Ray ·33086fb2f6 ·26d ago ·parent 9502adc
1 file changed +6−3
page.json+6−3
@@ -38,13 +38,13 @@         "number": "2",         "name": "RESET",         "type": "output",-        "description": "Active-low, open-drain reset output. Asserts low when VCC falls below the internal threshold (4.1V for the -41 option) and remains asserted for the tDELAY timeout (typ. 450ms for the L40 variant) after VCC recovers above the release threshold. Requires an external pull-up resistor (typical 100k\u03a9). VOL \u2264 0.4V at ISINK = 3.5mA; maximum pin voltage 6.0V."+        "description": "Active-low, open-drain reset output. Asserts low when VCC falls below the internal threshold (4.1V for the -41 option) and remains asserted for the tDELAY timeout (typ. 450ms for the L40 variant) after VCC recovers above the release threshold. Requires an external pull-up resistor (typical 100kΩ). VOL ≤ 0.4V at ISINK = 3.5mA; maximum pin voltage 6.0V."       },       {         "number": "3",         "name": "VCC",         "type": "power_in",-        "description": "Operating voltage input and monitored supply rail. Recommended operating range 0.9V to 5.5V; absolute maximum 6.0V. Typical bypass 100nF ceramic (CIN) to GND. Supply current \u2248 1\u00b5A typ, 2.5\u00b5A max."+        "description": "Operating voltage input and monitored supply rail. Recommended operating range 0.9V to 5.5V; absolute maximum 6.0V. Typical bypass 100nF ceramic (CIN) to GND. Supply current ≈ 1µA typ, 2.5µA max."       }     ],     "provenance": {@@ -130,5 +130,8 @@     "docs/apx803l40-41sa-7-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file