00d7VVIO and VIH \u2265 0.7\u00d7VVIO. A low level for longer than tto(dom)TXD triggers the TXD dominant time-out and releases the bus to recessive."+        "description": "Transmit Data Input from the CAN controller. Internal pull-up (RTXD ~35 kΩ typ, 20-50 kΩ) to VIO ensures a defined recessive state if left floating. Logic thresholds are VIL ≤ 0.3×VVIO and VIH ≥ 0.7×VVIO. A low level for longer than tto(dom)TXD triggers the TXD dominant time-out and releases the bus to recessive."       },       {         "number": "2",@@ -44,7 +44,7 @@         "number": "3",         "name": "VCC",         "type": "power_in",-        "description": "Main supply voltage, 4.5 V to 5.5 V (nominal 5 V). Recommend a 100 nF decoupling capacitor to GND. Supply current is typ. 50 mA dominant, 2-5 mA recessive, and ~7 \u00b5A in Standby mode. Undervoltage detection threshold Vuvd(VCC) is 2.75-4.5 V; the transceiver disengages from the bus below this."+        "description": "Main supply voltage, 4.5 V to 5.5 V (nominal 5 V). Recommend a 100 nF decoupling capacitor to GND. Supply current is typ. 50 mA dominant, 2-5 mA recessive, and ~7 µA in Standby mode. Undervoltage detection threshold Vuvd(VCC) is 2.75-4.5 V; the transceiver disengages from the bus below this."       },       {         "number": "4",@@ -56,25 +56,25 @@         "number": "5",         "name": "NSIL",         "type": "input",-        "description": "Silent-mode control input, active LOW (ATA6560 only). With STBY = LOW: NSIL = HIGH selects Normal mode, NSIL = LOW selects Silent (receive-only) mode where the transmitter is disabled. Internal pull-up (Rpu 75-175 k\u03a9, typ. 125 k\u03a9) to VIO ensures a defined HIGH state if left open. Microchip recommends keeping NSIL HIGH in Standby to minimize IVIO."+        "description": "Silent-mode control input, active LOW (ATA6560 only). With STBY = LOW: NSIL = HIGH selects Normal mode, NSIL = LOW selects Silent (receive-only) mode where the transmitter is disabled. Internal pull-up (Rpu 75-175 kΩ, typ. 125 kΩ) to VIO ensures a defined HIGH state if left open. Microchip recommends keeping NSIL HIGH in Standby to minimize IVIO."       },       {         "number": "6",         "name": "CANL",         "type": "bidirectional",-        "description": "Low-level CAN bus line. Differential CAN transceiver output/input; driven low in the dominant state and biased to VCC/2 (Normal mode) or to GND (Standby mode). Protected against short-circuit to GND or a positive supply, transient-protected per ISO 7637-2 (-150 V to +100 V), and rated for \u00b18 kV ESD (IEC 61000-4-2) at pin level."+        "description": "Low-level CAN bus line. Differential CAN transceiver output/input; driven low in the dominant state and biased to VCC/2 (Normal mode) or to GND (Standby mode). Protected against short-circuit to GND or a positive supply, transient-protected per ISO 7637-2 (-150 V to +100 V), and rated for ±8 kV ESD (IEC 61000-4-2) at pin level."       },       {         "number": "7",         "name": "CANH",         "type": "bidirectional",-        "description": "High-level CAN bus line. Differential CAN transceiver output/input; driven high in the dominant state and biased to VCC/2 (Normal mode) or to GND (Standby mode). Same short-circuit, transient, and ESD protection as CANL. Connect via the network's 60 \u03a9 differential termination (typically two 60 \u03a9 resistors or 120 \u03a9 at each bus end)."+        "description": "High-level CAN bus line. Differential CAN transceiver output/input; driven high in the dominant state and biased to VCC/2 (Normal mode) or to GND (Standby mode). Same short-circuit, transient, and ESD protection as CANL. Connect via the network's 60 Ω differential termination (typically two 60 Ω resistors or 120 Ω at each bus end)."       },       {         "number": "8",         "name": "STBY",         "type": "input",-        "description": "Standby-mode control input. LOW = Normal (or Silent) mode, HIGH = low-power Standby mode (transmitter and HSC off; only the wake-up comparator monitors the bus). Internal pull-up (Rpu 75-175 k\u03a9, typ. 125 k\u03a9) to VIO puts the device in Standby by default if the pin is left floating. Logic thresholds are VIL \u2264 0.3\u00d7VVIO and VIH \u2265 0.7\u00d7VVIO."+        "description": "Standby-mode control input. LOW = Normal (or Silent) mode, HIGH = low-power Standby mode (transmitter and HSC off; only the wake-up comparator monitors the bus). Internal pull-up (Rpu 75-175 kΩ, typ. 125 kΩ) to VIO puts the device in Standby by default if the pin is left floating. Logic thresholds are VIL ≤ 0.3×VVIO and VIH ≥ 0.7×VVIO."       }     ],     "provenance": {@@ -138,5 +138,8 @@     "docs/ata6560-gaqw-vao-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file