← Commit history
page.json+6−3@@ -38,13 +38,13 @@ "number": "2", "name": "RESET", "type": "output",- "description": "Reset output. Open-drain, active-low. Asserts low whenever VCC falls below the internally fixed threshold (1.7 V for the -17 option) and remains asserted for the reset active timeout (220 ms for the L20 option) after VCC recovers above the release threshold. Requires an external pull-up (typ. 100 k\u03a9 per the typical applications circuit). Absolute max VRESET = 6.0 V; VOL \u2264 0.4 V at ISINK = 3.5 mA."+ "description": "Reset output. Open-drain, active-low. Asserts low whenever VCC falls below the internally fixed threshold (1.7 V for the -17 option) and remains asserted for the reset active timeout (220 ms for the L20 option) after VCC recovers above the release threshold. Requires an external pull-up (typ. 100 kΩ per the typical applications circuit). Absolute max VRESET = 6.0 V; VOL ≤ 0.4 V at ISINK = 3.5 mA." }, { "number": "3", "name": "VCC", "type": "power_in",- "description": "Operating voltage input; also the monitored supply. Operating range 0.9 V to 5.5 V (absolute max 6.0 V). Typical bypass 100 nF to GND per typical applications circuit. Supply current 1 \u00b5A typ, 2.5 \u00b5A max."+ "description": "Operating voltage input; also the monitored supply. Operating range 0.9 V to 5.5 V (absolute max 6.0 V). Typical bypass 100 nF to GND per typical applications circuit. Supply current 1 µA typ, 2.5 µA max." } ], "provenance": {@@ -108,5 +108,8 @@ "docs/apx803l20-17sa-7-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }